30 resultados para fluorescence polarization
em Scielo Saúde Pública - SP
Resumo:
INTRODUCTION: Peak and trough serum concentrations of vancomycin were determined in term newborn infants with confirmed or suspected Staphylococcus sp sepsis by high performance liquid chromatography and flourescence polarization immunoassay. OBJECTIVE: To statistically compare the results of the high performance liquid chromatography and flourescence polarization immunoassay techniques for measuring serum vancomycin concentrations. METHODS: Eighteen peak and 20 trough serum samples were assayed for vancomycin concentrations using high performance liquid chromatography and flourescence polarization immunoassay from October 1995 to October 1997. RESULTS: The linear correlation coefficients for high performance liquid chromatography and flourescence polarization immunoassay were 0.27 (peak, P = 0.110) and 0.26 (trough, P = 0.1045) respectively, which were not statistically significant. CONCLUSION: There was wide variation in serum vancomycin concentrations determined by high performance liquid chromatography as compared with those determined by flourescence polarization immunoassay. There was no recognizable pattern in the variability; in an apparently random fashion, the high performance liquid chromatography measurement was sometimes substantially higher than the flourescence polarization immunoassay measurement, and at other times it was substantially lower.
Resumo:
A prospective study was conducted to determine if standardized vancomycin doses could produce adequate serum concentrations in 25 term newborn infants with sepsis. Purpose: The therapeutic response of neonatal sepsis by Staphylococcus sp. treated with vancomycin was evaluated through serum concentrations of vancomycin, serum bactericidal titers (SBT), and minimum inhibitory concentration (MIC). METHOD: Vancomycin serum concentrations were determined by the fluorescence polarization immunoassay technique , SBT by the macro-broth dilution method, and MIC by diffusion test in agar . RESULTS: Thirteen newborn infants (59.1%) had adequate peak vancomycin serum concentrations (20--40 mg/mL) and one had peak concentration with potential ototoxicity risk (>40 µg/mL). Only 48% had adequate trough concentrations (5--10 mg/mL), and seven (28%) had a potential nephrotoxicity risk (>10 µg/mL). There was no significant agreement regarding normality for peak and trough vancomycin method (McNemar test : p = 0.7905). Peak serum vancomycin concentrations were compared with the clinical evaluation (good or bad clinical evolution) of the infants, with no significant difference found (U=51.5; p=0.1947). There was also no significant difference between the patients' trough concentrations and good or bad clinical evolution (U = 77.0; p=0.1710). All Staphylococcus isolates were sensitive to vancomycin according to the MIC. Half of the patients with adequate trough SBT (1/8), also had adequate trough vancomycin concentrations and satisfactory clinical evolution. CONCLUSIONS: Recommended vancomycin schedules for term newborn infants with neonatal sepsis should be based on the weight and postconceptual age only to start antimicrobial therapy. There is no ideal pattern of vancomycin dosing; vancomycin dosages must be individualized. SBT interpretation should be made in conjunction with the patient's clinical presentation and vancomycin serum concentrations. Those laboratory and clinical data favor elucidation of the probable cause of patient's bad evolution, which would facilitate drug adjustment and reduce the risk of toxicity or failing to achieve therapeutic doses.
Resumo:
A simple low-cost flow cell was developed, built and optimized in order to observe dynamic interfacial tension of continuous flow systems. Distinct materials can be used in one of the cell walls in order to observe the intermolecular forces between the flowing liquid and the chemical constitution of the walls. The fluorescence depolarization was evaluated using Rhodamine B as fluorescent probe seeded in ethylene glycol. The effects of the positioning angles on the data acquired across the cell are reported. The reproducibility of the data was evaluated with a spectrometer assembled in-house and the relative standard deviation was below 3%.
Resumo:
A modification of the indirect fluorescence test (IFT) for serological diagnosis of Paracoccidioidomycosis is described in which formolized budding forms (yeast cells) of the fungus Paracoccidioides brasiliensis are used as antigen. A further modification introduced is a less eiaborate technical procedure of the test without lowering the sensitivity of the reaction. The test may be considered as adequateiy accurate and easy to perform in any laboratory with immunofluorescence facilities.
Resumo:
Confocal scanning fluorescence microscopy has become widely used in cell biology and pathology. In conjunction with monoclonal antibodies it may turn out to be a powerful diagnostic tool that also enables detailed studies of tissue forms of Trypanosoma cruzi.
Resumo:
Evaluation of Cyclosporin A (CyA) blood concentration is imperative in solid organ transplantation in order to achieve maximal immunosuppression with the least side effects. We compared the results of whole blood concentrations of CyA in 50 blood samples simultaneously evaluated by the fluorescent polarization immune assay (TDx) and the enzymatic competitive immune assay (EMIT 2000). There was a strong correlation between both kits for any range of CyA blood concentration (R=0.99, p<0.001). The within-run and between-days coefficient of variation were less than 4% for both assays. The cost for each CyA measurement was 50% lower for the EMIT assay when compared to the TDx assay. We concluded that the EMIT is as accurate as the TDx in measuring CyA blood concentration and has the advantage of a lower cost, as well as the possibility of widespread access to the EMIT methodology in contrast to the TDx equipment, allowing the laboratory to perform several routines within a working day.
Resumo:
PURPOSE: Williams-Beuren syndrome is a rare multiple anomalies/mental retardation syndrome caused by deletion of contiguous genes at chromosome region 7q11.23. The aim of this work was to determine the frequency and the types of renal and urinary tract anomalies in 20 patients with Williams-Beuren syndrome. METHODS: The fluorescence in situ hybridization test using a LSI Williams syndrome region DNA probe was performed for all 20 patients to confirm the diagnosis of Williams-Beuren syndrome. A prospective study was performed in order to investigate renal and urinary aspects using laboratory assays to check renal function, ultrasonography of the kidneys and urinary tract, voiding cystourethrogram and urodynamics. RESULTS: Deletion of the elastin gene (positive fluorescence in situ hybridization test) was found in 17 out of 20 patients. Renal alterations were diagnosed in 5 of 17 (29%) the patients with the deletion and in 1 of 3 patients without the deletion. Fourteen patients with the deletion presented dysfunctional voiding. Arterial hypertension was diagnosed in 3 patients with deletions and 1 of these presented bilateral stenosis of the renal arteries. CONCLUSIONS: Due to the high incidence of renal and urinary abnormalities in Williams-Beuren syndrome, performing a systematic laboratory and sonographic evaluation of the patients is recommended.
Resumo:
OBJECTIVE: To evaluate the cardiovascular findings and clinical follow-up of patients with Williams-Beuren syndrome. METHODS: We studied 20 patients (11 males, mean age at diagnosis: 5.9 years old), assessed for cardiovascular abnormalities with electrocardiography and Doppler echocardiography. Fluorescence in situ hybridization (FISH) was used to confirm the diagnosis of the syndrome. RESULTS: Elastin gene locus microdeletion was detected in 17 patients (85%) (positive FISH), and in 3 patients deletion was not detected (negative FISH). Sixteen patients with a positive FISH (94%) had congenital cardiovascular disease (mean age at diagnosis: 2,3 years old). We observed isolated (2/16) supravalvular aortic stenosis and supravalvular aortic stenosis associated (11/16) with pulmonary artery stenosis (4/11); mitral valve prolapse (3/11); bicuspid aortic valve (3/11); aortic coarctation (2/11), thickened pulmonary valve (2/11); pulmonary valvular stenosis (1/11); supravalvular pulmonary stenosis (1/11); valvular aortic stenosis (1/11); fixed subaortic stenosis (1/11); pulmonary artery stenosis (2/16) associated with pulmonary valvar stenosis (1/2) and with mitral valve prolapse (1/2); and isolated mitral valve prolapse (1/16). Four patients with severe supravalvular aortic stenosis underwent surgery (mean age: 5.7 years old), and 2 patients had normal pressure gradients (mean follow-up: 8.4 years). CONCLUSION: A detailed cardiac evaluation must be performed in all patients with Williams-Beuren syndrome due to the high frequency of cardiovascular abnormalities.
Resumo:
Fluorescence flow cytometry was employed to assess the potential of a vital dye, hydroethiedine, for use in the detection and monitoring of the viability of hemoparasites in infected erythrocytes, using Babesia bovis as a model parasite. The studies demonstrated that hydroethidine is taken up by B. bovis and metabolically converted to the DNA binding fluorochrone, ethidium. Following uptake of the dye, erythrocytes contamine viable parasites were readily distinguished and quantitated. Timed studies with the parasiticidal drug, Ganaseg, showed that it is possible to use the fluorochrome assay to monitor the effects of the drug on the rate of replication and viability of B. bovis in culture. The assay provides a rapid method for evaluation of the in vitro effect of drugs on hemoparasites and for analysis of the effect of various components of the immune response, such as lymphokines, monocyte products, antibodies, and effector cells (T, NK, LAK, ADCC) on the growth and viability of intraerythrocytic parasites.
Resumo:
This study evaluated the tolerance of mango cultivars 'Haden', 'Palmer', 'Tommy Atkins' and 'Uba' grafted on rootstock 'Imbú' to salt stress using chlorophyll fluorescence. Plants were grown in modified Hoagland solution containing 0, 15, 30, and 45 mmol L-1 NaCl. At 97 days the parameters of the chlorophyll fluorescence (F0, Fm, Fv, F0/Fm, Fv/Fm, Fv'/Fm', ΦPSII = [(Fm'-Fs)/(Fm')], D = (1- Fv'/Fm') and ETR = (ΦPSII×PPF×0,84×0,5) were determined. At 100 days, the leaf emission and leaf area, toxicity and leaf abscission indexes were determined. In all cultivars evaluated, in different degree, there were decreases in photochemical efficiency of photosystem II, enhanced concentrations from 15 mmol L-1 NaCl. The decreases in the potential quantum yield of photosystem II (Fv/Fm) were 27.9, 18.7, 20.5, and 27.4%, for cultivars 'Haden', 'Palmer', 'Tommy Atkins', and 'Uba', respectively, when grown in 45 mmol L-1 NaCl. It was found decreases in leaf emission and mean leaf area in all cultivars from 15 mmol L-1 NaCl. There were increases in leaf toxicity of 33.0, 67.5, 41.6 and 80.8% and in leaf abscission of 71.8, 29.2, 32.5, and 67.9% for the cultivars 'Haden', 'Palmer', 'Tommy Atkins', and 'Uba' respectively, when grown in 45 mmol L-1 NaCl. Leaf toxicity and leaf abscission were not observed in 15 mmol L-1 NaCl. The decrease in Fv/Fm ratio were accompanied by decreasing in leaf emission and increased leaf toxicity index, showing, therefore, the potential of chlorophyll fluorescence in the early detection of salt stress in mango tree.
Resumo:
Molecular probe techniques have made important contributions to the determination of microstructure of surfactant assemblies such as size, stability, micropolarity and conformation. Conductivity and surface tension were used to determine the critical aggregation concentration (cac) of polymer-surfactant complexes and the critical micellar concentration (cmc) of aqueous micellar aggregates. The results are compared with those of fluorescent techniques. Several surfactant systems were examined, 1-butanol-sodium dodecylsulfate (SDS) mixtures, solutions containing poly(ethylene oxide)-SDS, poly(vinylpyrrolidone)-SDS and poly(acrylic acid)-alkyltrimethylammonium bromide complexes. We found differences between the cac and cmc values obtained by conductivity or surface tension and those obtained by techniques which use hydrophobic probe.
Resumo:
X-This work shows an alternative method to copper determination by X-Ray Fluorescence (XRF). Since copper concentration in natural waters is not enough to reach XRF detection limit, a liquid-solid preconcentration procedure was proposed. Glycerin was used to complex the metal increasing its adsorption on activated charcoal. The solid phase was used to XRF determination. Several parameters were evaluated, such as, the complexation pH, the charcoal adsorption limit and the glycerin concentration. The interferences are lead and bismuth and the sensitivities decreased in the order Cu2+, Bi3+ and Pb2+. The advantages of the method are its simplicity, low cost and low spectral interference.
Resumo:
An analytical study based on extraction with acetonitrile-water, immunoaffinity column cleanup, and HPLC/fluorescence detection for separation and identification of ochratoxin A in coriander was carried out. Validation of the applied methodology was done through accuracy and precision studies. Homogenized samples of coriander were spiked in triplicate with ochratoxin A at 0.5, 1.0, 2.0, and 5.0 µg/kg levels. Recovery values were in the range of 98% for a fortification level at 0.5 µg/kg to 109.1% at 1.0 µg/kg. Application to coriander samples available in Portuguese markes showed no contamination with ochratoxin A.
Resumo:
Here we report the validation of a derivatization method that makes use of fluorescamine as a selective reactant for the quantitative analysis of peptide and protein drugs in the dissolution profile from depot formulations. Typical current methods require separation of the nano/microparticles and time-consuming chromatographic runs. In this study we report a method which can be conducted without the need for complete physical separation of the particles or removal of the unreacted probe. This method was used here for the analysis of the release profile of octreotide in a depot formulation, with results in excellent agreement with reported chromatographic assays.