50 resultados para fluorescent-quenched peptides

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have characterized, in the Paracoccidioides brasiliensis yeast phase, an exocellular SH-dependent serine proteinase activity against Abz-MKRLTL-EDDnp and analogous fluorescent-quenched peptides, and showed that it is also active against constituents of the basement membrane in vitro. In the present study, we separated the components of P. brasiliensis culture filtrates by electrophoresis and demonstrated that the serine-thiol exocellular proteinase has a diffuse and heterogeneous migration by SDS-PAGE, localizing in a region between 69 and 43 kDa. The hydrolytic activity was demonstrable after SDS-PAGE using buffered agarose overlays of Abz-MKALTLQ-EDDnp, following incubation at 37oC, and detection of fluorescent bands with a UV transilluminator. Hydrolysis was more intense when incubation was carried out at basic pH, and was completely inhibited with 2.5 mM PMSF and partially with sodium 7-hydroxymercuribenzoate (2.5 mM p-HMB), suggesting its serine-thiol nature. A proteolytic band with similar characteristics was observed in conventional gelatin zymograms, but could not be correlated with a silver-stained component. Detection of the serine-thiol proteinase in substrate gels after SDS-PAGE provides a useful way of monitoring purification of the basement membrane degrading enzyme.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A continuous assay using internally quenched fluorescent peptides with the general sequence Abz-peptidyl-(Dnp)P-OH (Abz = ortho-aminobenzoic acid; Dnp = 2,4-dinitrophenyl) was optimized for the measurement of angiotensin I-converting enzyme (ACE) in human plasma and rat tissues. Abz-FRK(Dnp)P-OH, which was cleaved at the Arg-Lys bond by ACE, was used for the enzyme evaluation in human plasma. Enzymatic activity was monitored by continuous recording of the fluorescence (lambdaex = 320 nm and lambdaem = 420 nm) at 37ºC, in 0.1 M Tris-HCl buffer, pH 7.0, with 50 mM NaCl and 10 µM ZnCl2. The assays can be performed directly in the cuvette of the fluorimeter and the hydrolysis followed for 5 to 10 min. ACE measurements in the plasma of 80 healthy patients with Hip-His-Leu and with Abz-FRK(Dnp)P-OH correlated closely (r = 0.90, P < 0.001). The specificity of the assay was demonstrated by the complete inhibition of hydrolysis by 0.5 µM lisinopril or captopril. Abz-FRK(Dnp)P-OH cleavage by ACE was monitored in rat lung, kidney, heart, and liver homogenates in the presence of a cocktail of inhibitors containing trans-epoxy-succinyl-L-leucylamido-(4-guanido)-butene, pepstatin, phenyl-methylsulfonyl fluoride, N-tosyl-L-phenylalanyl-chloromethyl ketone, and N-tosyl-lysyl-chloromethyl ketone to prevent undesirable hydrolysis. ACE activity in lung, heart and kidney homogenates, but not in liver homogenates, was completely abolished by 0.5 µM lisinopril or captopril. The advantages of the method are the procedural simplicity and the high sensitivity providing a rapid assay for ACE determinations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reviews the use of confocal microscopy as it pertains to the identification of G-protein coupled receptors and the study of their dynamic properties in cell cultures and in mammalian brain following their tagging with specific fluorescent ligands. Principles that should guide the choice of suitable ligands and fluorophores are discussed. Examples are provided from the work carried out in the authors' laboratory using custom synthetized fluoresceinylated or BODIPY-tagged bioactive peptides. The results show that confocal microscopic detection of specifically bound fluorescent ligands permits high resolution appraisal of neuropeptide receptor distribution both in cell culture and in brain sections. Within the framework of time course experiments, it also allows for a dynamic assessment of the internalization and subsequent intracellular trafficking of bound fluorescent molecules. Thus, it was found that neurotensin, somatostatin and mu- and delta-selective opioid peptides are internalized in a receptor-dependent fashion and according to receptor-specific patterns into their target cells. In the case of neurotensin, this internalization process was found to be clathrin-mediated, to proceed through classical endosomal pathways and, in neurons, to result in a mobilization of newly formed endosomes from neural processes to nerve cell bodies and from the periphery of cell bodies towards the perinuclear zone. These mechanisms are likely to play an important role for ligand inactivation, receptor regulation and perhaps also transmembrane signaling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simplified fluorescence inhibition microtest (SFIMT) was standardized for the evaluation of antirabies serum neutralizing antibodies based on the rapid fluorescent focus inhibition test (RFFIT) and the fluorescence inhibition microtest (FIMT). The simplified test showed reproductibility similar to that of the FIMT with advantages as easier executation and quicker reading. A simple pre-treatment of Brazilian microplates produced for immune enzymatic assays (PROSIL) gave equivalent results and substantial coast reduction, in relation to imported plates (DIFCO). The simplified test can be easily implemented in less sophisticated laboratories, as alternative to the mouse serum neutralization test, still the most largely employed in Brazil, or even to others as RFFIT and FIMT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anti-RESA/Pf155 antibodies were assayed in sera of individuals from three localities (Laranjal do Jari, Vila Padaria and Vila Paraíso) in the State of Amapá, Brazil, during the long-rains and short-rains seasons. All of these had negative blood smears for malaria. Most of the sera collected were positive in Indirect Fluorescent Antibody (IFA) with P. falciparum parasites, with no seasonal variation. A high percentage of these sera (62% to 100%) was RESA positive by Modified Indirect Fluorescent Antibody (MIFA), with a significant (p < 0.05) increase of geometric mean titers during the short-rains season, when the transmission of the disease is highest. ELISA with three repetitive RESA peptides (EENV)3 (4x3), (EENVEHDA)2 (8x2) and (DDEHVEEPTVA)2(11x2) did not reveal statistically significant seasonal variations, although a small enhancement of positivity was observed in V. Padaria (15.3 to 38.8%) in the short-rains season with the 8x2 peptides, and with 4x3 and 8x2 peptides in V. Paraíso, with a decrease in 11x2. MIFA titers appeared to be correlated mainly to the peptide 4x3 and it was the immunodominant in the three localities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main serological marker for the diagnosis of recent toxoplasmosis is the specific IgM antibody, along with IgG antibodies of low avidity. However, in some patients these antibodies may persist long after the acute/recent phase, contributing to misdiagnosis in suspected cases of toxoplasmosis. In the present study, the diagnostic efficiency of ELISA was evaluated, with the use of peptides derived from T. gondii ESA antigens, named SAG-1, GRA-1 and GRA-7. In the assay referred to, we studied each of these peptides individually, as well as in four different combinations, as Multiple Antigen Peptides (MAP), aiming to establish a reliable profile for the acute/recent toxoplasmosis with only one patient serum sample. The diagnostic performance of the assay using MAP1, with the combination of SAG-1, GRA-1 and GRA-7 peptides, demonstrated better discrimination of the acute/recent phase from non acute/recent phase of toxoplasmosis. Our results show that IgM antibodies to MAP1 may be useful as a serological marker, enhancing the diagnostic efficiency of the assay for acute/recent phase of toxoplasmosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Sporothrix schenckii is a thermal dimorphic pathogenic fungus causing a subcutaneous mycosis, sporotrichosis. Nitrocoumarin represents a fluorogenic substrate class where the microbial nitroreductase activity produces several derivatives, already used in several other enzyme assays. The objective of this study was the analysis of 6-nitrocoumarin (6-NC) as a substrate to study the nitroreductase activity in Sporothrix schenckii. Methods Thirty-five samples of S. schenckii were cultivated for seven, 14 and 21 days at 35 °C in a microculture containing 6-nitrocoumarin or 6-aminocoumarin (6-AC) dissolved in dimethyl sulfoxide or dimethyl sulfoxide as a negative control, for posterior examination under an epifluorescence microscope. The organic layer of the seven, 14 and 21-day cultures was analyzed by means of direct illumination with 365 nm UV light and by means of elution on G silica gel plate with hexane:ethyl acetate 1:4 unveiled with UV light. Results All of the strains showed the presence of 6-AC (yellow fluorescence) and 6-hydroxylaminocoumarin (blue fluorescence) in thin layer chromatography, which explains the green fluorescence observed in the fungus structure. Conclusion The nitroreductase activity is widely distributed in the S. schenckii complex and 6-NC is a fluorogenic substrate of easy access and applicability for the nitroreductase activity detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyzed the kinetics of cytokine production by mononuclear cells from 17 patients who had been treated for paracoccidioidomycosis, using the stimulus of gp43 peptide groups (43kDa glycoprotein of Paracoccidioides brasiliensis) at 0.1 and 1µM, gp43 (1µg/ml) and crude Paracoccidioides brasiliensis antigen (PbAg; 75µg/ml). IFN-gamma production was a maximum at 144 hours in relation to the G2 and G8 peptide groups at 1µM and was greatest at 144 hours when stimulated by gp43 and by PbAg. The maximum TNF-alpha production was at 144 hours for the G2 group (0.1µM) and for gp43. IL-10 production was highest after 48 and 72 hours for G7 and G6 at 1µM, respectively. We also suggest the best time for analysis of IL4 production. These results may contribute towards future studies with gp43 peptides and encourage further investigations with the aim of understanding the influence of these peptides on the production of inflammatory and regulatory cytokines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of Cyclosporin A (CyA) blood concentration is imperative in solid organ transplantation in order to achieve maximal immunosuppression with the least side effects. We compared the results of whole blood concentrations of CyA in 50 blood samples simultaneously evaluated by the fluorescent polarization immune assay (TDx) and the enzymatic competitive immune assay (EMIT 2000). There was a strong correlation between both kits for any range of CyA blood concentration (R=0.99, p<0.001). The within-run and between-days coefficient of variation were less than 4% for both assays. The cost for each CyA measurement was 50% lower for the EMIT assay when compared to the TDx assay. We concluded that the EMIT is as accurate as the TDx in measuring CyA blood concentration and has the advantage of a lower cost, as well as the possibility of widespread access to the EMIT methodology in contrast to the TDx equipment, allowing the laboratory to perform several routines within a working day.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blood sampling on filter paper is a current practice seroepidemiological studies by indirect fluorescent antibody test (IFAT). There is, however, scant comparative information about the use of bloodspot eluates for detection of malarial IgG antibodies simultaneously by IFAT and enzyme immunoassay (ELISA). Here we report data obtained by both serological methods done on 219 bloodspot eluate samples collected in a rural community in Brazilian Amazon Basin (Alto Paraíso, Ariquemes municipality) where malaria is endemic. Plasmodium falciparum and P. vivax thick smear antigens were used in the IFAT; a detergent-soluble P. falciparum antigen was prepared for ELISA. Substantial agreement of results (Kappa coefficient k = 0.686) was observed when P. falciparum antigen was used in both tests, and IFAT titers were found to be strongly correlated ELISA antibody units (Spearman correlation coeficient rs = 0.818, p < 0.0001). Only moderate agreement (k = 0.467) between IFAT with P. vivax antigen and ELISA with P. falciparum antigen was observed. Spearman correlation coefficient value between quantitative results (IFAT titers and ELISA antibody units) in this case was numerically lowe (rs = 0.540, p < 0.0001). Our results suggest that, with P. falciparum antigen, both IFAT and ELISA performed on bloodspot eluates are equivalent for seropidemiological purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiple antigen peptide systems (MAPs) allow the incorporation of various epitopes in to a single synthetic peptide immunogen. We have characterized the immune response of BALB/c mice to a series of MAPs assembled with different B and T cell epitopes derived from the Plasmodium vivax circumsporozoite (CS) protein. A B-cell epitope from the central repeat domain and two T-cell epitopes from the amino and carboxyl flanking regions were used to assembled eight different MAPs. An additional universal T cell epitope (ptt-30) from tetanus toxin protein was included. Immunogenicity in terms of antibody responses and in vitro T lymphocyte proliferation was evaluated. MAPs containing B and T cell epitopes induced high titers of anti-peptides antibodies, which recognized the native protein on sporozoites as determined by IFAT. The antibody specificity was also determined by a competitive inhibition assay with different MAPs. A MAP containing the B cell epitope (p11) and the universal epitope ptt-30 together with another composed of p11 and the promiscuous T cell epitope (p25) proved to be the most immunogenic. The strong antibody response and specificity for the cognate protein indicates that further studies designed to assess the potential of these proteins as human malaria vaccine candidates are warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluorescent (acridine orange) microscopical examination of capillary centrifuged blood (quantitative buffy coat [QBC®] analysis) and Giemsa stained thick blood smears (GTS) were compared for diagnosis of malaria in blood specimens from adults living in malaria transmission areas of the States of Bolivar and Amazonas in southeastern and south Venezuela, respectively. Of a total of 198 GTS examined, 95 subjects (48%) showed parasitaemia. Among the 95 blood films with a positive GTS, 94 were judged positive by the QBC. However, positive QBC tubes were found in 29 out of 103 blood specimens with a negative GTS. Thus, relative to a GTS standard, the sensitivity and specificity of the QBC-test was 99.2% and 72%, respectively. Young trophozoites of Plasmodium vivax and P. falciparum could not be distinguished with certainty. It is confirmed that the QBC offers many advantages compared with the standard diagnosis of malaria parasites, specifically in the speed of staining and ease of interpretation. However, in places where P. falciparum and P. vivax occur, species and stage differentiation should be confirmed with the GTS.