38 resultados para interferences

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mast cells and eosinophils actively participate in tissue repair and are prominent components of Schistosoma mansoni granulomas. Since pentoxifillyne (PTX) is an immunomodulatory and antifibrotic substance, we aimed to characterize, by morphological techniques, the effect of this drug on fibrosis developed inside murine hepatic schistosomal granulomatous reaction, beyond the quantification of eosinophil and mast cell populations. The drug (1 mg/100 g animal weight) was administrated from 35 to 90 days post-infection, when the animals were killed. The intragranulomatous interstitial collagen network was analyzed by confocal laser scanning microscopy, the number of eosinophils and mast cells was quantified and the results were validated by t-student test. Treatment did not interfere on the granuloma evolution but caused a significant decrease in the total and involutive number of hepatic granulomas (p = 0.01 and 0.001, respectivelly), and in the intragranulomatous accumulation of eosinophils (p = 0.0001). Otherwise, the number of mast cells was not significantly altered (p = 0.9); however, it was positively correlated with the number of granulomatous structures (r = 0.955). In conclusion, PTX does not affect development and collagen deposition in S. mansoni murine granuloma, but decreases the intragranulomatous eosinophil accumulation possibly due to its immunomodulatory capability, interfering in cellular recruitment and/or differentiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a new mathematical equation correction approach for overcoming spectral and transport interferences was proposed. The proposal was applied to eliminate spectral interference caused by PO molecules at the 217.0005 nm Pb line, and the transport interference caused by variations in phosphoric acid concentrations. Correction may be necessary at 217.0005 nm to account for the contribution of PO, since Atotal217.0005 nm = A Pb217.0005 nm + A PO217.0005 nm. This may be easily done by measuring other PO wavelengths (e.g. 217.0458 nm) and calculating the relative contribution of PO absorbance (A PO) to the total absorbance (Atotal) at 217.0005 nm: A Pb217.0005 nm = Atotal217.0005 nm - A PO217.0005 nm = Atotal217.0005 nm - k (A PO217.0458 nm). The correction factor k is calculated from slopes of calibration curves built up for phosphorous (P) standard solutions measured at 217.0005 and 217.0458 nm, i.e. k = (slope217.0005 nm/slope217.0458 nm). For wavelength integrated absorbance of 3 pixels, sample aspiration rate of 5.0 ml min-1, analytical curves in the 0.1 - 1.0 mg L-1 Pb range with linearity better than 0.9990 were consistently obtained. Calibration curves for P at 217.0005 and 217.0458 nm with linearity better than 0.998 were obtained. Relative standard deviations (RSD) of measurements (n = 12) in the range of 1.4 - 4.3% and 2.0 - 6.0% without and with mathematical equation correction approach were obtained respectively. The limit of detection calculated to analytical line at 217.0005 nm was 10 µg L-1 Pb. Recoveries for Pb spikes were in the 97.5 - 100% and 105 - 230% intervals with and without mathematical equation correction approach, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The organic and inorganic forms of soil nitrogen and how they participate in the process of fixation, immobilization and mineralization of ammonium in soils were evaluated, after different periods of incubaton, utilizing two soils, a Lithic Haplustoll and a Typic Eutrorthox. The results obtained permit to suggest that : 1) The method for determination of the ammonium fixing capacity based on the extraction with 2N KC1, is considered to be subject to interferences of other soil fractions capable of retaining ammonium. 2) The increase in exchangeable ammonium content is related to the decrease in amino acids and hydrolyzable ammonium. 3) The immobilization and mineralization processes are still held under mil microbial. The forms more affected by this condition are amino acids and hydrolyzable ammonium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The reversals of Mitsuda's reactions induced by BCG have been objected to based on the possiblem interference of other determination causes of the phenomenon: tuberculous primo-infections, communicants of unsuspected leprosy, revearsals due to other causes, such as anti-diphteric and anti-tetanic vaccination, etc. In order to study the problem, we have used Rhesus monkeys (Macaca mulatta), which were reared in isolation, in an attempt to avoid the referred to interferences. Prior to the experiments, all animals were tested and found negative to radiograph, tuberculin and lepromin tests and were then submitted to the application of BCG vaccine (from 1 to 3 days old), in different doses and by different via. At different times, after the application of BCG, they were again submitted to the radiographic, tuberculin and lepromin tests. In the tables I to IV the experiences were summarised. From the experiments, the following conclusions were reached: 1 - From 12 Rhesus that received BCG 11 showed reversals of the Mitsuda reaction (91.7%). 2 - These reverseals took place both in tests effected shortly after BCG (from 6 days to 2 months), and tests effected much later (from 7 to 12 months after BCG). 3 - Some differences were found in the results, according to the dosis and the application via of the BCG. a) - The testicular and peritonela via (0,02g) were the only that determined strong positive Mitsuda's reactions (+++). b) - By oral via, animals that received high dosis (0.6g and 1.2 g), there resulted uniform and regular reversals, even though of low intensity (+); but from those who got small doses (0.2 g.) one showed no reversals in all tests, and the other presented reversals in the 2nd and 3rd tests only, also with low positivity (+). 4) In the 2nd and 3rd Mitsuda's reactions in the same animals, positivity was always precocious (generally within 48 hours), one getting the impression that there occurs a sensibilization of the animal body by the antigen with the repetition of the tests, even though the intensity of the reaction always remains the same. This precocious reaction (Fernandez type) occurs both shortly and long time after the application of the BCG. Its precocity depends not of the antigen only because the first Mitsuda's reaction after the BCG application occurs after some time and seems not influenced by the control lepromin test effected on the Rhesus before the BCG. 5) On the control group, the animals which received a.a.f. bacilli suspensions (Mycobacterium sp.; M. avium, and M. smegmatis), did not show reverseals of the Mitsuda's reaction. Two Rhesus, however, which received dead BCG (120ºC autoclave 1 hour), one intradermically (0.006 g) and the other orally (1.2 g), did both present reversals of the Mitsuda's reaction, with weak positivity (+). In all animals of the control-group, the allergic reactions were found negative. 6) Strong local inflammatory reactions were observed in the Rhesus that had received living BCG by intradermal via, and in the one submitted to multipunctures, there occurred the formation of a large caseous abcess. 7) The allergic tuberculinic and infratuberculinic reactions appeared dissociated from the Mitsuda's reactions: sometimes they are more precocious, occurring before of the lepromin test; on other occasions they disappear, when the Mitsuda's reactions still persist; and finally, they may be absent, when the latter occur, especially after the oral application of the BCG. 8) In Rhesus which received BCG by testicular and peritonela via, in the infratuberculinic test (0.1 ml of total BCG extract), besides the classic answer, which occurs between 48 and 96 hours, one could observe a delayed answer (15 to 20 days), represented by a non-erythematous nodule, which persists for 11-14 days.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To analyze the reliability and validity of the psychometric properties of the Brazilian version of the instrument for symptom assessment, titled MD Anderson Symptom Inventory - core. Method A cross-sectional study with 268 cancer patients in outpatient treatment, in the municipality of Ijuí, state of Rio Grande do Sul, Brazil. Results The Cronbach’s alpha for the MDASI general, symptoms and interferences was respectively (0.857), (0.784) and (0.794). The factor analysis showed adequacy of the data (0.792). In total, were identified four factors of the principal components related to the symptoms. Factor I: sleep problems, distress (upset), difficulties in remembering things and sadness. Factor II: dizziness, nausea, lack of appetite and vomiting. Factor III: drowsiness, dry mouth, numbness and tingling. Factor IV: pain, fatigue and shortness of breath. A single factor was revealed in the component of interferences with life (0.780), with prevalence of activity in general (59.7%), work (54.9%) and walking (49.3%). Conclusion The Brazilian version of the MD Anderson Symptom Inventory - core showed adequate psychometric properties in the studied population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

X-This work shows an alternative method to copper determination by X-Ray Fluorescence (XRF). Since copper concentration in natural waters is not enough to reach XRF detection limit, a liquid-solid preconcentration procedure was proposed. Glycerin was used to complex the metal increasing its adsorption on activated charcoal. The solid phase was used to XRF determination. Several parameters were evaluated, such as, the complexation pH, the charcoal adsorption limit and the glycerin concentration. The interferences are lead and bismuth and the sensitivities decreased in the order Cu2+, Bi3+ and Pb2+. The advantages of the method are its simplicity, low cost and low spectral interference.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spectrophotometric determination of total protein is used in several areas such as clinical analysis, food science and technology, biochemistry, protein chemistry, physiology. Five spectrophotometric methods are mostly used: biuret, Lowry, Bradford, Smith and UV absorption. In this review a general overview of these methods is presented (interferences, applications); other methodologies are also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Selectivity studies for the determination of Cr(VI) using the catalytic oxidation of the o-dianisidine by hydrogen peroxide showed two distincts situations. In the first, when interferents were studied by a univariate procedure, Cr(III) and Cu(II) cause serious interferences even at the 2:1 proportion, relative to Cr(VI), while Fe(III) interfered at the 15:1 ratio and EDTA at the 10:1 ratio. On the other hand, when a multivariate investigation was performed, Cr(III) did not present any significant principal effects and its significant interaction effects were negative, in contrast to EDTA, that presented positive interaction effects although, like Cr(III), did not show significant interaction effects. In view of the interferent's action it become necessary to separate Cr(VI) by extraction with methylisobutylketone in a chloridric acid medium before its determination in vegetals and in wastewater from a cellulose industry samples. Using this procedure, the method precision is ±0,5% at the 10 ng/mL Cr(VI) concentration level. The detection and quantification limits, calculated by means of absorbance measurements of ten replicates of blank reagents were 1,1 and 3,2 ng/mL, respectively. The results obtained with real samples showed a relative standard deviation between 1,2% and 3,0% relative to their reference values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ELISAs have been applied to pesticide residue analysis due to their high sensitivity and selectivity. However, some ELISAs performance may be affected by matrix components. In this work, ELISA for carbaryl in water samples was checked for interference by naturally occurring fulvic acids. The results suggested that the high fulvic acid concentration (ž³30 mg L-1) and acidic pH conditions (pH 4.0) interfere with the signal detection decreasing the method sensitivity. A dilution of the samples and adjust to pH 8.0 are appropriate to minimize the matrix interferences in the ELISA method. Good correlation between ELISA and HPLC-DAD results was observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work four different analytical methodologies were studied for the determination of iron and titanium in Portland cement. The cement samples were dissolved with hot HCl and HF, being compared Fe and Ti concentrations through four analytical methods: molecular absorption spectrophotometry using the reagents 1,2-hydroxybenzene-3,5-disulfonic acid (Tiron) and the 5-chloro-salicylic acid (CSA), inductively coupled plasma atomic emission spectrometry (ICP-AES) and flame atomic absorption spectrophotometry (FAAS). In the spectrophotometric determinations were studied pH conditions, reagents addition order, interferences, amount of reagents, linear range and stability of the system. In the techniques of ICP-AES and FAAS were studied the best lines, interferences, sensibility and linear range. The obtained results were compared and the agreement was evaluated among the methods for the determination of the metals of interest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the main problems in quantitative analysis of complex samples by x-ray fluorescence is related to interelemental (or matrix) effects. These effects appear as a result of interactions among sample elements, affecting the x-ray emission intensity in a non-linear manner. Basically, two main effects occur; intensity absorption and enhancement. The combination of these effects can lead to serious problems. Many studies have been carried out proposing mathematical methods to correct for these effects. Basic concepts and the main correction methods are discussed here.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Simultaneous electrolytic deposition is proposed for minimization of Cu2+ and Pb2+ interferences on automated determination of Cd2+ by the Malachite Green-iodide reaction. During electrolysis of sample in a cell with two Pt electrodes and a medium adjusted to 5% (v/v) HNO3 + 0.1% (v/v) H2SO4 + 0.5 mol L-1 NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. With 60 s electrolysis time and 0.25 A current, Pb2+ and Cu2+ levels up to 50 and 250 mg L-1 respectively, can be tolerated without interference. With on-line extraction of Cd2+ in anionic resin minicolumn, calibration graph in the 5.00 - 50.0 µg Cd L-1 range is obtained, corresponding to twenty measurements per hour, 0.7 mg Malachite Green and 500 mg KI and 5 mL sample consumed per determination. Results of the determination of Cd in certified reference materials, vegetables and tap water were in agreement with certified values and with those obtained by GFAAS at 95% confidence level. The detection limit is 0.23 µg Cd L-1 and the RSD for typical samples containing 13.0 µg Cd L-1 was 3.85 % (n= 12).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to compare the performances of the L'vov and integrated platforms in order to overcome the interferences found on lead determination in zidovudine by ET AAS. Pyrolysis and atomization temperatures found with integrated platform were 700 and 1400°C, respectively. The characteristic masses were 12.7 ± 1.2 pg with integrated platform and 11.1 ± 1.3 pg with grooved platform. The ratio between the slopes of zidovudine and aqueous curves shows a decrease in the interferences when the L'vov platform is used (bAZT/b aq = 0.97 ± 0.10) and the detection limit found was 0.03 µg.g-1. That ratio was 0.85 ± 0.07 with the integrated platform.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review focuses the development of electrochemical detection systems coupled to capillary electrophoresis. Conductometric, amperometric, voltametric, and potentiometric modes of detection are reviewed. The positioning of the electrodes, interferences of high electric field, and the materials employed in the fabrication and modification of the electrodes are discussed. The advantages of the use of electrochemical detection with capillary electrophoresis, regarding to the sensitivity and selectivity, is exemplified with a large number of applications. Also, the use of electrochemical detection systems in microchip technology is addressed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction and analytical evaluation of a coated graphite Al(III) ion-selective electrode, based on the ionic pair formed between the Al(F)n3-n anion and tricaprylylmethylammonium cation (Aliquat 336S) incorporated on a poly(vinylchloride) (PVC) matrix membrane are described. A thin membrane film of this ionic pair and dibutylphthalate (DBPh) in PVC was deposited directly on a cylindric graphite rod (2 cm length x 0.5 cm diameter) attached to the end of a glass tube using epoxy resin. The membrane solution was prepared by dissolving 40% (m/m) of PVC in 10 mL of tetrahydrofuran following addition of 45% (m/m) of DBPh and 15% (m/m) of the ionic pair. The effect of membrane composition, fluoride concentration, and several concomitants as potential interferences on the electrode response were investigated. The aluminium(III) ion-selective electrode showed a linear response ranging from 1.4 x 10-4 to 1.0 x 10-2 mol L-1, a detection limit of 4.0 x 10-5 mol L-1, aslope of -54.3±0.2mV dec-1 and a lifetime of more than 1 year (over 3000 determinations for each membrane). The slope indicates that the ion-selective electrode responds preferentially to the Al(F)4- species. Application of this electrode for the aluminium(III) determination in stomach anti-acid samples is reported.