19 resultados para flow field

em Scielo Saúde Pública - SP


Relevância:

70.00% 70.00%

Publicador:

Resumo:

An experimental study was conducted in a pump-turbine model in pumping mode, in order to characterize the flow field structure in the region between stay and guide vanes, using mainly the laser-Doppler anemometry in a two-color and back-scattered light-based system. The structure of the steady and unsteady flow was analyzed. The measurements were performed at three operation points. The obtained data provide appropriate boundary conditions and a good base of validation for numerical codes, and for the understanding of main loss mechanisms of this complex flow.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The unsteady, viscous, supersonic flow over a spike-nosed body of revolution is numerically investigated by solving the Navier-Stokes equations. The time-accurate computations are performed employing an implicit algorithm based on the second-order time-accurate LU-SGS scheme with the incorporation of a subiteration procedure to maintain time accuracy. The characteristics of the flow field for a Mach number of 3.0, Reynolds number of 7.87 x 10(6)/m, and angles of attack of 5 and 10 degrees are described. Self-sustained asymmetric shock wave oscillations were observed in the numerical computations for these angles of attack. The main characteristic of the flow field, as well as its influence on drag coefficient is discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hemolytic profile of an artificial device chronically implanted in the cardiovascular system may represent the difference between the success and failure in its long-term performance. Last decades have witnessed efforts on the development of methods capable of predicting red blood cell damage in artificial organs. However, all of them have had limited success to predict hemolysis. The primary cause of this problem is that such models do not take into consideration structures of turbulent flow. The present paper demonstrates that microscopic measurable occurrences of the turbulent flow may be linked to red blood cell trauma. This study suggests that if the smallest turbulent eddies dimension is under 10 m m hemolysis is not dependent on the exposure time and the red blood cells damage depends only on the dissipation of the turbulent energy in the erythrocyte membrane. The analysis reported here opens the possibility of mapping the flow field in artificial assist devices based on the smallest eddy length scales. This is a promising new trend and should be considered in the designing requirements of the next generations of artificial organs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT Microsprinkler non-pressure compensating nozzles usually show water flow variation along the lateral line. This study aimed at adapting microtubes into non-compensating system of microsprinklers previous installed in the field, as a self-compensated nozzle, to improve the flow uniformity along the lateral line. Microtubes were adapted to three types of commercial microsprinklers. Tests were conducted, both in the laboratory and in field, to evaluate the microsprinkler performance at four different flows (40, 50, 60 and 70 L h-1) under pressure head range from 75 to 245 kPa. Nozzles presented coefficient of flow-rate variation (CVq) lower than 5.5% and distribution uniformity (DU) greater than 95%, which are classified as excellent. The original spatial water distribution of the microsprinkler did not change by using microtube as a nozzle. This device adapted to non-pressure compensating microsprinklers are functional and operate effectively with flows ranging up to 70 L h-1. Small variations at microsprinkler flows along the lateral line can occur, however, at random manner, which is common for pressure-compensating nozzles. Therefore, the microtube technique is able to control pressure variation in microsprinklers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract This article provides a comprehensive picture of IR in South America by applying content analysis to 7,857 articles published in 35 journals from six South American countries from 2006 to 2014 in order to discover what the predominant theories, methods and research areas in this field are, how scholars tend to combine them in their research designs, and what the profiles of regional journals are, regarding their epistemological, methodological and subject preferences. The findings reveal a predominantly Positivist and largely Qualitative discipline, resembling North American and European IR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a great demand for simpler and less costly laboratory techniques and for more accessible procedures for orchid breeders who do not have the necessary theoretical basis to use the traditional seed and clone production methods of orchids in vitro. The aim of this study was to assess the use of sodium hypochlorite (NaClO) as a decontaminant in the process of inoculating adult orchid explants of Arundina bambusifolia and Epidendrum ibaguenses. Solutions of NaClO (1.200, 2.400, 3.600, 4.800 and 6.000 mg L-1 - equivalent to 50, 100, 150, 200 and 250 mL L-1 of commercial bleach - CB) were sprayed on the explants (1.0 mL) and the culture medium (GB5), in the presence or absence of activated charcoal (2 g L-1). The explants used were nodal segments of field-grown adult plants. The procedures for inoculating the explants were conducted outside the laminar flow chamber (LFC), except for the control treatment (autoclaved medium and explant inoculation inside the LFC). The best results for fresh weight yield, height and number of shoots were obtained using NaClO in solution at 1.200 mg L-1 (equivalent to 50 mL L-1 commercial bleach) with activated charcoal in the culture medium. Fresh weight figures were 1.10 g/jar for Arundina bambusifolia and 0.16 g/jar for Epidendrum ibaguenses. Spraying the NaClO solutions controls the contamination of the culture medium already inoculated with the explants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydraulic conductivity is determined in laboratory assays to estimate the flow of water in saturated soils. However, the results of this analysis, when using distilled or deionized water, may not correspond to field conditions in soils with high concentrations of soluble salts. This study therefore set out to determine the hydraulic conductivity in laboratory conditions using solutions of different electrical conductivities in six soils representative of the State of Pernambuco, with the exchangeable sodium percentage adjusted in the range of 5-30%. The results showed an increase in hydraulic conductivity with both decreasing exchangeable sodium percentage and increasing electrical conductivity in the solution. The response to the treatments was more pronounced in soils with higher proportion of more active clays. Determination of hydraulic conductivity in laboratory is routinely performed with deionized or distilled water. However, in salt affected soils, these determinations should be carried out using solutions of electrical conductivity different from 0 dS m-1, with values close to those determined in the saturation extracts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To describe the migration flows of demand for public and private hospital care among the health regions of the state of Sao Paulo, Brazil. METHODS Study based on a database of hospitalizations in the public and private systems of the state of Sao Paulo, Southeastern Brazil, in 2006. We analyzed data from 17 health regions of the state, considering people hospitalized in their own health region and those who migrated outwards (emigration) or came from other regions (immigration). The index of migration effectiveness of patients from both systems was estimated. The coverage (hospitalization coefficient) was analyzed in relation to the number of inpatient beds per population and the indexes of migration effectiveness. RESULTS The index of migration effectiveness applied to the hospital care demand flow allowed characterizing health regions with flow balance, with high emigration of public and private patients, and with high attraction of public and private patients. CONCLUSIONS There are differences in hospital care access and opportunities among health regions in the state of Sao Paulo, Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic performance indexes of sensitivity, specificity, positive predictive value and efficiency were determined for dot-ELISA and IgG-ELISA tests in 340 leishmaniasis sera. Sensitivity of the dot-ELISA was significantly lower than IgG-ELISA's; the two tests had indexes of specificity and positive predictive value of the same magnitude. Seventy-eight sera gave a negative dot-ELISA test result and a positive IgG-ELISA test result. When sera were classified according to different criteria as how to interpret this diversity, the kappa statistic did not corroborate the classification indicating that the two tests display a substantial strength of agreement. The results presented indicate that performance indexes accrued in a survey where variables arc well known may be extrapolated to other population studies if the disease presents itself as highly prevalent (due to a selection bias or not) and may be expected to discriminate a disease status among test positives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The currently used pre-exposure anti-rabies immunization schedule in Brazil is the one called 3+1, employing suckling mouse brain vaccine (3 doses on alternate days and the last one on day 30). Although satisfactory results were obtained in well controlled experimental groups using this immunization schedule, in our routine practice, VNA levels lower than 0.5 IU/ml are frequently found. We studied the pre-exposure 3+1 schedule under field conditions in different cities on the State of São Paulo, Brazil, under variable and sometimes adverse circumstances, such as the use of different batches of vaccine with different titers, delivered, stored and administered under local conditions. Fifty out of 256 serum samples (19.5%) showed VNA titers lower than 0.5 IU/ml, but they were not distributed homogeneously among the localities studied. While in some cities the results were completely satisfactory, in others almost 40% did not attain the minimum VNA titer required. The results presented here, considered separately, question our currently used procedures for human pre-exposure anti-rabies immunization. The reasons determining this situation are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .