44 resultados para in-beam PET

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The present study was designed to assess the occurrence of co-infection or cross-reaction in the serological techniques used for detecting the anti-Leishmania spp., -Babesia canis vogeli and -Ehrlichia canis antibodies in urban dogs from an area endemic to these parasites. METHODS: The serum samples from dogs were tested for the Babesia canis vogeli strain Belo Horizonte antigen and Ehrlichia canis strain São Paulo by immunofluorescence antibody test (IFAT) and by anti-Leishmania immunoglobulin G (IgG) antibody detection to assess Leishmania infection. We used the following four commercial kits for canine visceral leishmaniasis: ELISA, IFAT, Dual Path Platform (DPP) (Bio Manguinhos(r)/FIOCRUZ/MS) and a rK39 RDT (Kalazar Detect Canine Rapid Test; Inbios). RESULTS : Of 96 serum samples submitted to serological assays, 4 (4.2%) were positive for Leishmania as determined by ELISA; 12 (12.5%), by IFAT; 14 (14.6%) by rK39 RDT; and 20 (20.8%), by DPP. Antibodies against Ehrlichia and Babesia were detected in 23/96 (23.9%) and 30/96 (31.2%) samples, respectively. No significant association was identified between the results of tests for detecting Babesia or Ehrlichia and those for detecting Leishmania (p-value>0.05). CONCLUSIONS: In the present study, we demonstrated co-infection with Ehrlichia or Babesia and Leishmania in dogs from Minas Gerais (Brazil); we also found that the serological tests that were used did not cross-react.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and low cost method to determine volatile contaminants in post-consumer recycled PET flakes was developed and validated by Headspace Dynamic Concentration and Gas Chromatography-Flame Ionization Detection (HDC-GC-FID). The analytical parameters evaluated by using surrogates include: correlation coefficient, detection limit, quantification limit, accuracy, intra-assay precision, and inter-assay precision. In order to compare the efficiency of the proposed method to recognized automated techniques, post-consumer PET packaging samples collected in Brazil were used. GC-MS was used to confirm the identity of the substances identified in the PET packaging. Some of the identified contaminants were estimated in the post-consumer material at concentrations higher than 220 ng.g-1. The findings in this work corroborate data available in the scientific literature pointing out the suitability of the proposed analytical method.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An aliphatic-aromatic copolyester of poly(ethylene terephthalate), PET, and poly(ethylene adipate), PEA, PET-co-PEA, was synthesized by the high temperature melt reaction of post-consumer PET and PEA. As observed by NMR spectroscopy, the reaction yielded random copolyesters in a few minutes through ester-interchange reactions, even without added catalyst. The copolyesters obtained in the presence of a catalyst presented higher intrinsic viscosity than that obtained without the addition of catalyst, due to simultaneous polycondensation and ester-interchange reactions. The structure of the aliphatic-aromatic copolyesters obtained in different PET/PEA ratio is random as observed by NMR analysis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Non-H. pylori helicobacters (NHPH) have been demonstrated as gastric spiral-shaped bacteria in specimens obtained from dogs; however, their roles in the pathogenesis of upper gastrointestinal disease have not yet been clearly established. The purpose of this study was to evaluate the prevalence of NHPH DNA in the gastric mucosa of dogs and its association with histopathology. Helicobacter was detected through histopathological techniques, PCR, and FISH analysis from fundic biopsies of twenty dogs with or without signs of gastrointestinal disease. PCR and FISH were based on partial 16S rRNA gene sequences. Nineteen dogs showed mild to marked gastritis in the fundus, and only one dog had a healthy gastric mucosa. NHPH DNA was detected in 18 dogs with gastritis and one with normal gastric mucosa. However, there was no significant correlation between the presence of NHPH DNA and the degree of gastritis. These results show a high prevalence of NHPH DNA in the gastric mucosa of dogs from Venezuela. Further studies are necessary to determine a possible association between a specific NHPH species and the degree of gastritis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cats, as definitive host, play an important role in the transmission of Toxoplasma gondii. This study aimed to establish the seroprevalence of anti-T. gondii immunoglobulins G and M, and determine the frequency of oocysts in the feces of the domestic cat population in Rio de Janeiro, Brazil. We also aimed to study the association between T. gondii infection and age, sex, breed, lifestyle, diet and retroviral infection. A total of 108 cats were included in the study and fecal samples of 54 of those cats were obtained. Only 5.6% of the cats were seropositive for anti-T. gondii immunoglobulins using the indirect hemagglutination test. None of the 54 cats presented oocysts in their fecal samples. Although not statistically significant, males, mixed-breed, free-roaming and cats aged two years and older were found to be more exposed. Age, lifestyle and the use of litter boxes were found to play an important role as risk factors. Anemia and retroviral infections were independent of T. gondii infection. No antibodies were detected in the majority of cats (94.4%), indicating that those cats had never been exposed to the parasite and, therefore, once infected, they could present the risk of shedding large numbers of oocysts into the environment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A recently developed technique, namely multiple beam interference microscopy, has been applied to investigate the morphology of the parasite Toxoplasma gondii for the first time. The interference pattern obtained from the multiple internal reflection of a T. gondii, sandwiched between a glass plate and a cover plate, was focused on the objective of a conventional microscope. Because of the enhance contrast, several details of sub cellular structure and separating compartments are clearly visible. Details reveal the presence of a nucleus, lipid body, dense granule, rhoptry and amylopectin. The wall thickness of the membrane of the lipid body and the amylopectin is of the order of 0.02 µm and can be clearly distinguished with the help of the present technique. The same parasite has also been examined with the help of atomic force microscopy, and because of its thick membrane, the inner structural details were not observed at all. Sub cellular details of T. gondii observed with the present technique have been reported earlier only by low amplification transmission electron microscopy and not by any optical microscopic technique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective To suggest a national value for the diagnostic reference level (DRL) in terms of activity in MBq.kg–1, for nuclear medicine procedures with fluorodeoxyglucose (18F-FDG) in whole body positron emission tomography (PET) scans of adult patients. Materials and Methods A survey on values of 18F-FDG activity administered in Brazilian clinics was undertaken by means of a questionnaire including questions about number and manufacturer of the installed equipment, model and detector type. The suggested DRL value was based on the calculation of the third quartile of the activity values distribution reported by the clinics. Results Among the surveyed Brazilian clinics, 58% responded completely or partially the questionnaire; and the results demonstrated variation of up to 100% in the reported radiopharmaceutical activity. The suggested DRL for 18F-FDG/PET activity was 5.54 MBq.kg–1 (0.149 mCi.kg–1). Conclusion The present study has demonstrated the lack of standardization in administered radiopharmaceutical activities for PET procedures in Brazil, corroborating the necessity of an official DRL value to be adopted in the country. The suggested DLR value demonstrates that there is room for optimization of the procedures and 18F-FDG/PET activities administered in Brazilian clinics to reduce the doses delivered to patients. It is important to highlight that this value should be continually revised and optimized at least every five years.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective To correlate the results of 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) performed with a specific protocol for assessment of breasts with histological/immunohistochemical findings in breast carcinoma patients. Materials and Methods Cross-sectional study with prospective data collection, where patients with biopsy-confirmed breast carcinomas were studied. The patients underwent PET/CT examination in prone position, with a specific protocol for assessment of breasts. PET/CT findings were compared with histological and immunohistochemical data. Results The authors identified 59 malignant breast lesions in 50 patients. The maximum diameter of the lesions ranged from 6 to 80 mm (mean: 32.2 mm). Invasive ductal carcinoma was the most common histological type (n = 47; 79.7%). At PET/CT, 53 (89.8%) of the lesions demonstrated anomalous concentrations of 18F-FDG, with maximum SUV ranging from 0.8 to 23.1 (mean: 5.5). A statistically significant association was observed between higher values of maximum SUV and histological type, histological grade, molecular subtype, tumor diameter, mitotic index and Ki-67 expression. Conclusion PET/CT performed with specific protocol for assessment of breasts has demonstrated good sensitivity and was associated with relevant histological/immunohistochemical factors related to aggressiveness and prognosis of breast carcinomas.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

AbstractThe effective evaluation for the treatment of patients with Ewing tumors depends on the accuracy in the determination of the primary tumor extent and the presence of metastatic disease. Currently, no universally accepted staging system is available to assess Ewing tumors. The present study aimed at discussing the use of PET/CT as a tool for staging, restaging and assessment of therapeutic response in patients with Ewing tumors. In spite of some limitations of PET/CT as compared with anatomical imaging methods, its relevance in the assessment of these patients is related to the capacity of the method to provide further physiological information, which often generates important clinical implications. Currently, the assessment of patients with Ewing tumor should comprise a study with PET/CT combined with other anatomical imaging modalities, such as radiography, computed tomography and magnetic resonance imaging.

Relevância:

40.00% 40.00%

Publicador:

Relevância:

40.00% 40.00%

Publicador:

Resumo:

As novas diretrizes curriculares dos cursos da área da saúde enfatizam a inserção precoce e responsável de acadêmicos nos serviços de saúde permitindo que parcerias entre Universidade e serviço integrem docentes, profissionais da atenção básica e estudantes de graduação, tendo o serviço público de saúde como cenário de práticas. O objetivo deste trabalho é relatar o processo de implementação e descrever as ações desenvolvidas no PET-Saúde UFMS/Sesau2009. Os dados foram coletados a partir da legislação do PET-Saúde, Projeto PET-Saúde UFMS/Sesau2009, súmulas de reuniões dos professores e preceptores, relatórios individuais de acadêmicos, preceptores e tutores. O PET-Saúde configura-se um exercício de multi e interdisciplinaridade como exemplo da integração ensino-serviço-comunidade. As ações deste estudo foram orientadas por duas linhas de pesquisas com foco na promoção da saúde. Dificuldades no desenvolvimento dos projetos foram sentidas pela incongruência de horários e defasagem curricular dos acadêmicos de diferentes séries e de vários cursos, as quais foram sempre corrigidas com alternativas factíveis que possibilitassem a continuidade das ações. Com este trabalho foi possível evidenciar a importância e o impacto positivo da integração ensino-serviço-comunidade na formação profissional dos acadêmicos e no cotidiano dos profissionais envolvidos.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This contribution discusses the nonlinear dynamics of a pin-ended elasto-plastic beam with both kinematic and isotropic hardening. An iterative numerical procedure based on the operator split technique is developed in order to deal with the nonlinearities in the equations of motion. Free and forced responses for harmonic sinusoidal and square wave excitations are investigated. Numerical simulations present many interesting behaviors such as jump phenomena, sensitivity to initial conditions, chaos and transient chaos. These results indicate that there are practical problems in predicting the response of the beam even when periodic steady state response is expected.