74 resultados para capillary filtration

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Campylobacter was isolated in 178 out of 622 stool samples (200 porcine, 220 bovine, and 202 canine). From these 178 samples, the microorganism was identified in 64 samples (36%) isolated only in Butzler selective medium (BSM), 34 samples (19%) using filtration technique (FT), and in 80 samples (45%) using both BSM and FT. Comparison of the proportion of positivity using both techniques showed a significant value (c2 = 9,184; p > 0.001); BSM (36%) being more efficient than FT (19%). The use of both techniques yielded the highest isolation positivity (45%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Since the launch of the Global Programme to Eliminate Lymphatic Filariasis, more than 70% of the endemic countries have implemented mass drug administration (MDA) to interrupt disease transmission. The monitoring of filarial infection in sentinel populations, particularly schoolchildren, is recommended to assess the impact of MDA. A key issue is choosing the appropriate tools for these initial assessments (to define the best intervention) and for monitoring transmission. Methods This study compared the pre-MDA performance of five diagnostic methods, namely, thick film test, Knott's technique, filtration, Og4C3-ELISA, and the AD12-ICT card test, in schoolchildren from Brazil. Venous and capillary blood samples were collected between 11 pm and 1 am. The microfilarial loads were analyzed with a negative binomial regression, and the prevalence and associated 95% confidence intervals were estimated for all methods. The accuracies of the AD12-ICT card and Og4C3-ELISA tests were assessed against the combination of parasitological test results. Results A total of 805 schoolchildren were examined. The overall and stratified prevalence by age group and gender detected by Og4C3-ELISA and AD12-ICT were markedly higher than the prevalence estimated by the parasitological methods. The sensitivity of the AD12-ICT card and Og4C3-ELISA tests was approximately 100%, and the positive likelihood ratios were above 6. The specificity of the Og4C3-ELISA was higher than that of the AD12-ICT at different prevalence levels. Conclusions The ICT card test should be the recommended tool for monitoring school-age populations living in areas with ongoing or completed MDA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluid management and dosage regimens of drugs in preterm infants should be based on the glomerular filtration rate. The current methods to determine glomerular flitration rate are invasive, time-consuming, and expensive. In contrast, creatinine clearance can be easy obtained and quickly determined. The purpose of this study was to compare plasma creatinine on the third and seventh day of life in preterm newborn infants, to evaluate the influence of maternal creatinine, and to demonstrate creatinine clearance can be used as a reliable indicator of glomerular filtration rate. We developed a prospective study (1994) including 40 preterm newborns (gestational age < 37 weeks), average = 34 weeks; birth weight (average) = 1840 g, in the first week of life. Inclusion criteria consisted of: absence of renal and urinary tract anomalies; O2 saturation 3 92%; adequate urine output (>1ml/kg/hr); normal blood pressure; absence of infections and no sympathomimetic amines in use. A blood sample was collected to determine plasma creatinine (enzymatic method) on the third and seventh day of life and creatinine clearance (CrCl) was obtained using the following equation: , k = 0.33 in preterm infant All plasma creatinine determinations showed normal values [third day: 0.78 mg/dl ± 0.24 (mean ± SD)and seventh day: 0.67 mg/dl ± 0.31 - (p>0.05)]. Also all creatinine clearance at third and seventh day of life were normal [third day: 19.5 ml/min ± 5.2 (mean ± SD) and seventh day: 23.8 ml/min ± 7.3 - (p>0,05)]. All preterm infants developed adequate renal function for their respective gestational age. In summary, our results indicate that, for clinical practice, the creatinine clearance, using newborn length, can be used to estimate glomerular filtration rate in preterm newborn infants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of illicit drugs such as cocaine and marijuana in US paper currency is very well demonstrated. However, there is no published study describing the presence of cocaine and/or other illicit drugs in Brazilian paper currency. In this study, Brazilian banknotes were collected from nine cities, extracted and analyzed by capillary gas chromatography/mass spectrometry, in order to investigate the presence of cocaine. Bills were extracted with deionized water followed by ethyl acetate. Results showed that 93% of the bills presented cocaine in a concentration range of 2.38-275.10 µg/bill.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the current study, an alternative method has been proposed for simultaneous analysis of palmitic, stearic, oleic, linoleic, and linolenic acids by capillary zone electrophoresis (CZE) using indirect detection. The background electrolyte (BGE) used for the analysis of these fatty acids (FAs) consisted of 15.0 mmol L−1 NaH2PO4/Na2HPO4 at pH 6.86, 4.0 mmol L−1 SDBS, 8.3 mmol L−1 Brij 35, 45% v/v acetonitrile (can), and 2.1% n-octanol. The FAs quantification of FAs was performed using a response factor approach, which provided a high analytical throughput for the real sample. The CZE method, which was applied successfully for the analysis of pequi pulp, has advantages such as short analysis time, absence of lipid fraction extraction and derivatization steps, and no significant difference in the 95% confidence intervals for FA quantification results, compared to the gas chromatography official method (AOCS Ce 1h-05).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organic extracts were obtained from roots of Canavalia ensiformis and evaluated for allelopathic potential on the germination of the weed seeds: Mimosa pudica, Cassia tora and Cassia occidentalis showing a strong allelopathic potential. After that, a systematic study of these crude extracts was made using specific protocols developed in capillary electrophoresis (CE) in order to determine some classes of secondary metabolites. Capillary electrophoresis protocols were highly specific, which makes it possible to identify 5 classes of compounds using the same crude extract samples and analyze them fartly. Some of the compounds identified show activity in the inhibition of seeds germination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with capacitively coupled contactless conductivity detection (C4D) was used for determination of sodium and potassium concentrations in diet and non-diet soft drinks. Higher sodium concentrations were found in the diet samples due to the utilization of sodium salts of cyclamate and saccharine as sweeteners. The CE-C4D method can be used by food industries and health regulatory agencies for monitoring sodium and potassium content, not only in soft drink but in many others food products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents an evaluation of a pilot multistage filtration system (MSF) with different dosages, 131 mg L-1 and 106 mg L-1, of the natural coagulant extracted from Moringa oleifera seeds in pre-filtration and slow filtration stages, respectively. The system was comprised by a dynamic pre-filter unit, two upflow filters in parallel and four slow filters in parallel, and in one of the four filters had the filter media altered. The performance of the system was evaluated by monitoring some water quality parameters such as: turbidity, apparent color and slow filter load loss. The stages that have received the coagulant solution had better treatment efficiency compared with the steps without it. However, the direct application of the coagulant solution in the slow filter caused rapid clogging of the non-woven blanket and shorter career length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of catecholamines in the distribution of intrarenal blood flow and in single-nephron glomerular filtration rate (SNGFR) was evaluated in anesthetized Wistar rats by the Hanssen technique. Epinephrine (EPI) and norepinephrine (NOR) were infused to produce elevations of 20-30 mmHg in mean arterial pressure. Superficial and juxtamedullary nephron perfusion and filtration were determined by the presence of Prussian blue dye. In the control group, 100% of the nephrons presented a homogeneous pattern of perfusion and filtration. In contrast, a heterogeneous distribution of the dye was found even in the larger arteries (arciform and radial), indicating variable perfusion and filtration in both superficial and juxtamedullary nephrons. The effects of EPI and NOR were also evaluated in the superficial cortex by the micropuncture technique in two additional groups of Munich-Wistar rats. Mean SNGFR was 27% and 54% lower in the EPI- and NOR-treated groups, respectively. No change in mean intraglomerular hydraulic pressure was observed after EPI or NOR infusion in spite of a highly scattered pattern, indicating an important variability in perfusion along the superficial cortex, and/or different sensitivity of the pre- and post-glomerular arterioles. The present data suggest that EPI and NOR may affect intrarenal hemodynamics by modifying perfusion and filtration in both superficial and juxtamedullary glomeruli and not by shifting blood flow from superficial to juxtamedullary nephrons. The heterogeneous pattern of perfusion was a consequence of differential vasoconstriction along the intrarenal arteries, probably due to different density and/or sensitivity of the adrenergic receptor subtypes present in the intrarenal vascular tree.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanical ventilation has been associated with organ failure in patients with acute respiratory distress syndrome. The present study examines the effects of tidal volume (V T) on renal function using two V T values (8 and 27 mL/kg) in anesthetized, paralyzed and mechanically ventilated male Wistar rats. Animals were randomized into two groups of 6 rats each: V T8 (V T, 8 mL/kg; 61.50 ± 0.92 breaths/min; positive end-expiratory pressure, 3.0 cmH2O; peak airway pressure (PAW), 11.8 ± 2.0 cmH2O), and V T27 (V T, 27 mL/kg; 33.60 ± 1.56 breaths/min; positive end-expiratory pressure, none, and PAW, 22.7 ± 4.0 cmH2O). Throughout the experiment, mean PAW remained comparable between the two groups (6.33 ± 0.21 vs 6.50 ± 0.22 cmH2O). For rats in the V T27 group, inulin clearance (mL·min-1·body weight-1) decreased acutely after 60 min of mechanical ventilation and even more significantly after 90 min, compared with baseline values (0.60 ± 0.05 and 0.45 ± 0.05 vs 0.95 ± 0.07; P < 0.001), although there were no differences between groups in mean arterial pressure or gasometric variables. In the V T8 group, inulin clearance at 120 min of mechanical ventilation remained unchanged in relation to baseline values (0.72 ± 0.03 vs 0.80 ± 0.05). The V T8 and V T27 groups did not differ in terms of serum thiobarbituric acid reactive substances (3.97 ± 0.27 vs 4.02 ± 0.45 nmol/mL) or endothelial nitric oxide synthase expression (94.25 ± 2.75 vs 96.25 ± 2.39%). Our results show that glomerular filtration is acutely affected by high tidal volume ventilation but do not provide information about the mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic kidney disease (CKD) is a world-wide public health problem, with adverse outcomes of kidney failure, cardiovascular disease, and premature death. This finding has led to the hypothesis that earlier recognition of kidney disease and successful intervention may improve outcome. The National Kidney Foundation, through its Kidney Disease Outcomes Quality Initiative (K/DOQI), and other National institutions recommend glomerular filtration rate (GFR) for the definition, classification, screening, and monitoring of CKD. Blood creatinine clearance, the most widely used clinical marker of kidney function, is now recognized as an unreliable measure of GFR because serum creatinine is affected by age, weight, muscle mass, race, various medications, and extra-glomerular elimination. Cystatin C concentration is a new and promising marker for kidney dysfunction in both native and transplanted kidneys. Because of its low molecular weight, cystatin C is freely filtered at the glomerulus and is almost completely reabsorbed and catabolized, but not secreted, by tubular cells. Given these characteristics, cystatin C concentration may be superior to creatinine concentration in detecting chronic kidney disease. This review aims to evaluate from recent literature the clinical efficiency and relevance of these GFR markers in terms of screening CKD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Decaffeinated coffee accounts for 10 percent of coffee sales in the world; it is preferred by consumers that do not wish or are sensitive to caffeine effects. This article presents an analytical comparison of capillary electrophoresis (CE) and high performance liquid chromatography (HPLC) methods for residual caffeine quantification in decaffeinated coffee in terms of validation parameters, costs, analysis time, composition and treatment of the residues generated, and caffeine quantification in 20 commercial samples. Both methods showed suitable validation parameters. Caffeine content did not differ statistically in the two different methods of analysis. The main advantage of the high performance liquid chromatography (HPLC) method was the 42-fold lower detection limit. Nevertheless, the capillary electrophoresis (CE) detection limit was 115-fold lower than the allowable limit by the Brazilian law. The capillary electrophoresis (CE) analyses were 30% faster, the reagent costs were 76.5-fold, and the volume of the residues generated was 33-fold lower. Therefore, the capillary electrophoresis (CE) method proved to be a valuable analytical tool for this type of analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evaluation of filtration methods on the yield and oleochemicals characteristics on the crude fish oil from the soapstock of marine fish for purposes of nutrition has been conducted in this work. The analytical properties of the crude and the neutralized oil with three excesses of sodium hydroxide (NaOH, 20%, 40% and 60%) were carried out on two different ways with organza and the “glass wool”. The neutralization of the oil brought about a notable improvement in the analytical properties of the oil. Thus, it leads to a high quality fish oil in terms of taste, colour, odours, shelf life and market value. Based on the improved characteristics of the oil, it could be suitable for applications in pharmaceutical and food industries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nitrogen has a complex dynamics in the soil-plant-atmosphere system. N fertilizers are subject to chemical and microbial transformations in soils that can result in significant losses. Considering the cost of fertilizers, the adoption of good management practices like fertigation could improve the N use efficiency by crops. Water balances (WB) were applied to evaluate fertilizer N leaching using 15N labeled urea in west Bahia, Brazil. Three scenarios (2008/2009) were established: i) rainfall + irrigation the full year, ii) rainfall only; and iii) rainfall + irrigation only in the dry season. The water excess was considered equal to the deep drainage for the very flat area (runoff = 0) with a water table located several meters below soil surface (capillary rise = 0). The control volume for water balance calculations was the 0 - 1 m soil layer, considering that it involves the active root system. The water drained below 1 m was used to estimate fertilizer N leaching losses. WB calculations used the mathematic model of Penman-Monteith for evapotranspiration, considering the crop coefficient equal to unity. The high N application rate associated to the high rainfall plus irrigation was found to be the main cause for leaching, which values were 14.7 and 104.5 kg ha-1 for the rates 400 and 800 kg ha-1 of N, corresponding to 3.7 and 13.1 % of the applied fertilizer, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To determine the precision and agreement of the hemoglobin (Hb) measurements in capillary and venous blood samples by the HemoCue® and an automated counter. Hb was determined by both equipaments in blood samples of 29 pregnant women. The HemoCue® showed low repeatability of Hb measurements in duplicate in capillary (CR=0.53 g/dL, CV=13.6%) and venous blood (CR=0.53 g/dL, CV=13.6%). Hb measurements in capillary blood were higher than those in venous blood (12.4 and 11.7 g/dL, respectively; p<0.05). There was high agreement between Hb in capillary blood by the HemoCue® and in venous blood by the counter (r icc=0.86; p<0.01), and also between the diagnosis of anemia by both equipments (k=0.81; p<0.01). The HemoCue® seems to be more appropriate for capillary blood and require training of the measurers.