37 resultados para automated semantic integration

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The article discusses if nationalism is getting in the way of regional integration through a Brazilian prism due to Brazil’s pivotal role in regional integration in Mercosur and South America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the purpose of at lowering costs and reendering the demanded information available to users with no access to the internet, service companies have adopted automated interaction technologies in their call centers, which may or may not meet the expectations of users. Based on different areas of knowledge (man-machine interaction, consumer behavior and use of IT) 13 propositions are raised and a research is carried out in three parts: focus group, field study with users and interviews with experts. Eleven automated service characteristics which support the explanation for user satisfaction are listed, a preferences model is proposed and evidence in favor or against each of the 13 propositions is brought in. With balance scorecard concepts, a managerial assessment model is proposed for the use of automated call center technology. In future works, the propositions may become verifiable hypotheses through conclusive empirical research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The correct identification of the underlying cause of death and its precise assignment to a code from the International Classification of Diseases are important issues to achieve accurate and universally comparable mortality statistics These factors, among other ones, led to the development of computer software programs in order to automatically identify the underlying cause of death. OBJECTIVE: This work was conceived to compare the underlying causes of death processed respectively by the Automated Classification of Medical Entities (ACME) and the "Sistema de Seleção de Causa Básica de Morte" (SCB) programs. MATERIAL AND METHOD: The comparative evaluation of the underlying causes of death processed respectively by ACME and SCB systems was performed using the input data file for the ACME system that included deaths which occurred in the State of S. Paulo from June to December 1993, totalling 129,104 records of the corresponding death certificates. The differences between underlying causes selected by ACME and SCB systems verified in the month of June, when considered as SCB errors, were used to correct and improve SCB processing logic and its decision tables. RESULTS: The processing of the underlying causes of death by the ACME and SCB systems resulted in 3,278 differences, that were analysed and ascribed to lack of answer to dialogue boxes during processing, to deaths due to human immunodeficiency virus [HIV] disease for which there was no specific provision in any of the systems, to coding and/or keying errors and to actual problems. The detailed analysis of these latter disclosed that the majority of the underlying causes of death processed by the SCB system were correct and that different interpretations were given to the mortality coding rules by each system, that some particular problems could not be explained with the available documentation and that a smaller proportion of problems were identified as SCB errors. CONCLUSION: These results, disclosing a very low and insignificant number of actual problems, guarantees the use of the version of the SCB system for the Ninth Revision of the International Classification of Diseases and assures the continuity of the work which is being undertaken for the Tenth Revision version.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine the precision and agreement of the hemoglobin (Hb) measurements in capillary and venous blood samples by the HemoCue® and an automated counter. Hb was determined by both equipaments in blood samples of 29 pregnant women. The HemoCue® showed low repeatability of Hb measurements in duplicate in capillary (CR=0.53 g/dL, CV=13.6%) and venous blood (CR=0.53 g/dL, CV=13.6%). Hb measurements in capillary blood were higher than those in venous blood (12.4 and 11.7 g/dL, respectively; p<0.05). There was high agreement between Hb in capillary blood by the HemoCue® and in venous blood by the counter (r icc=0.86; p<0.01), and also between the diagnosis of anemia by both equipments (k=0.81; p<0.01). The HemoCue® seems to be more appropriate for capillary blood and require training of the measurers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enterococci are increasingly responsible for nosocomial infections worldwide. This study was undertaken to compare the identification and susceptibility profile using an automated MicrosScan system, PCR-based assay and disk diffusion assay of Enterococcus spp. We evaluated 30 clinical isolates of Enterococcus spp. Isolates were identified by MicrosScan system and PCR-based assay. The detection of antibiotic resistance genes (vancomycin, gentamicin, tetracycline and erythromycin) was also determined by PCR. Antimicrobial susceptibilities to vancomycin (30 µg), gentamicin (120 µg), tetracycline (30 µg) and erythromycin (15 µg) were tested by the automated system and disk diffusion method, and were interpreted according to the criteria recommended in CLSI guidelines. Concerning Enterococcus identification the general agreement between data obtained by the PCR method and by the automatic system was 90.0% (27/30). For all isolates of E. faecium and E. faecalis we observed 100% agreement. Resistance frequencies were higher in E. faecium than E. faecalis. The resistance rates obtained were higher for erythromycin (86.7%), vancomycin (80.0%), tetracycline (43.35) and gentamicin (33.3%). The correlation between disk diffusion and automation revealed an agreement for the majority of the antibiotics with category agreement rates of > 80%. The PCR-based assay, the van(A) gene was detected in 100% of vancomycin resistant enterococci. This assay is simple to conduct and reliable in the identification of clinically relevant enterococci. The data obtained reinforced the need for an improvement of the automated system to identify some enterococci.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The aim of this study was to assess the epidemiological and operational characteristics of the Leprosy Program before and after its integration into the Primary healthcare Services of the municipality of Aracaju-Sergipe, Brazil. METHODS: Data were drawn from the national database. The study periods were divided into preintegration (1996-2000) and postintegration (2001-2007). Annual rates of epidemiological detection were calculated. Frequency data on clinico-epidemiological variables of cases detected and treated for the two periods were compared using the Chi-squared (χ2) test adopting a 5% level of significance. RESULTS: Rates of detection overall, and in subjects younger than 15 years, were greater for the postintegration period and were higher than rates recorded for Brazil as a whole during the same periods. A total of 780 and 1,469 cases were registered during the preintegration and postintegration periods, respectively. Observations for the postintegration period were as follows: I) a higher proportion of cases with disability grade assessed at diagnosis, with increase of 60.9% to 78.8% (p < 0.001), and at end of treatment, from 41.4% to 44.4% (p < 0.023); II) an increase in proportion of cases detected by contact examination, from 2.1% to 4.1% (p < 0.001); and III) a lower level of treatment default with a decrease from 5.64 to 3.35 (p < 0.008). Only 34% of cases registered from 2001 to 2007 were examined. CONCLUSIONS: The shift observed in rates of detection overall, and in subjects younger than 15 years, during the postintegration period indicate an increased level of health care access. The fall in number of patients abandoning treatment indicates greater adherence to treatment. However, previous shortcomings in key actions, pivotal to attaining the outcomes and impact envisaged for the program, persisted in the postintegration period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Enterobacteriaceae strains are a leading cause of bloodstream infections (BSI). The aim of this study is to assess differences in clinical outcomes of patients with BSI caused by Enterobacteriaceae strains before and after introduction of an automated microbiologic system by the microbiology laboratory. METHODS: We conducted a retrospective cohort study aimed to evaluate the impact of the introduction of an automated microbiologic system (Phoenix(tm) automated microbiology system, Becton, Dickinson and Company (BD) - Diagnostic Systems, Sparks, MD, USA) on the outcomes of BSIs caused by Enterobacteriaceae strains. The study was undertaken at Hospital São Paulo, a 750-bed teaching hospital in São Paulo, Brazil. Patients with BSI caused by Enterobacteriaceae strains before the introduction of the automated system were compared with patients with BSI caused by the same pathogens after the introduction of the automated system with regard to treatment adequacy, clinical cure/improvement and 14- and 28-day mortality rates. RESULTS: We evaluated 90 and 106 patients in the non-automated and automated testing periods, respectively. The most prevalent species in both periods were Klebsiella spp. and Proteus spp. Clinical cure/improvement occurred in 70% and 67.9% in non-automated and automated period, respectively (p=0.75). 14-day mortality rates were 22.2% and 30% (p=0.94) and 28-day mortality rates were 24.5% and 40.5% (p= 0.12). There were no significant differences between the two testing periods with regard to treatment adequacy, clinical cure/improvement and 14- and 28-day mortality rates. CONCLUSIONS: Introduction of the BD Phoenix(tm) automated microbiology system did not impact the clinical outcomes of BSIs caused by Enterobacteriaceae strains in our setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The association between leprosy and pregnancy is currently poorly understood and has been linked to serious clinical consequences. Methods A retrospective study between 2007 and 2009 was performed in the integration region of Carajás, Brazil on a population of pregnant lepers, with non-lepers of ages 12-49 years serving as the reference population. Results Twenty-nine pregnant lepers were studied during the study period. The detection rates (DRs) for the studied association were 4.7 in 2007, 9.4 in 2008, and 4.3 in 2009. Conclusions The Carajás region presented a medium pattern of endemicity during most of the study period, with a high DR found in 2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To make individual assessments using automated quantification methodology in order to screen for perfusion abnormalities in cerebral SPECT examinations among a sample of subjects with OCD. METHODS: Statistical parametric mapping (SPM) was used to compare 26 brain SPECT images from patients with OCD individually with an image bank of 32 normal subjects, using the statistical threshold of p < 0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). The maps were analyzed, and regions presenting voxels that remained above this threshold were sought. RESULTS: Six patients from a sample of 26 OCD images showed abnormalities at cluster or voxel level, considering the criteria described above, which represented 23.07%. However, seven images from the normal group of 32 were also indicated as cases of perfusional abnormality, representing 21.8% of the sample. CONCLUSION: The automated quantification method was not considered to be a useful tool for clinical practice, for analyses complementary to visual inspection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After the incorporation of automated external defibrilators by other airlines and the support of the Brazilian Society of cardiology, Varig Airlines Began the onboard defibrilation program with the initial purpose of equiping wide-body aircrafts frequently used in international flights and that airplanes use in the Rio - São Paulo route. With all fight attendants trained, the automated. External defibrilation devides were incorporated to 34 airplanes of a total pleet of 80 aircrats. The devices were intalled in the bagage compartments secured with velero straps and 2 pairs of electrods, one or which pre-conected to the device to minimize application time. Later, a portable monitor was addres to the ressocitation kit in the long flights. The expansion of the knowledge of the basic life support fundamentors and the correted implantation of the survival chain and of the automated external defibrilators will increase the extense of recovery of cardiorespiratory arrest victins in aircrafts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integration of kDNA sequences within the genome of the host cell shown by PCR amplification with primers to the conserved Trypanosoma cruzi kDNA minicircle sequence was confirmed by Southern hybridization with specific probes. The cells containing the integrated kDNA sequences were then perpetuated as transfected macrophage subclonal lines. The kDNA transfected macrophages expressed membrane antigens that were recognized by antibodies in a panel of sera from ten patients with chronic Chagas disease. These antigens barely expressed in the membrane of uninfected, control macrophage clonal lines were recognized neither by factors in the control, non-chagasic subjects nor in the chagasic sera. This finding suggests the presence of an autoimmune antibody in the chagasic sera that recognizes auto-antigens in the membrane of T. cruzi kDNA transfected macrophage subclonal lines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coagulase-negative staphylococci (CoNS) are an important cause of nosocomial bacteremia, specially in patients with indwelling devices or those submitted to invasive medical procedures. The identification of species and the accurate and rapid detection of methicillin resistance are directly dependent on the quality of the identification and susceptibility tests used, either manual or automated. The objective of this study was to evaluate the accuracy of two automated systems MicroScan and Vitek - in the identification of CoNS species and determination of susceptibility to methicillin, considering as gold standard the biochemical tests and the characterization of the mecA gene by polymerase chain reaction, respectively. MicroScan presented better results in the identification of CoNS species (accuracy of 96.8 vs 78.8%, respectively); isolates from the following species had no precise identification: Staphylococcus haemolyticus, S. simulans, and S. capitis. Both systems were similar in the characterization of methicillin resistance. The higher discrepancies for gene mec detection were observed among species other than S. epidermidis (S. hominis, S. saprophyticus, S. sciuri, S. haemolyticus, S. warneri, S. cohnii), and those with borderline MICs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study aimed at understanding the implications of the teaching-service integration to nursing education from the perspective of teachers, students and professionals in Primary Healthcare as well as identifying the roles of teachers and professionals who follow practical experiences in education. This is a case study of qualitative approach carried out in five undergraduate courses in Nursing in the state of Santa Catarina. A total of 22 teachers and 14 professionals were interviewed and five focus groups were conducted with students. Results are presented in two categories: Implications of the teaching-service integration to education in Nursing: contributing factors and intervening factors and Relationships established in the experiences: a unison speech and a dissonant practice. The contributions of the teaching-service integration are undeniable. Despite this belief, there are intervening factors that need to be on the agenda for discussion. The role of facilitator in education emerged strongly despite conflicting perceptions remain.