2 resultados para center density

em Scielo Saúde Pública - SP


Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT One of the factors that can influence soybeans yield is the interference imposed by weeds. This research has aimed to determine the critical period of weed interference on cv. INT 6100 RRTM soybeans. The experiment was conducted under field conditions at Campo Mourão County, Parana State, in the 2013/2014 harvest, using randomized blocks, arranged in a 2 x 8 factorial, with four replications. In the first factor, the coexistence (period before weed interference) and control (total period of weed interference prevention) periods were assessed. The second factor consisted of management times of weed species (0, 7, 14, 28, 35, 49, 56 and 130 days after emergence - DAE). The evaluations performed were density and shoot dry matter of the weed community, height, number of pods, thousand grain weight and soybean yield. Among the weed species in soybean crops, there was predominance of eudicotyledonous ones (82%). The yield results allowed establishing, for cv. INT 6100 RRTM soybeans at Campo Mourão County, Parana State, a critical period for preventing interference between 24-38 DAE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Even though frequency analysis of body sway is widely applied in clinical studies, the lack of standardized procedures concerning power spectrum estimation may provide unreliable descriptors. Stabilometric tests were applied to 35 subjects (20-51 years, 54-95 kg, 1.6-1.9 m) and the power spectral density function was estimated for the anterior-posterior center of pressure time series. The median frequency was compared between power spectra estimated according to signal partitioning, sampling rate, test duration, and detrending methods. The median frequency reliability for different test durations was assessed using the intraclass correlation coefficient. When increasing number of segments, shortening test duration or applying linear detrending, the median frequency values increased significantly up to 137%. Even the shortest test duration provided reliable estimates as observed with the intraclass coefficient (0.74-0.89 confidence interval for a single 20-s test). Clinical assessment of balance may benefit from a standardized protocol for center of pressure spectral analysis that provides an adequate relationship between resolution and variance. An algorithm to estimate center of pressure power density spectrum is also proposed.