12 resultados para direct measurements
em Scielo Saúde Pública - SP
Resumo:
INTRODUCTION: Self-reported weight and height were compared with direct measurements in order to evaluate the agreement between the two sources. METHOD: Data were obtained from a cross-sectional study on health status from a probabilistic sample of 1,183 employees of a bank, in Rio de Janeiro State, Brazil. Direct measurements were made of 322 employees. Differences between the two sources were evaluated using mean differences, limits of agreement and intraclass correlation coefficient (ICC). RESULTS AND CONCLUSIONS: Men and women tended to underestimate their weight while differences between self-reported and measured height were insignificant. Body mass index (BMI) mean differences were smaller than those observed for weight. ICC was over 0.98 for weight and 0.95 for BMI, expressing close agreement. Combining a graphical method with ICC may be useful in pilot studies to detect populational groups capable of providing reliable information on weight and height, thus minimizing resources needed for field work.
Resumo:
Infinity readings for first order kinetics can be calculated from any three measurements (triads) of a physical property l at three equallyspaced times. Accurate results can be obtained from time intervals aslow as 0.4 half-life. Calculation of infinity readings l¥ from severaltriads at increasing values of time gives an insight into the deviation of the first order kinetics when parallel, consecutive or other spurious reactions occur along with the main first order reaction, not allowing direct measurements or calculation of l¥. The proposed method is more sensitive in distinguishing between first and second order kinetics than the Guggenheim and Kezdy-Swinbourne methods.
Resumo:
Spectrophotometry is one of the most widespread analytical techniques due to its simplicity, reliability, and low-cost instrumentation for both direct measurements and coupled to other techniques or processes such as chromatography, electrophoresis and flow analysis. However, the application is often limited by sensitivity. This article describes some advances that greatly improve the performance of spectrophotometric measurements, especially in order to increase sensitivity, including the employment of liquid-core waveguides and solid-phase spectrophotometry.
Resumo:
Direct measurements of Redox Potential (ORP) have been used to infer the degree of electrons availability in waters, wastewaters, sediments and soils. Although the interpretation of the results obtained in direct measurements is not trivial, this parameter is part of a list of compulsory determinations required by many Environmental State Agencies as well as consulting companies. Nonetheless, the vast majority of E H reported values are not corrected to the reference electrode used, what makes most of the data incomparable with the literature, and not suitable for a correct environmental diagnostics.
Resumo:
In this paper, two simple ways of evaluating carbon steel sheet corrosion in a hydrochloric acid solution were presented as an experimental proposal for corrosion teaching. The first method is based on direct measurements of mass before and after corrosion tests. The second approach follows the principle of visual colorimetry by which soluble corrosion products are transformed into red complexes allowing monitoring of the products’ concentration according to increases in solution color intensity. Both methods proved able to determine the corrosion rate.
Resumo:
The present study was designed to compare the homeostasis model assessment (HOMA) and quantitative insulin sensitivity check index (QUICKI) with data from forearm metabolic studies of healthy individuals and of subjects in various pathological states. Fifty-five healthy individuals and 112 patients in various pathological states, including type 2 diabetes mellitus, essential hypertension and others, were studied after an overnight fast and for 3 h after ingestion of 75 g of glucose, by HOMA, QUICKI and the forearm technique to estimate muscle uptake of glucose combined with indirect calorimetry (oxidative and non-oxidative glucose metabolism). The patients showed increased HOMA (1.88 ± 0.14 vs 1.13 ± 0.10 pmol/l x mmol/l) and insulin/glucose (I/G) index (1.058.9 ± 340.9 vs 518.6 ± 70.7 pmol/l x (mg/100 ml forearm)-1), and decreased QUICKI (0.36 ± 0.004 vs 0.39 ± 0.006 (µU/ml + mg/dl)-1) compared with the healthy individuals. Analysis of the data for the group as a whole (patients and healthy individuals) showed that the estimate of insulin resistance by HOMA was correlated with data obtained in the forearm metabolic studies (glucose uptake: r = -0.16, P = 0.04; non-oxidative glucose metabolism: r = -0.20. P = 0.01, and I/G index: r = 0.17, P = 0.03). The comparison of QUICKI with data of the forearm metabolic studies showed significant correlation between QUICKI and non-oxidative glucose metabolism (r = 0.17, P = 0.03) or I/G index (r = -0.37, P < 0.0001). The HOMA and QUICKI are good estimates of insulin sensitivity as data derived from forearm metabolic studies involving direct measurements of insulin action on muscle glucose metabolism.
Resumo:
The severity of left ventricular (LV) dysfunction in rats with myocardial infarction (MI) varies widely. Because homogeneity in baseline parameters is essential for experimental investigations, a study was conducted to establish whether Doppler echocardiography (DE) could accurately identify animals with high LV end-diastolic pressure as a marker of LV dysfunction soon after MI. Direct measurements of LV end-diastolic pressure were made and DE was performed simultaneously 1 week after surgically induced MI (N = 16) or sham-operation (N = 17) in female Wistar rats (200 to 250 g). The ratio of peak early (E) to late (A) diastolic LV filling velocities and the ratio of E velocity to peak early (Em) diastolic myocardial velocity were the best predictors of high LV end-diastolic pressure (>12 mmHg) soon after MI. Cut-off values of 1.77 for the E/A ratio (P = 0.001) identified rats with elevated LV end-diastolic pressure with 90% sensitivity and 80% specificity. Cut-off values of 20.4 for the E/Em ratio (P = 0.0001) identified rats with elevated LV end-diastolic pressure with 81.8% sensitivity and 80% specificity. Moreover, E/A and E/Em ratios were the only echocardiographic parameters independently associated with LV end-diastolic pressure in multiple linear regression analysis. Therefore, DE identifies rats with high LV end-diastolic pressure soon after MI. These findings have implications for using serial DE in animal selection and in the assessment of their response to experimental therapies.
Resumo:
The pancreatic acinar cell is a classical model for studies of secretion and signal transduction mechanisms. Because of the extensive endoplasmic reticulum and the large granular compartment, it has been possible - by direct measurements - to obtain considerable insights into intracellular Ca2+ handling under both normal and pathological conditions. Recent studies have also revealed important characteristics of stimulus-secretion coupling mechanisms in isolated human pancreatic acinar cells. The acinar cells are potentially dangerous because of the high intra-granular concentration of proteases, which become inappropriately activated in the human disease acute pancreatitis. This disease is due to toxic Ca2+ signals generated by excessive liberation of Ca2+ from both the endoplasmic reticulum and the secretory granules.
Resumo:
This study investigated the reductive degradation of acetamiprid (5 mg L-1) in aqueous medium (at pH 2.0) induced by zero-valent iron (50 mg). The process was monitored using high-performance liquid chromatography (HPLC) to determine the degradation rate as a function of reaction time, and direct infusion electrospray ionization mass spectrometry (DI-ESI-MS) to search for (and potentially characterize) any possible byproducts formed during degradation. The results obtained via HPLC showed that after 60 min, the degradation of the substrate reached nearly 100% in an acidic medium, whereas the mineralization rate (as determined by total organic carbon measurements) was as low as 3%. Data obtained by DI-ESI-MS showed that byproducts were formed mainly by insertions of hydrogen atoms into the nitrile, imine, and pyridine ring moieties, in addition to the observation of chlorine substitution by hydrogen replacement (hydrodechlorination) reactions.
Resumo:
A flow-injection system with sample and reagent addition by the synchronous merging zones approach for calcium determination in milk by flame AAS is proposed. Main parameters were optimized using a factorial design with central point. The optimum conditions were 2.5% (m/v) for La concentration, 8 mL min-1 for the carrier flow-rate, 20 cm for coiled reactor and 250 ìL for sample volume. Different sample preparation procedures were evaluated such as dilution in water or acid and microwave-assisted decomposition using concentrated or diluted acids. The optimized flow system was applied to determine Ca in eleven commercial milk samples and two standard reference materials diluted in water. Similar calcium levels were encountered comparing the results obtained by the proposed method (dilution in water) with those obtained using microwave-oven digestion. Results obtained in two standard reference materials were in agreement at 95% confidence level with those certified. Recoveries of spiked samples were in the 93% - 116% range. Relative standard deviation (n = 12) was < 5.4% and the sample throughput was 150 measurements per hour, corresponding to a consumption of 250 µL of sample and 6.25 mg La per determination.
Resumo:
In general, the traditional Physics courses needs examples of the aplications of the Physics concepts in other areas such as Chemistry and Biology. This lacks tend to demotivate Chemistry and Biology students regarding to deal with Physical concepts developed in classroom. In this work, the analogy among mechanic and electric oscillators is investigated to be applied in Chemistry and Biology areas, showing to be valuable due to its aplication in techniques that aims to measure mass variation with high precision. This measure could be made in a direct or indirect way. These techniques are known as electrogravimetric techniques and they are important in biosensor aplications. Thus, this paper explores the electromechanic analogy in an interdisciplinary way involving areas like Physics, Chemistry and Biology. Based on this analogy, it is proposed an experiment that can be applied in different ways, i.e. by an basic approach or more deeper, depending on the students specific formation, in other words, Physics, Chemistry or Biology.
Resumo:
This paper presents a new approach in tomographic instrumentation for agriculture based on Compton scattering, which allows for the simultaneous measurements of density and moisture of soil samples. Compton tomography is a technique that can be used to obtain a spatial map of electronic density of samples. Quantitative results can be obtained by using a reconstruction algorithm that takes into account the absorption of incident and scattered radiation. Results show a coefficient of linear correlation better than 0.81, when comparison is made between soil density measurements based on this method and direct transmission tomography. For soil water contents, a coefficient of linear correlation better than 0.79 was found when compared with measurements obtained by time domain reflectrometry (TDR). In addition, a set of Compton scatter images are presented to illustrate the efficacy of this imaging technique, which makes possible improved spatial variability analysis of pre-established planes.