3 resultados para Waveforms

em Scielo Saúde Pública - SP


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to establish normal reference electrocardiographic (ECG) values for standard limb lead II in Saanen goats. For this, were used 19 healthy adult female Saanen goats. And for reference values for the ECG parameters, were used 95% confidence level. The overall P, Q, R, S and T durations (seconds) were 0.03±0.01, 0.02±0.005, 0.03±0.014, 0.03±0.011, 0.06±0.014 respectively, and the reference values were 0.01-0.04, 0.01-0.02, 0.01-0.06, 0.02-0.04 and 0.04-0.08 respectively. The amplitudes (milivolts) of these waveforms were 0.1±0.031, 0.06±0.023, 0.44±0.312, 0.39±0.434, 0.26±0.164 (T negative) and 0.15±0.071 (T positive), respectively. The reference values were 0.05-0.15, 0.05-0.1, 0.05-1.2, 0.05-1.1 and -0.2-0.7 respectively. The PR and QT interval, the QRS complex and the ST segment durations (seconds) were 0.08±0.018, 0.26±0.03, 0.05±0.008, 0.15±0.041 respectively. The reference values were 0.06-0.12, 0.2-0.32, 0.04-0.07 and 0.11-0.26, respectively. It was possible to observe differences in ECG of Saanen goats regarding the amplitude and duration of the constituents when compared to the results of other breeds. Therefore it is necessary to conduct further studies to allow comparisons, detect and diagnose cardiac arrhythmias and help the development of therapies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An interesting fact about language cognition is that stimulation involving incongruence in the merge operation between verb and complement has often been related to a negative event-related potential (ERP) of augmented amplitude and latency of ca. 400 ms - the N400. Using an automatic ERP latency and amplitude estimator to facilitate the recognition of waves with a low signal-to-noise ratio, the objective of the present study was to study the N400 statistically in 24 volunteers. Stimulation consisted of 80 experimental sentences (40 congruous and 40 incongruous), generated in Brazilian Portuguese, involving two distinct local verb-argument combinations (nominal object and pronominal object series). For each volunteer, the EEG was simultaneously acquired at 20 derivations, topographically localized according to the 10-20 International System. A computerized routine for automatic N400-peak marking (based on the ascendant zero-cross of the first waveform derivative) was applied to the estimated individual ERP waveform for congruous and incongruous sentences in both series for all ERP topographic derivations. Peak-to-peak N400 amplitude was significantly augmented (P < 0.05; one-sided Wilcoxon signed-rank test) due to incongruence in derivations F3, T3, C3, Cz, T5, P3, Pz, and P4 for nominal object series and in P3, Pz and P4 for pronominal object series. The results also indicated high inter-individual variability in ERP waveforms, suggesting that the usual procedure of grand averaging might not be considered a generally adequate approach. Hence, signal processing statistical techniques should be applied in neurolinguistic ERP studies allowing waveform analysis with low signal-to-noise ratio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.