16 resultados para emitting phosphors

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hoover Pugedo light traps were modified for use with green and blue-light-emitting diodes to trap phlebotomine sandflies in northeastern Brazil. A total of 2,267 specimens belonging to eight genera and 15 species were sampled. The predominant species were Nyssomyia whitmani(34.41%) and Micropygomyia echinatopharynx(17.25%).The green LED trap prevailed over the blue and control lights; however, no statistically significant difference could be detected among the three light sources. Even without statistical significance, we suggest using LEDs as an attractant for the capture of sandflies because of several advantages over the conventional method with incandescent lamps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light emitting diode (LED) has been used in commercial poultry industry by presenting superior energy savings and providing feasibility on production process. The objective of this research was to evaluate performance and carcass yield of broiler chickens exposed to different LED colors compared with fluorescent lamps. For that, two experiments (E1 and E2) were performed and 2,646 Cobb® chickens were used. In experiment E1, male birds were exposed to 20 lux artificial lighting with red, yellow, blue, and white LED bulbs; and fluorescent bulb. In experiment E2, male and female birds were exposed to 15 lux artificial lighting with red and blue LED bulbs; and fluorescent bulb. Cumulative weight gain (kg), feed intake (kg), feed conversion, hot carcass weight (kg), carcass yield (%), and breast and thigh + drumstick yield (%) were used as response variables. Results showed no difference (p > 0.05) among treatments for performance, carcass yield, and cut yield in experiment E1. In experiment E2 there was only difference between genders (p < 0.05) and males showed higher total weight gain, feed intake, hot carcass weight and thigh + drumstick yield. Different LED color use had same effect as fluorescent lights on broiler performance and carcass yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Local head losses must be considered in estimating properly the maximum length of drip irrigation laterals. The aim of this work was to develop a model based on dimensional analysis for calculating head loss along laterals accounting for in-line drippers. Several measurements were performed with 12 models of emitters to obtain the experimental data required for developing and assessing the model. Based on the Camargo & Sentelhas coefficient, the model presented an excellent result in terms of precision and accuracy on estimating head loss. The deviation between estimated and observed values of head loss increased according to the head loss and the maximum deviation reached 0.17 m. The maximum relative error was 33.75% and only 15% of the data set presented relative errors higher than 20%. Neglecting local head losses incurred a higher than estimated maximum lateral length of 19.48% for pressure-compensating drippers and 16.48% for non pressure-compensating drippers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The biostimulating effect of laser radiation has been observed in many areas of Medicine. However, there are still several questions to be answered, among them the importance of light coherence in the stimulatory process. In the present study, we used light-emitting diodes (LED) to promote the stimulation of liver regeneration after partial hepatectomy in rats. Fourteen male Wistar rats weighing 200-250 g were submitted to partial hepatectomy (70%) followed by LED light irradiation (630 nm) of the remaining part of the liver at two doses, i.e., 10 (N = 7) and 140 (N = 7) J/cm². A group irradiated with laser, 590 nm (N = 7, 15 J/cm²) was performed for the study of proliferating cell nuclear antigen-labeling index. Data are reported as mean ± SEM. Statistical comparisons of the groups were performed by analysis of variance for parametric measurements followed by the Bonferroni post-test, with the level of significance set at P < 0.05. Respiratory mitochondrial activity was increased in the irradiated groups (states 3 and 4; P < 0.05), with better results for the group exposed to the lower LED dose (10 J/cm²). The proliferating cell nuclear antigen-labeling index, by immunohistochemical staining, was similar for both LED-exposed groups (P > 0.05) and higher than for the control group (P < 0.05). The cell proliferation index obtained with LED and laser were similar (P > 0.05). In conclusion, the present results suggest that LED irradiation promotes biological stimulatory effects during the early stage of liver regeneration and that LED is as effective as laser light, independent of the coherence, divergence and cromaticity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction and evaluation of an inexpensive flow photometer for clinical analysis, using a bicolour LED and a phototransistor adapted for tubular flow cell, are described. The instrument presents some new features such as: automatic zero, electronic calibration and peak-hold signal. When compared with a classical photometer, it is simpler and has the advantages of a flow analysis system: lower volumes of reagents and samples, lower levels of contamination, shorter time for analysis and lower analysis costs. The instrument was used in the determination of the constituents in blood samples. The results obtained agree with those obtained by a classical photometer and the precision was better.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sensitive and simple system was proposed for the in situ measurement of total aldehyde in outdoor or indoor ambient. The method is based on the use of a reagent drop as an useful interface to preconcentrate the sample prior to determination of total aldehyde as formaldehyde. The drop is formed at the tip of a cylindrical tube that contains two optical fibers placed on opposite sides and in contact with the reagent solution. One optical fiber carries the red light to the drop form a light emitting diode (LED). The transmitted light is measured by a second optical fiber/photodiode system. The analytical signal is read and converted into absorbance. The reagent solution of 3-methyl-2-benzothiazoline hydrazone (MBTH) forms a blue cation during reaction with formaldehyde that can be measured at 660 nm. Some aspects of kinetics reaction formation of dye were reevaluated. The formaldehyde reacts with MBTH and forms the azine in about 12 min. The oxidation of MBTH by Fe (III) and the formation of dye requires 3 min. The absorbance of the reagent drop is proportional to the sampling time and to the analyte concentration. The absorbance signal increases with increased sample gas flow until a maximum is reached then decreases until it forms a plateau. The proposed method was evaluated using both outdoor and indoor samples, and it was shown to viable provide an accurate measure of total aldehyde.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The history of the rare earths is rich in innovation and these elements have been the object of study of a number of scientists. Rare earths are used practically in almost all aspects of life and these applications are due to their outstanding properties, mainly spectroscopic and magnetic. In industry, the applications of rare earths are many, such as in catalysis, phosphors, magnetism, glass and lasers. In biological systems, rare earths are used, for example, as luminescent probes in the investigation of binding sites in proteins, labels in immunoassays and in noninvasive tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Complexes of Eu3+, Tb3+ and Gd3+ with dipicolinic acid, chelidamic acid and chelidonic acid have been synthesized in order to study the effect of the substituent groups on the luminescence of the lanthanide complexes. The luminescence of the Eu3+ and Tb3+ complexes was quantified by quantum yield measurements. The complexes of Gd3+ have been used to determine the energies of the triplet states of the ligands. The Tb3+ complex synthesized with dipicolinic acid presented the highest quantum yield due to the energy difference between the triplet state of the dipicolinic acid and the emitting level of the Tb3+ ion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A microcontrolled, portable and inexpensive photometer is described. It uses six light-emitting diodes (LEDs) as radiation sources and a phototransistor as detector, as well as a microcontroller (PIC - Programmable Controller of Interruption). This device provided total autonomy to the proposed photometer, which was successfully applied to determination of Fe2+ in ferrous syrups and of seven clinical biochemical parameters. As the components are cheap (~U$30.00) and easy to find, the proposed photometer is an economical alternative for routine chemical analyses in small laboratories, for research and teaching. Being portable and microcontrolled, it allows doing field chemical analyses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Here we present an overview of electroluminescent devices that use conjugated polymers as the active media. The principal components of the devices are described and we show some examples of conjugated polymers and copolymers usually employed in polymeric light emitting devices (PLED). Some aspects of the photo and electroluminescence properties as well as of the energy transfer processes are discussed. As an example, we present some of the photophysical properties of poly(fluorene)s, a class of conjugated polymers with blue emission.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study aims at assessing the influence of pollution from mobile sources on air quality in the Metropolitan Area of Porto Alegre by means of an inventory based on methods applied specifically to vehicular emissions. The study uses the method described by CETESB, based on inventories on vehicular emissions, according to USEPA methodology. Following fuel types were taken into account: gasoline (24% ethanol), alcohol, diesel oil, and CNG (compressed natural gas). Results have shown that gasoline-powered vehicles are still responsible for emitting the highest CO and HC concentrations, while diesel-powered vehicles are the source of highest NOx, MP and SOx concentrations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Colloidal semiconductor nanocrystals, also known as quantum dots, have attracted great attention since they have interesting size-dependent properties due to the quantum confinement effect. These nanoparticles are highly luminescent and have potential applications in different technological areas, including biological labeling, light-emitting diodes and photovoltaic devices. The synthetic methods of semiconductor nanocrystals have progressed in the last 30 years, and several protocols were developed to synthesize monodisperse nanocrystals with good optical properties, different compositions and morphologies. This review describes the main methods used to synthesize nanocrystals in the II-VI and III-V systems, and the recent approaches in this field of research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work is presented a versatile system for X-ray excited optical luminescence (XEOL) measurements. The apparatus was assembled from a sample holder connected to an optical fiber responsibly for the acquisition of the scintillation signal. The spectrum is registered with a CCD coupled in a spectrograph provided with diffraction gratings. The system performance was analyzed by exciting GdAlO3:Eu3+ 3.0 at.% with X-rays from a diffractometer and measuring the emission spectra. The system can be used to obtain precise and reliable spectroscopic properties of samples with various conformations without the loss of the required safety when dealing with ionizing radiations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study reports on the construction of a turbidimeter employing light emitting diodes as radiation source at a wavelength of 405 nm, a photodiode as detector, a temperature sensor and a microcontroller used for data acquisition and processing. The turbidimeter was applied to determine sulfate concentrations in natural water employing barium chloride as reagent. Potential interferences and recovery studies were performed and an interference of 3.5 % and a recovery between 97.8 and 108 % were estimated. The analytical performance of in situ turbidimeter for the determination of sulfate was evaluated and compared with two commercial spectrophotometers and a good agreement was obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Shadow masks are used in manufacturing processes for electro-optic devices to transfer patterns with different shapes and dimensions. For fabrication of organic based devices, shadow masks should be made of materials stable against organic solvents, high temperature, and robust, remaining unchanged after multiple cycles of use and fixation. Thus, stainless steel is suitable for shadow masks. A simple, cheap and quick method of obtaining shadow masks by electrochemical corrosion of stainless steel is reported. The shadow mask was used to evaporate cathode material to obtain an organic light emitting diode with active area of 9 mm². This device exhibited a turn-on voltage of 5 V and luminance of 14 cd/m².