343 resultados para curve detection

em Scielo Saúde Pública - SP


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay was standardized for the detection of cryptococcal antigen in serum and cerebrospinal fluid. The system was evaluated in clinical samples from patients infected by human immunodeficiency virus with and without previous cryptococcosis diagnosis. The evaluated system is highly sensitive and specific, and when it was compared with latex agglutination there were not significant differences. A standard curve with purified Cryptococcus neoformans antigen was settled down for the antigen quantification in positive samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A real-time polymerase chain reaction (PCR) assay with fluorescence resonance energy transfer (FRET) hybridisation probes combined with melting curve analysis was developed to detect Schistosoma japonicum in experimentally infected snails and in faecal samples of infected mice. This procedure is based on melting curve analysis of a hybrid between an amplicon from the S. japonicum internal transcribed spacer region 2 sequence, which is a 192-bp S. japonicum-specific sequence, and fluorophore-labelled specific probes. Real-time FRET PCR could detect as little as a single cercaria artificially introduced into a pool of 10 non-infected snails and a single egg inoculated in 100 mg of non-infected mouse faeces. All S. japonicum-infected snails and all faecal samples from infected mice were positive. Non-infected snails, non-infected mouse faeces and genomic DNA from other parasites were negative. This assay is rapid and has potential for epidemiological S. japonicum surveys in snails, intermediate hosts and faecal samples of final hosts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The reverse transcription-polymerase chain reaction (RT-PCR) is the most sensitive method used to evaluate gene expression. Although many advances have been made since quantitative RT-PCR was first described, few reports deal with the mathematical bases of this technique. The aim of the present study was to develop and standardize a competitive PCR method using standard-curves to quantify transcripts of the myogenic regulatory factors MyoD, Myf-5, Myogenin and MRF4 in chicken embryos. Competitor cDNA molecules were constructed for each gene under study using deletion primers, which were designed to maintain the anchorage sites for the primers used to amplify target cDNAs. Standard-curves were prepared by co-amplification of different amounts of target cDNA with a constant amount of competitor. The content of specific mRNAs in embryo cDNAs was determined after PCR with a known amount of competitor and comparison to standard-curves. Transcripts of the housekeeping ß-actin gene were measured to normalize the results. As predicted by the model, most of the standard-curves showed a slope close to 1, while intercepts varied depending on the relative efficiency of competitor amplification. The sensitivity of the RT-PCR method permitted the detection of as few as 60 MyoD/Myf-5 molecules per reaction but approximately 600 molecules of MRF4/Myogenin mRNAS were necessary to produce a measurable signal. A coefficient of variation of 6 to 19% was estimated for the different genes analyzed (6 to 9 repetitions). The competitive RT-PCR assay described here is sensitive, precise and allows quantification of up to 9 transcripts from a single cDNA sample.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a fast (less than 3 h) and cost-effective melting temperature assay method for the detection of single-nucleotide polymorphisms in the MBL2 gene. The protocol, which is based on the Corbett Rotor Gene real time PCR platform and SYBR Green I chemistry, yielded, in the cohorts studied, sensitive (100%) and specific (100%) PCR amplification without the use of costly fluorophore-labeled probes or post-PCR manipulation. At the end of the PCR, the dissociation protocol included a slow heating from 60º to 95ºC in 0.2ºC steps, with an 8-s interval between steps. Melting curve profiles were obtained using the dissociation software of the Rotor Gene-3000 apparatus. Samples were analyzed in duplicate and in different PCR runs to test the reproducibility of this technique. No supplementary data handling is required to determine the MBL2 genotype. MBL2 genotyping performed on a cohort of 164 HIV-1-positive Brazilian children and 150 healthy controls, matched for age and sex and ethnic origin, yielded reproducible results confirmed by direct sequencing of the amplicon performed in blind. The three MBL2 variants (Arg52Cys, Gly54Asp, Gly57Glu) were grouped together and called allele 0, while the combination of three wild-type alleles was called allele A. The frequency of the A/A homozygotes was significantly higher among healthy controls (0.68) than in HIV-infected children (0.55; P = 0.0234) and the frequency of MBL2 0/0 homozygotes was higher among HIV-1-infected children than healthy controls (P = 0.0296). The 0 allele was significantly more frequent among the 164 HIV-1-infected children (0.29) than among the 150 healthy controls (0.18; P = 0.0032). Our data confirm the association between the presence of the mutated MBL2 allele (allele 0) and HIV-1 infection in perinatally exposed children. Our results are in agreement with the literature data which indicate that the presence of the allele 0 confers a relative risk of 1.37 for HIV-1 infection through vertical transmission.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hereditary hemochromatosis (HH) is a common autosomal disorder of iron metabolism mainly affecting Caucasian populations. Three recurrent disease-associated mutations have been detected in the hemochromatosis gene (HFE): C282Y, H63D, and S65C. Although HH phenotype has been associated with all three mutations, C282Y is considered the most relevant mutation responsible for hemochromatosis. Clinical complications of HH include cirrhosis of the liver, congestive cardiac failure and cardiac arrhythmias, endocrine pancreatic disease, which can be prevented by early diagnosis and treatment. Therefore, a reliable genotyping method is required for presymptomatic diagnosis. We describe the simultaneous detection of the C282Y, H63D and S65C mutations in the hemochromatosis gene by real-time PCR followed by melting curve analysis using fluorescence resonance energy transfer (FRET) probes. The acceptor fluorophore may be replaced by a quencher, increasing multiplex possibilities. Real-time PCR results were compared to the results of sequencing and conventional PCR followed by restriction digestion and detection by agarose gel electrophoresis (PCR-RFLP). Genotypes from 80 individuals obtained both by the conventional PCR-RFLP method and quenched-FRET real-time PCR were in full agreement. Sequencing also confirmed the results obtained by the new method, which proved to be an accurate, rapid and cost-effective diagnostic assay. Our findings demonstrate the usefulness of real-time PCR for the simultaneous detection of mutations in the HFE gene, which allows a reduction of a significant amount of time in sample processing compared to the PCR-RFLP method, eliminates the use of toxic reagents, reduces the risk of contamination in the laboratory, and enables full process automation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method using Liquid Chromatography Tanden Mass Spectrometry (LC-MS/MS) with matrix-matched calibration curve was developed and validated for determining ochratoxin A (OTA) in green coffee. Linearity was found between 3.0 and 23.0 ng.g-1. Mean recoveries ranged between 90.45% and 108.81%; the relative standard deviation under repeatability and intermediate precision conditions ranged from 5.39% to 9.94% and from 2.20% to 14.34%, respectively. The limits of detection and quantification were 1.2 ng.g-1 and 3.0 ng.g-¹, respectively. The method developed was suitable and contributed to the field of mycotoxin analysis, and it will be used for future production of the Certified Reference Material (CRM) for OTA in coffee.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study were a) to assess the ability of primary care doctors to make accurate ratings of psychiatric disturbance and b) to evaluate the use of a case-finding questionnaire in the detection of psychiatric morbidity. The estudy took place in three primary care clinics in the city of São Paulo, Brazil, during a six-month survey. A time sample of consecutive adult attenders were asked to complete a case-finding questionnaire for psychiatric disorders (the Self Report Questionnaire - SRQ) and a subsample were selected for a semi-structured psychiatric interview (the Clinical Interview Schedule - CIS). At the end of the consultation the primary care doctors were asked to assess, in a standardized way, the presence or absence of psychiatric disorder; these assessments were then compared with that ratings obtained in the psychiatric interview. A considerable proportion of minor psychiatric morbidity remained undetected by the three primary care doctors: the hidden morbidity ranged from 22% to 79%. When these were compared to those of the case-finding questionnaire, they were consistently lower, indicating that the use of these instruments can enhance the recognition of psychiatric disorders in primary care settings. Four strategies for adopting the questionnaire are described, and some of the clinical consequences of its use are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of studies in the field of Epidemiological Psychiatry have been performed over the last two decades, and these have focused on the ability of primary care physicians to detect emotional disorders in the patients that attend their practices. The scientific methodology utilized in these studies is the subject of this review, which contains a discussion concerning: a) interviewer awareness bias; b) accuracy of the instruments and c) medical and psychological concepts involved in defining minor emotional disorders. Suggestions for change in the methodology are made in each of the sections of the review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryptosporidium sp., a coccidian parasite usually found in the faeces of cattle, has been recently implicated as an agent of human intestinal disease, mainly in immunocompromised patients. In the study realized, by an indirect immunofluorescence technique, specific immunoglobulins (IgG and IgM) have been demonstrated in human serum against Cryptosporidium oocysts. Purified oocysts were used as antigens in the indirect immunofluorecence assay. After analyzing this test in sera from selected groups of patients, the frequency of both specific IgG and IgM of immunocompetent children who were excreting oocysts in their faeces was 62% and in children with negative excretion of oocysts was 20% and 40%, respectively. In adults infected with the human immunodeficiency virus (HIV) and who were excreting Cryptosporidium in their stools, the frequency was 57% for IgG but only 2% for IgM. Twenty three percent of immunocompromised adults with not determined excretion of oocysts in their stools had anti-Cryptosporidium IgG in their sera. Children infected with human immunodeficiency virus had no IgM and only 14% had IgG detectable in their sera. The indirect immunoflorescence assay, when used with other parasitological techniques appears to be useful for retrospective population studies and for diagnosis of acute infection. The humoral immune response of HIV positive patients to this protozoan agent needs clarification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVES: To detect anti-Giardia lamblia serum antibodies in healthy children attending public day care centers and to assess serological tests as tools for estimating the prevalence of G. lamblia in endemic areas. METHODS: Three separate stool specimens and filter paper blood samples were collected from 147 children ranging from 0 to 6 years old. Each stool sample was processed using spontaneous sedimentation and zinc sulfate flotation methods. Blood samples were tested by indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assay (ELISA) for Giardia IgG. RESULTS AND CONCLUSIONS: Of 147 individuals tested, 93 (63.3%) showed Giardia cysts in their feces. Using IIF and ELISA, serum antibodies were detected in 93 (63.3%) and 100 (68%) samples , respectively. Sensitivity of IIF and ELISA was 82% and 72%, respectively. However, ELISA revealed to be less specific (39%) than IIF (70%). IIF also showed a higher concordance with microscopic examination than ELISA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To comparatively detect A. actinomycetemcomitans and F. nucleatum from periodontal and healthy sites. METHODS: Subgingival clinical samples from 50 periodontitis adult patients and 50 healthy subjects were analyzed. Both organisms were isolated using a trypticase soy agar-bacitracin-vancomycin (TSBV) medium and detected by PCR. Conventional biochemical tests were used for bacteria identification. RESULTS: A. actinomycetemcomitans and F. nucleatum were isolated in 18% and 20% of the patients, respectively, and in 2% and 24% of healthy subjects. Among A. actinomycetemcomitans isolates, biotype II was the most prevalent. Primer pair AA was 100% sensitive in the detection of A. actinomycetemcomitans from both subject groups. Primers ASH and FU were also 100% sensitive to detect this organism in healthy subject samples. Primer pair FN5047 was more sensitive to detect F. nucleatum in patients or in healthy samples than primer 5059S. Primers ASH and 5059S were more specific in the detection of A. actinomycetemcomitans and F. nucleatum, respectively, in patients and in healthy subject samples. CONCLUSIONS: PCR is an effective tool for detecting periodontal pathogens in subgingival samples, providing a faster and safer diagnostic tool of periodontal diseases. The method's sensitivity and specificity is conditioned by the choice of the set of primers used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To validate a new symphysis-fundal curve for screening fetal growth deviations and to compare its performance with the standard curve adopted by the Brazilian Ministry of Health. METHODS: Observational study including a total of 753 low-risk pregnant women with gestational age above 27 weeks between March to October 2006 in the city of João Pessoa, Northeastern Brazil. Symphisys-fundal was measured using a standard technique recommended by the Brazilian Ministry of Health. Estimated fetal weight assessed through ultrasound using the Brazilian fetal weight chart for gestational age was the gold standard. A subsample of 122 women with neonatal weight measurements was taken up to seven days after estimated fetal weight measurements and symphisys-fundal classification was compared with Lubchenco growth reference curve as gold standard. Sensitivity, specificity, positive and negative predictive values were calculated. The McNemar χ2 test was used for comparing sensitivity of both symphisys-fundal curves studied. RESULTS: The sensitivity of the new curve for detecting small for gestational age fetuses was 51.6% while that of the Brazilian Ministry of Health reference curve was significantly lower (12.5%). In the subsample using neonatal weight as gold standard, the sensitivity of the new reference curve was 85.7% while that of the Brazilian Ministry of Health was 42.9% for detecting small for gestational age. CONCLUSIONS: The diagnostic performance of the new curve for detecting small for gestational age fetuses was significantly higher than that of the Brazilian Ministry of Health reference curve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To develop and validate a short health literacy assessment tool for Portuguese-speaking adults. METHODS: The Short Assessment of Health Literacy for Portuguese-speaking Adults is an assessment tool which consists of 50 items that assess an individual's ability to correctly pronounce and understand common medical terms. We evaluated the instrument's psychometric properties in a convenience sample of 226 Brazilian older adults. Construct validity was assessed by correlating the tool scores with years of schooling, self-reported literacy, and global cognitive functioning. Discrimination validity was assessed by testing the tool's accuracy in detecting inadequate health literacy, defined as failure to fully understand standard medical prescriptions. RESULTS: Moderate to high correlations were found in the assessment of construct validity (Spearman's coefficients ranging from 0.63 to 0.76). The instrument showed adequate internal consistency (Cronbach's alpha=0.93) and adequate test-retest reliability (intraclass correlation coefficient=0.95). The area under the receiver operating characteristic curve for detection of inadequate health literacy was 0.82. A version consisting of 18 items was tested and showed similar psychometric properties. CONCLUSIONS: The instrument developed showed good validity and reliability in a sample of Brazilian older adults. It can be used in research and clinical settings for screening inadequate health literacy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT This study aimed to describe the digital disease detection and participatory surveillance in different countries. The systems or platforms consolidated in the scientific field were analyzed by describing the strategy, type of data source, main objectives, and manner of interaction with users. Eleven systems or platforms, developed from 1996 to 2016, were analyzed. There was a higher frequency of data mining on the web and active crowdsourcing as well as a trend in the use of mobile applications. It is important to provoke debate in the academia and health services for the evolution of methods and insights into participatory surveillance in the digital age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IIF in the detection of invasive and classic enteropathogenic E. coli and Shigella serotypes was compared with traditional coproculture methods. IIP results agreed with the coproculture findings in 128 out of 140 cases tested for enteropathogenic E. coli (91%) and in 108 out of 112 for Shigella (96%). All cases with positive reactions by coproculture were confirmed by IIP. In the control group it were obtained by IIF 12 cases with positive reactions for enteropathogenic E. coli and 4 cases for Shigella, including two cases of mixed infection by E. coli 026/Sh. dysenteriae and E. coli 0124/Sh. dysenteriae. It was discussed the high sensitivity and specificity of the IIF when compared with the traditional methods, being suggested that IIF is a valuable tool in epidemiological studies involving these organisms and an important aid in the stablishment of an early presumptive diagnosis of the acute infantile diarrhea.