124 resultados para comparison methods
em Scielo Saúde Pública - SP
Resumo:
Human respiratory syncytial virus (HRSV) causes severe infections among children and immunocompromised patients. We compared HRSV infections among Haematopoietic Stem Cell Transplant program (HSCT) patients and children using direct immunofluorescence (DFA), point-of-care RSV Bio Easy® and a polymerase chain reaction (PCR) assay. Overall, 102 samples from HSCT patients and 128 from children obtained positivity rate of 18.6% and 14.1% respectively. PCR sensitivity was highest mainly on samples collected after five days of symptoms onset. A combination of both DFA and reverse transcriptase-PCR methods for HSCT high-risk patients is the best diagnostic flow for HRSV diagnosis among these patients.
Resumo:
Signal processing methods based on the combined use of the continuous wavelet transform (CWT) and zero-crossing technique were applied to the simultaneous spectrophotometric determination of perindopril (PER) and indapamide (IND) in tablets. These signal processing methods do not require any priory separation step. Initially, various wavelet families were tested to identify the optimum signal processing giving the best recovery results. From this procedure, the Haar and Biorthogonal1.5 continuous wavelet transform (HAAR-CWT and BIOR1.5-CWT, respectively) were found suitable for the analysis of the related compounds. After transformation of the absorbance vectors by using HAAR-CWT and BIOR1.5-CWT, the CWT-coefficients were drawn as a graph versus wavelength and then the HAAR-CWT and BIOR1.5-CWT spectra were obtained. Calibration graphs for PER and IND were obtained by measuring the CWT amplitudes at 231.1 and 291.0 nm in the HAAR-CWT spectra and at 228.5 and 246.8 nm in BIOR1.5-CWT spectra, respectively. In order to compare the performance of HAAR-CWT and BIOR1.5-CWT approaches, derivative spectrophotometric (DS) method and HPLC as comparison methods, were applied to the PER-IND samples. In this DS method, first derivative absorbance values at 221.6 for PER and 282.7 nm for IND were used to obtain the calibration graphs. The validation of the CWT and DS signal processing methods was carried out by using the recovery study and standard addition technique. In the following step, these methods were successfully applied to the commercial tablets containing PER and IND compounds and good accuracy and precision were reported for the experimental results obtained by all proposed signal processing methods.
Resumo:
ABSTRACTAiming to compare three different methods for the determination of organic carbon (OC) in the soil and fractions of humic substances, seventeen Brazilian soil samples of different classes and textures were evaluated. Amounts of OC in the soil samples and the humic fractions were measured by the dichromate-oxidation method, with and without external heating in a digestion block at 130 °C for 30 min; by the loss-on-ignition method at 450 °C during 5 h and at 600 °C during 6 h; and by the dry combustion method. Dry combustion was used as reference in order to measure the efficiency of the other methods. Soil OC measured by the dichromate-oxidation method with external heating had the highest efficiency and the best results comparing to the reference method. When external heating was not used, the mean recovery efficiency dropped to 71%. The amount of OC was overestimated by the loss-on-ignition methods. Regression equations obtained between total OC contents of the reference method and those of the other methods showed relatively good adjustment, but all intercepts were different from zero (p < 0.01), which suggests that more accuracy can be obtained using not one single correction factor, but considering also the intercept. The Walkley-Black method underestimated the OC contents of the humic fractions, which was associated with the partial oxidation of the humin fraction. Better results were obtained when external heating was used. For the organic matter fractions, the OC in the humic and fulvic acid fractions can be determined without external heating if the reference method is not available, but the humin fraction requires the external heating.
Resumo:
ABSTRACT The objective of this work was to study the distribution of values of the coefficient of variation (CV) in the experiments of papaya crop (Carica papaya L.) by proposing ranges to guide researchers in their evaluation for different characters in the field. The data used in this study were obtained by bibliographical review in Brazilian journals, dissertations and thesis. This study considered the following characters: diameter of the stalk, insertion height of the first fruit, plant height, number of fruits per plant, fruit biomass, fruit length, equatorial diameter of the fruit, pulp thickness, fruit firmness, soluble solids and internal cavity diameter, from which, value ranges were obtained for the CV values for each character, based on the methodology proposed by Garcia, Costa and by the standard classification of Pimentel-Gomes. The results obtained in this study indicated that ranges of CV values were different among various characters, presenting a large variation, which justifies the necessity of using specific evaluation range for each character. In addition, the use of classification ranges obtained from methodology of Costa is recommended.
Resumo:
Respiratory virus infections are the main cause of infant hospitalization and are potentially severe in children with congenital heart disease (CHD). Rapid and sensitive diagnosis is very important to early introduction of antiviral treatment and implementation of precautions to control transmission, reducing the risk of nosocomial infections. In the present study we compare different techniques in the diagnosis of respiratory viruses in CHD infants. Thirty-nine samples of nasopharyngeal aspirate were obtained from CHD infants with symptoms of respiratory infection. The Multiplex PCR (Seeplex® RV 12 ACE Detection) driven to the detection of 12 respiratory viruses was compared with the direct immunofluorescence assay (DFA) and PCR, both targeting seven respiratory viruses. The positivity found by DFA, Multiplex and PCR was 33.3%, 51.3% and 48.7%, respectively. Kappa index comparing DFA and Multiplex, DFA and PCR and PCR and Multiplex PCR was 0.542, 0.483 and 0.539, respectively. The concordance between techniques was considered moderate. Both Multiplex PCR (p = 0.001) and PCR (p = 0.002) detected significantly more respiratory virus than DFA. As the performance of the tests may vary, the combination of two or more techniques may increase diagnostic sensitivity favoring the diagnosis of co-infections, early introduction of antiviral therapy and implementation of appropriate measures.
Resumo:
Methicillin-resistant Staphylococcus aureus (MRSA) are now a worldwide problem. Cystic fibrosis (CF) patients are commonly colonized and infected by MRSA. Accurate oxacillin susceptibility testing is mandatory for the adequate management of these patients. We performed a comparison of the accuracy of different tests in CF isolates, including methicillin-susceptible S. aureus and MRSA with different SCCmec types, and using the mecA gene as the gold-standard. The sensitivity and specificity of oxacillin disc, Etest, and oxacillin agar screening plate were 100%. Sensitivity of the cefoxitin disc was 85% and specificity was 100%. For clinically relevant isolates, laboratories may consider the use of a combination of two phenotypic methods.
Resumo:
SUMMARY Infection by Candidaspp. is associated with high mortality rates, especially when treatment is not appropriate and/or not immediate. Therefore, it is necessary to correctly identify the genus and species of Candida. The aim of this study was to compare the identification of 89 samples of Candida spp. by the manual methods germ tube test, auxanogram and chromogenic medium in relation to the ID 32C automated method. The concordances between the methods in ascending order, measured by the Kappa index were: ID 32C with CHROMagar Candida(κ = 0.38), ID 32C with auxanogram (κ = 0.59) and ID 32C with germ tube (κ = 0.9). One of the species identified in this study was C. tropicalis,which demonstrated a sensitivity of 46.2%, a specificity of 95.2%, PPV of 80%, NPV of 81.1%, and an accuracy of 80.9% in tests performed with CHROMagar Candida;and a sensitivity of 76.9%, a specificity of 96.8%, PPV of 90.9%, NPV of 91%, and an accuracy of 91% in the auxanogram tests. Therefore, it is necessary to know the advantages and limitations of methods to choose the best combination between them for a fast and correct identification of Candidaspecies.
Resumo:
Trichomonas vaginalis is the etiologic agent of trichomoniasis, the most common non-viral sexually transmitted disease (STD) in the world. The diagnosis is based on wet mount preparation and direct microscopy on fixed and stained clinical specimens. The aim of this study was to compare the performance of different fixing and staining techniques used in the detection of T. vaginalis in urine. The smears were fixed and submitted to different methods of permanent staining and then, the morphological aspects of the parasites were analyzed and compared. The Papanicolaou staining with ethanol as the fixative solution showed to be the best method of permanent staining. Our data suggest that staining techniques in association with wet mount examination of fresh specimens contribute to increase the sensitivity in the diagnosis of trichomoniasis.
Resumo:
Através da prova de 7 dias foi estudado o grau de resistência do Plasmodium falciparum à cloroquina, amodiaquina e sulfadoxina-pirimetamina em Porto Velho, Estado de Rondônia, Brasil. Não se observaram diferenças significativas nas médias de parasitas nos dias de seguimento e nas proporções de resistência entre os três medicamentos testados, fazendo com que os autores recomendem a manutenção das 4-aminoquinoleínas como drogas a serem usadas atualmente em infecções não graves por P. falciparum na área de Porto Velho.
Resumo:
The purpose of this study was to compare the agar dilution and broth microdilution methods for determining the minimum inhibitory concentration (MIC) of fluconazole, itraconazole, ketoconazole, griseofulvin and terbinafine for 60 dermatophyte samples belonging to the species Trichophyton rubrum, Trichophyton mentagrophytes and Microsporum canis. The percentage agreement between the two methods, for all the isolates with < 2 dilutions that were tested was 91.6% for ketoconazole and griseofulvin, 88.3% for itraconazole, 81.6% for terbinafine and 73.3% for fluconazole. One hundred percent agreement was obtained for Trichophyton mentagrophytes isolates evaluated with ketoconazole and griseofulvin. Thus, until a reference method for testing the in vitro susceptibility of dermatophytes is standardized, the similarity of the results between the two methods means that the agar dilution method may be useful for susceptibility testing on these filamentous fungi.
Resumo:
INTRODUCTION: The present study compares human landing catches of primary malaria vectors with two alternative methods of capture: the Shannon trap and the Mosquito magnet. METHODS: This study used regression models to adjust capture data to a negative binominal distribution. RESULTS: Capture numbers and relative percentages obtained from the three methods vary strongly between species. The highest overall captures were obtained for Anopheles triannulatus with captures for the Shannon trap and the Mosquito magnet measuring more than 330% higher than captures obtained by human landings. For Anopheles darlingi, captures by the Shannon trap and the Mosquito magnet were about 14% and 26% of human landing catches, respectively. Another species with malaria transmission potential that was not sampled by human landing captures weascaptured by the Shannon trap and the Mosquito magnet (Anopheles oswaldoi). Both alternative sampling techniques can predict the human landing of Anopheles triannulatus, but without proportionality. Models for Anopheles darlingi counts, after totaling daily captures, are significant and proportional, but prediction models are more reliable when using the Shannon trap compared with the Mosquito magnet captures. CONCLUSIONS: These alternative capture methods can be partially recommended for the substitution of human landing captures or, at least, as complementary forms of monitoring for malarial mosquitoes.
Resumo:
Introduction Trypanosoma cruzi, a flagellated protozoan, is the etiologic agent of Chagas disease, and it is estimated that approximately 5 million people in Brazil are infected with this parasite. This work aimed to compare the current diagnostic methods for Chagas disease, including conventional serological (IFAT and ELISA) and molecular techniques (PCR), to introduce PCR as an auxiliary technique. Methods A total of 106 chagasic patients were evaluated: 88 from endemic areas of Parana, 6 from São Paulo, 3 from Minas Gerais, 3 from Rio Grande do Sul, 1 from Bahia and 5 from the Santa Catarina T. cruzi outbreak. The samples were analyzed by conventional serological methods (IFAT, ELISA), hemoculture and PCR to confirm Chagas disease. Results When IFAT was used to determine antibody levels, the sensitivity was 81.7% for patients with the cardiac form of the disease and 100% for the other clinical forms. In contrast, ELISA showed 84% sensitivity and 100% specificity. The use of serological and molecular techniques and their implications for the diagnosis of Chagas disease in non-endemics area are discussed. Conclusions PCR constitutes an excellent support methodology for the laboratory diagnosis of Chagas disease due to its high sensitivity and specificity.
Resumo:
Background: Postprandial Lipemia (PPL) is a physiological process that reflects the ability of the body to metabolize lipids. Even though the influence of oral contraceptives (OC) on PPL is not known, it is a known fact that their use increases fasting lipid values. Objective: To compare the PPL between women who are on OC and those who are not. Methods: A prospective analytical study which assessed eutrophic women, aged between 18 and 28 years old, who were irregularly active and with fasting triglycerides ≤150 mg/dL. They were divided into two groups: oral contraceptive group (COG) and non-oral contraceptive group (NCOG). Volunteers were submitted to the PPL test, in which blood samples were collected in time 0 (12-hour fasting) and after the intake of lipids in times 180 and 240 minutes. In order to compare the triglyceride deltas, which reflect PPL, the two-tailed Mann-Whitney test was used for independent samples between fasting collections and 180 minutes (Δ1) and between fasting and 240 minutes (Δ2). Results: Forty women were assessed and equally divided between groups. In the fasting lipid profile, it was observed that HDL did not present significant differences and that triglycerides in COG were twice as high in comparison to NCOG. Medians of Δ1 and Δ2 presented significant differences in both comparisons (p ≤0.05). Conclusion: The results point out that women who are irregularly active and use OC present more PPL in relation to those who do not use OC, which suggests that in this population, its chronic use increases the risk of heart conditions.