26 resultados para joint motion sense
em Scielo Saúde Pública - SP
Resumo:
The aim of this study was to analyze the alterations of arm and leg movements of patients during stroke gait. Joint angles of upper and lower limbs and spatiotemporal variables were evaluated in two groups: hemiparetic group (HG, 14 hemiparetic men, 53 ± 10 years) and control group (CG, 7 able-bodied men, 50 ± 4 years). The statistical analysis was based on the following comparisons (P ≤ 0.05): 1) right versus left sides of CG; 2) affected (AF) versus unaffected (UF) sides of HG; 3) CG versus both the affected and unaffected sides of HG, and 4) an intracycle comparison of the kinematic continuous angular variables between HG and CG. This study showed that the affected upper limb motion in stroke gait was characterized by a decreased range of motion of the glenohumeral (HG: 6.3 ± 4.5, CG: 20.1 ± 8.2) and elbow joints (AF: 8.4 ± 4.4, UF: 15.6 ± 7.6) on the sagittal plane and elbow joint flexion throughout the cycle (AF: 68.2 ± 0.4, CG: 46.8 ± 2.7). The glenohumeral joint presented a higher abduction angle (AF: 14.2 ± 1.6, CG: 11.5 ± 4.0) and a lower external rotation throughout the cycle (AF: 4.6 ± 1.2, CG: 22.0 ± 3.0). The lower limbs showed typical alterations of the stroke gait patterns. Thus, the changes in upper and lower limb motion of stroke gait were identified. The description of upper limb motion in stroke gait is new and complements gait analysis.
Resumo:
This article jointly examines the differences of laboratory versions of the Dutch clock open auction, a sealed-bid auction to represent book building, and a two-stage sealed bid auction to proxy for the “competitive IPO”, a recent innovation used in a few European equity initial public offerings. We investigate pricing, seller allocation, and buyer welfare allocation efficiency and conclude that the book building emulation seems to be as price efficient as the Dutch auction, even after investor learning, whereas the competitive IPO is not price efficient, regardless of learning. The competitive IPO is the most seller allocative efficient method because it maximizes offer proceeds. The Dutch auction emerges as the most buyer welfare allocative efficient method. Underwriters are probably seeking pricing efficiency rather than seller or buyer welfare allocative efficiency and their discretionary pricing and allocation must be important since book building is prominent worldwide.
Resumo:
In the second segment of the antennae of haematophagous reduviids an unusual cave-like organ is found the function os which was investigated in Triatoma infestans. the morphology of the organ makes it difficult to ascribe it to a mechno- or chemoreceptive function, but shows some characteristics shared with thermoreceptors of other animals. The electrical activity of sense cells was recorded in the presence of stimuli that evoke behavioural responses in this species, i.e. warm, CO2, lactic and butyric acids at different concentrations. The three compounds tested failed to evoke a response at all concentrations assayed. Only thermal stimulation evinced a clear modification in the electrical activity of the sense cells.Both the morphological and electrophysiological findings support a thermoreceptive finding, habitat selection and circadian synchronization.
Resumo:
ABSTRACT The interorganizational cooperation, through joint efforts with various actors, allows the high-tech companies to complement resources, especially in R&D projects. Collaborative projects have been identified in many studies as an important strategy to produce complex products and services in uncertain and competitive environments. Thus, this research aims at deepening the understanding of how the development dynamics of a collaborative R&D project in an industry of high technology occur. In order to achieve the proposed objective, the R&D project of the first microcontroller in the Brazilian semiconductor industry was defined as the object of analysis. The empirical choice is justified by the uniqueness of the case, besides bringing a diversity of actors and a level of complementarity of resources that were significant to the success of the project. Given the motivation to know who the actors were and what the main forms of interorganizational coordination were used in this project, interviews were carried out and a questionnaire was also made, besides other documents related to the project. The results presented show a network of nine actors and their roles in the interorganizational collaboration process, as well as the forms of social and temporal overlapping, used in the coordination of collective efforts. Focusing on the mechanisms of temporal and social integration highlighted throughout the study, the inclusion of R&D projects in the typology for interorganizational projects is proposed in this paper, which was also proposed by Jones and Lichtenstein (2008).
Resumo:
OBJECTIVE To analyze the self-care behaviors according to gender, the symptoms of depression and sense of coherence and compare the measurements of depression and sense of coherence according to gender. METHOD A correlational, cross-sectional study that investigated 132 patients with decompensated heart failure (HF). Data were collected through interviews and consultation to medical records, and analyzed using the chi-square and the Student's t tests with significance level of 0.05. Participants were 75 men and 57 women, aged 63.2 years on average (SD = 13.8). RESULTS No differences in self-care behavior by gender were found, except for rest after physical activity (p = 0.017). Patients who practiced physical activity showed fewer symptoms of depression (p<0.001). There were no differences in sense of coherence according to self-care behavior and gender. Women had more symptoms of depression than men (p = 0.002). CONCLUSION Special attention should be given to women with HF considering self-care and depressive symptoms.
Resumo:
Analisa a abordagem do Sense-Making na busca e uso da informação.
Resumo:
Abstract Objective: To evaluate the rectal volume influence on prostate motion during three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Materials and Methods: Fifty-one patients with prostate cancer underwent a series of three computed tomography scans including an initial planning scan and two subsequent scans during 3D-CRT. The organs of interest were outlined. The prostate contour was compared with the initial CT images considering the anterior, posterior, superior, inferior and lateral edges of the organ. Variations in the anterior limits and volume of the rectum were assessed and correlated with prostate motion in the anteroposterior direction. Results: The maximum range of prostate motion was observed in the superoinferior direction, followed by the anteroposterior direction. A significant correlation was observed between prostate motion and rectal volume variation ( p = 0.037). A baseline rectal volume superior to 70 cm3 had a significant influence on the prostate motion in the anteroposterior direction ( p = 0.045). Conclusion: The present study showed a significant interfraction motion of the prostate during 3D-CRT with greatest variations in the superoinferior and anteroposterior directions, and that a large rectal volume influences the prostate motion with a cutoff value of 70 cm3. Therefore, the treatment of patients with a rectal volume > 70 cm3 should be re-planned with appropriate rectal preparation.
Resumo:
In this article I deal with time as a notion of epistemological content associated though with the notion of a subjective consciousness co-constitutive of physical reality. In this phenomenologically grounded approach I attempt to establish a 'metaphysical' aspect of time, within a strictly epistemological context, in the sense of an underlying absolute subjectivity which is non-objectifiable within objective temporality and thus non-susceptible of any ontological designation. My arguments stem, on the one hand, from a version of quantum-mechanical theory (History Projection Operator theory, HPO theory) in view of its formal treatment of two different aspects of time within a quantum context. The discrete, partial-ordering properties (the notions of before and after) and the dynamical-parameter properties reflected in the wave equations of motion. On the other hand, to strengthen my arguments for a transcendental factor of temporality, I attempt an interpretation of some relevant conclusions in the work of J. Eccles ([5]) and of certain results of experimental research of S. Deahaene et al. ([2]) and others.
Resumo:
OBJECTIVE: to evaluate the results of arthroscopic treatment of refractory adhesive capsulitis of the shoulder associated as for improved range of motion after a minimum follow up of six years. METHODS: from August 2002 to December 2004, ten patients with adhesive capsulitis of the shoulder resistant to conservative treatment underwent arthroscopic surgery. One interscalene catheter was placed for postoperative analgesia before the procedure. All were in Phase II, with a minimum follow up of two years. The mean age was 52.9 years (39-66), predominantly female (90%), six on the left shoulder. The time between onset of symptoms and surgical treatment ranged from six to 20 months. Four adhesive capsulitis were found to be primary (40%) and six secondary (60%). RESULTS: the preoperative mean of active anterior elevation was 92°, of external rotation was 10.5° of the L5 level internal rotation; the postoperative ones were 149°, 40° and T12 level, respectively. Therefore, the average gain was 57° for the anterior elevation, 29.5° for external rotation in six spinous processes. There was a significant difference in movements' gains between the pre and post-operative periods (p<0.001). By the Constant Score (range of motion), there was an increase of 13.8 (average pre) to 32 points (average post). CONCLUSION: the arthroscopic treatment proved effective in refractory adhesive capsulitis of the shoulder resistant to conservative treatment, improving the range of joint movements of patients evaluated after a minimum follow up of six years.
Resumo:
A retrospective study of the epidemiological and clinic-pathological aspects of cattle and buffaloes with degenerative joint disease (DJD) was conducted in the state of Pará, Brazil. From 1999 to 2014, eleven cattle and 24 buffaloes were evaluated. All the treated animals with suspected DJD underwent a clinical examination of the musculoskeletal system. In seven cattle and eight buffaloes with clinical signs of the disease postmortem examination was performed. The common clinical signs observed in both species were chronic lameness, stiff gait, postural changes, audible crackles in the affected limb, prolonged recumbency, difficulty in getting up and progressive weight loss. The lesions observed at necropsy were: irregular articular surfaces, erosion of the articular cartilage and the underlying bone tissue, and proliferation of the periarticular bone tissue with formation of osteophytes. The most affected joints in cattle and buffaloes wereof the hind limb. In buffaloes, the main predisposing factor to the onset of DJD was phosphorus deficiency. In cattle, defects of the anatomical conformation of the hind limbs, chronic trauma due to the activities performed, such as semen collection, and advanced age possibly contributed to the emergence of the disease.
Resumo:
This work deals with an hybrid PID+fuzzy logic controller applied to control the machine tool biaxial table motions. The non-linear model includes backlash and the axis elasticity. Two PID controllers do the primary table control. A third PID+fuzzy controller has a cross coupled structure whose function is to minimise the trajectory contour errors. Once with the three PID controllers tuned, the system is simulated with and without the third controller. The responses results are plotted and compared to analyse the effectiveness of this hybrid controller over the system. They show that the proposed methodology reduces the contour error in a proportion of 70:1.
Resumo:
In this paper we present a study of feasibility by using Cassino Parallel Manipulator (CaPaMan) as an earthquake simulator. We propose a suitable formulation to simulate the frequency, amplitude and acceleration magnitude of seismic motion by means of the movable platform motion by giving a suitable input motion. In this paper we have reported numerical simulations that simulate the three principal earthquake types for a seismic motion: one at the epicenter (having a vertical motion), another far from the epicenter (with the motion on a horizontal plane), and a combined general motion (with a vertical and horizontal motion).
Resumo:
Production machines for next generation LSIs such as 4G-DRAMs and for large liquid crystal displays such as 0.5mx0.5m size, and information equipment such as magnetic hard disks and DVDs must have the positioning accuracy of a nano-meter order. To realize such a high degree of the positioning accuracy, not only precision machine elements and mechanisms but also high precision sensors, actuators and controller design techniques becomes crucial. This paper introduces recent topics of precision positioning and motion control technology in Japan.
Resumo:
The objective of the present study was to evaluate incentive spirometers using volume- (Coach and Voldyne) and flow-oriented (Triflo II and Respirex) devices. Sixteen healthy subjects, 24 ± 4 years, 62 ± 12 kg, were studied. Respiratory variables were obtained by respiratory inductive plethysmography, with subjects in a semi-reclined position (45º). Tidal volume, respiratory frequency, minute ventilation, inspiratory duty cycle, mean inspiratory flow, and thoracoabdominal motion were measured. Statistical analysis was performed with Kolmogorov-Smirnov test, t-test and ANOVA. Comparison between the Coach and Voldyne devices showed that larger values of tidal volume (1035 ± 268 vs 947 ± 268 ml, P = 0.02) and minute ventilation (9.07 ± 3.61 vs 7.49 ± 2.58 l/min, P = 0.01) were reached with Voldyne, whereas no significant differences in respiratory frequency were observed (7.85 ± 1.24 vs 8.57 ± 1.89 bpm). Comparison between flow-oriented devices showed larger values of inspiratory duty cycle and lower mean inspiratory flow with Triflo II (0.35 ± 0.05 vs 0.32 ± 0.05 ml/s, P = 0.00, and 531 ± 137 vs 606 ± 167 ml/s, P = 0.00, respectively). Abdominal motion was larger (P < 0.05) during the use of volume-oriented devices compared to flow-oriented devices (52 ± 11% for Coach and 50 ± 9% for Voldyne; 43 ± 13% for Triflo II and 44 ± 14% for Respirex). We observed that significantly higher tidal volume associated with low respiratory frequency was reached with Voldyne, and that there was a larger abdominal displacement with volume-oriented devices.