21 resultados para digital signal processor
em Scielo Saúde Pública - SP
Resumo:
Cyclic voltammetry has become one of the most useful tools in modern electrochemistry, but the use of digital potentiostats should be treated with caution by users. Staircase Voltammetry utilizes some parameters to build up the potential ramp. However, for some electrochemical processes, the signal response can be different compared with that acquired using true linear sweep (analogic signal). In this work, the role of SCV parameters in current response during the hydrogen electrochemical adsorption/desorption reaction on a platinum surface was studied. In addition, the transient current in each step comprising the ramp was investigated. The results showed that with a step height of 2 mV, the SCV response matches that recorded by linear sweep voltammetry. From the transient current study, two kinds of capacity were identified: non-faradaic and faradaic charge.
Resumo:
OBJECTIVE: To assess signal-averaged electrocardiogram (SAECG) for diagnosing incipient left ventricular hypertrophy (LVH). METHODS: A study with 115 individuals was carried out. The individuals were divided as follows: GI - 38 healthy individuals; GII - 47 individuals with mild to moderate hypertension and normal findings on echocardiogram and ECG; and GIII - 30 individuals with hypertension and documented LVH. The magnitude vector of the SAECG was analyzed with the high-pass cutoff frequency of 40 Hz through the bidirectional four-pole Butterworth high-pass digital filter. The mean quadratic root of the total QRS voltage (RMST) and the two-dimensional integral of the QRS area of the spectro-temporal map were analyzed between 0 and 30 Hz for the frequency domain (Int FD), and between 40 and 250 Hz for the time domain (Int TD). The electrocardiographic criterion for LVH was based on the Cornell Product. Left ventricular mass was calculated with the Devereux formula. RESULTS: All parameters analyzed increased from GI to GIII, except for Int FD (GII vs GIII) and RMST log (GII vs GIII). Int TD showed greater accuracy for detecting LVH with an appropriate cutoff > 8 (sensitivity of 55%, specificity of 81%). Positive values (> 8) were found in 56.5% of the G II patients and in 18.4% of the GI patients (p< 0.0005). CONCLUSION: SAECG can be used in the early diagnosis of LVH in hypertensive patients with normal ECG and echocardiogram.
Resumo:
Ventricular late potentials are low-amplitude signals originating from damaged myocardium and detected on the body surface by ECG filtering and averaging. Digital filters present in commercial equipment may interfere with the ability of arrhythmia stratification. We compared 40-Hz BiSpec (BI) and classical 40- to 250-Hz band-pass Butterworth bidirectional (BD) filters in terms of impact on time domain variables and diagnostic properties. In a transverse retrospective age-adjusted case-control study, 221 subjects with sinus rhythm without bundle branch block were divided into three groups after signal-averaged ECG acquisition: GI (N = 40), clinically normal controls, GII (N = 158), subjects with coronary heart disease without sustained monomorphic ventricular tachycardia (SMVT), and GIII (N = 23), subjects with heart disease and documented SMVT. Conventional variables analyzed from vector magnitude data after averaging to 0.3 µV final noise were obtained by application of each filter to the averaged signal, and evaluated in pairs by numerical comparison and by diagnostic agreement assessment, using conventional and optimized thresholds of normality. Significant differences were found between BI and BD variables in all groups, with diagnostic results showing significant disagreement between both filters [kappa value of 0.61 (P<0.05) for GII and 0.31 for GIII (P = NS)]. Sensitivity for SMVT was lower with BI than with BD (65.2 vs 91.3%, respectively, P<0.05). Filters provided significantly different numerical and diagnostic results and the BI filter showed only limited clinical application to risk stratification of ventricular arrhythmia.
Resumo:
OBJETIVO: objetivo desta pesquisa foi investigar o grau de satisfação entre os usuários de Aparelho de Amplificação Sonora (AAS) de tecnologia analógica e digital. FORMA DE ESTUDO: clínico com coorte transversal. MATERIAL E MÉTODO: A amostra foi constituída de 40 usuários de AAS unilateral, sendo 20 de tecnologia analógica (Grupo I) e 20 de tecnologia digital (Grupo II). Os indivíduos são portadores de perda auditiva neurossensorial, de configuração plana, de grau leve a moderado, com idade entre 40 e 95 anos. O instrumento de avaliação utilizado foi o International Outcome Inventory for Hearing Aids (IOI-HA - Versão em Português) proposto por Cox et al. (2002). RESULTADOS: Os resultados mostraram que os usuários do Grupo II utilizam o AAS por mais tempo diariamente e também apresentam um grau de dificuldade menor em determinadas situações com o uso da amplificação, comparado aos usuários do Grupo I. Os usuários do Grupo II relatam que sua perda auditiva não afeta em nada sua relação com terceiros. CONCLUSÃO: Apesar de os resultados revelarem que os usuários do Grupo I apresentam um handicap auditivo mais acentuado comparado aos usuários do Grupo II, o grau de satisfação com relação à amplificação não apresenta diferença significativa entre os dois grupos.
Resumo:
Este artigo investiga as representações sociais que emergem da participação pública mediada pelo uso de Tecnologias de Informação e Comunicação (TIC). A prefeitura de Belo Horizonte, em 2006, usou pela primeira vez a TIC no Orçamento Participativo Digital (OP Digital). Foi uma escolha da população das obras prioritárias para o biênio seguinte. O OP Digital foi repetido em 2008 e 2011, mas com participação inferior à obtida na primeira edição. Realizamos este trabalho para compreender o uso da internet pelo cidadão na tomada de decisão pública e para explicar a diminuição da sua participação. Os procedimentos metodológicos estão ancorados na teoria das representações sociais e na análise crítica do discurso de 101 textos - da imprensa e de órgãos públicos ou representantes do governo. Os resultados nos indicam que não está sendo explorado o potencial de interação e construção coletiva da internet, ancorando a nova prática em uma votação, dessa forma, trivializando-a. Essa pode ser uma das razões para o abandono da participação.
Resumo:
Este trabalho analisa três edições (2006, 2008 e 2011) do Orçamento Participativo Digital (OPD) de Belo Horizonte (MG). Objetiva deslindar os sentidos e significados da participação democrática mediada pela internet nessa experiência. Utiliza-se como método o estudo de caso único, de natureza qualitativa. Os dados foram coletados por meio de observação direta nos sítios do OPD e análise documental. Durante a fase de observação direta foram coletadas mensagens e manifestações dos cidadãos que estavam participando do processo. Tais dados foram tratados com o software Atlas TI 6.0®. Conclui-se que tanto o sentido quanto o significado democrático dessa experiência de participação mediadas pela internet são modificados ao longo das edições, indo de grandes impulsos de esperança democrática até a descrença nessa modalidade de participação digital.
Resumo:
ABSTRACT This study aimed to describe the digital disease detection and participatory surveillance in different countries. The systems or platforms consolidated in the scientific field were analyzed by describing the strategy, type of data source, main objectives, and manner of interaction with users. Eleven systems or platforms, developed from 1996 to 2016, were analyzed. There was a higher frequency of data mining on the web and active crowdsourcing as well as a trend in the use of mobile applications. It is important to provoke debate in the academia and health services for the evolution of methods and insights into participatory surveillance in the digital age.
Resumo:
OBJETVO: Detectar a freqüência da prescrição do digital, assim como as suas indicações, em idosos admitidos em unidade de geriatria de um hospital geral. MÉTODOS: Foram investigados, consecutivamente, 130 pacientes não selecionados, de ambos os sexos (100 mulheres e 30 homens), com idades > ou = 65 (média 80±9) anos. Os pacientes foram avaliados através de exame clínico completo, rotina básica de sangue, radiografia simples de tórax, eletrocardiograma e ecocardiograma Doppler. Baseados na avaliação clínica e exames complementares, o uso do digital foi considerado adequado, questionável ou inadequado. RESULTADOS: Estavam em uso de digital 27,6% dos pacientes. A indicação foi considerada adequada em 36,1%, questionável em 11,1% e inadequada em 52,7%. CONCLUSÃO: Uma alta prevalência de prescrição do digital foi detectada nos idosos admitidos, sendo que a maior parte a adotava por razões consideradas inadequadas ou questionáveis. Devido ao risco aumentado de intoxicação digitálica nessa faixa etária, a droga deveria ser prescrita sob indicações mais criteriosas.
Resumo:
OBJECTIVE: Using P-wave signal-averaged electrocardiography, we assessed the patterns of atrial electrical activation in patients with idiopathic atrial fibrillation as compared with patterns in patients with atrial fibrillation associated with structural heart disease. METHODS: Eighty patients with recurrent paroxysmal atrial fibrillation were divided into 3 groups as follows: group I - 40 patients with atrial fibrillation associated with non-rheumatic heart disease; group II - 25 patients with rheumatic atrial fibrillation; and group III - 15 patients with idiopathic atrial fibrillation. All patients underwent P-wave signal-averaged electrocardiography for frequency-domain analysis using spectrotemporal mapping and statistical techniques for detecting and quantifying intraatrial conduction disturbances. RESULTS: We observed an important fragmentation in atrial electrical conduction in 27% of the patients in group I, 64% of the patients in group II, and 67% of the patients in group III (p=0.003). CONCLUSION: Idiopathic atrial fibrillation has important intraatrial conduction disturbances. These alterations are similar to those observed in individuals with rheumatic atrial fibrillation, suggesting the existence of some degree of structural involvement of the atrial myocardium that cannot be detected with conventional electrocardiography and echocardiography.
Resumo:
FUNDAMENTO: Medidas válidas da pressão arterial, em situações clínicas e na comunidade, são essenciais para a monitoração dessa variável em nível populacional. OBJETIVO: Avaliar a validade de um monitor digital de pulso para mensuração da pressão arterial em adolescentes, em comparação com um esfigmomanômetro de mercúrio. MÉTODOS: Um estudo de validação foi realizado na cidade de Pelotas, região sul do Brasil. A pressão arterial foi medida duas vezes, utilizando-se dois esfigmomanômetros diferentes: um aparelho digital de pulso OMRON e um aparelho de mesa BD de mercúrio. Metade da amostra foi medida primeiro através do manômetro digital e depois pelo de mercúrio, enquanto a outra metade foi avaliada na ordem inversa. A concordância entre as duas medidas foi avaliada através do método de Bland & Altman. RESULTADOS: 120 adolescentes com idade entre 14 e 15 anos foram incluídos no estudo (50% de cada sexo). A pressão sistólica média entre os meninos foi de 113,7 mmHg (DP 14,2) usando o manômetro de mercúrio e 115,5 mmHg (DP 15,2) usando o aparelho digital. Os valores equivalentes para a pressão diastólica foram 61,5 mmHg (DP 9,9) e 69,6 mmHg (10,2), respectivamente. Entre as meninas, a pressão sistólica média foi de 104,7 mmHg (DP 10,1) usando o manômetro de mercúrio e 102,4 mmHg (DP 11.9) usando o aparelho digital. Os valores equivalentes para a pressão diastólica foram 60,0 mmHg (DP 10,4) e 65,7 mmHg (DP 7,7), respectivamente. CONCLUSÕES: O manômetro digital apresentou alta concordância com o manômetro de mercúrio para medir a pressão arterial sistólica. A concordância foi menor para a pressão arterial diastólica. O uso de equações de correção pode ser uma alternativa para estudos utilizando esse monitor digital de pulso em adolescentes.
Resumo:
O exame físico cardiovascular, em particular a ausculta cardíaca, é uma das habilidades clínicas mais difíceis para os alunos durante seu treinamento médico. Estudos sugerem que o uso de tecnologias, como o estetoscópio digital, aumente a acurácia do exame clínico, entretanto, seu impacto no ensino da propedêutica da ausculta cardíaca em alunos de graduação de Medicina não é conhecido. O objetivo é demonstrar a utilidade do estetoscópio digital, em comparação com métodos tradicionais, como instrumento de ensino da ausculta cardíaca. Estudo de intervenção, longitudinal, controlado, unicêntrico e randomizado. Foram inscritos 38 alunos de medicina para um curso de semiologia cardiovascular com duração de oito semanas. Definiu-se um programa com aulas expositivas e à beira do leito nas enfermarias de Cardiologia. Nas aulas práticas, os alunos foram randomizados em dois grupos: 1) (n = 21) estetoscópio digital (Littmann® modelo 3200, 3M); e 2) (n = 17) estetoscópios convencionais. Foi realizada uma avaliação pré-treinamento, através de um teste utilizando o software Heart Sounds®, que foi repetida ao final do curso. As médias das avaliações foram comparadas pelo teste T pareado e não pareado. Observa-se que, ao final do curso, houve uma melhora significativamente maior no grupo que utilizou o estetoscópio digital (51,9%) quando comparado ao grupo que utilizou o estetoscópio convencional (29,5%). Intervenções de curta duração para o ensino de semiologia cardíaca são capazes de contribuir de modo significativo para melhora da proficiência da identificação dos sons cardíacos. O uso do estetoscópio digital demonstrou ser um fator positivo no ensino dessas habilidades.
Resumo:
Activation of the eosinophil NADPH oxidase and the subsequent release of toxic oxygen radicals has been implicated in the mechanism of parasite killing and inflammation. At present, little is known of the signal transduction pathway that govern agonist-induced activation of the respiratory burst and is the subject of this review. In particular, we focus on the ability of leukotrine B4 to activate the NADPH oxidase in guinea-pig peritoneal eosinophils which can be obtained in sufficient number and purity for detailed biochemical experiments to be performed.