65 resultados para Visual Function
em Scielo Saúde Pública - SP
Resumo:
To quantify the effects of methylmercury (MeHg) on amacrine and on ON-bipolar cells in the retina, experiments were performed in MeHg-exposed groups of adult trahiras (Hoplias malabaricus) at two dose levels (2 and 6 µg/g, ip). The retinas of test and control groups were processed by mouse anti-parvalbumin and rabbit anti-alphaprotein kinase C (alphaPKC) immunocytochemistry. Morphology and soma location in the inner nuclear layer were used to identify immunoreactive parvalbumin (PV-IR) and alphaPKC (alphaPKC-IR) in wholemount preparations. Cell density, topography and isodensity maps were estimated using confocal images. PV-IR was detected in amacrine cells in the inner nuclear layer and in displaced amacrine cells from the ganglion cell layer, and alphaPKC-IR was detected in ON-bipolar cells. The MeHg-treated group (6 µg/g) showed significant reduction of the ON-bipolar alphaPKC-IR cell density (mean density = 1306 ± 393 cells/mm²) compared to control (1886 ± 892 cells/mm²; P < 0.001). The mean densities found for amacrine PV-IR cells in MeHg-treated retinas were 1040 ± 56 cells/mm² (2 µg/g) and 845 ± 82 cells/mm² (6 µg/g), also lower than control (1312 ± 31 cells/mm²; P < 0.05), differently from the data observed in displaced PV-IR amacrine cells. These results show that MeHg changed the PV-IR amacrine cell density in a dose-dependent way, and reduced the density of alphaKC-IR bipolar cells at the dose of 6 µg/g. Further studies are needed to identify the physiological impact of these findings on visual function.
Resumo:
Methyl mercury (MeHg) is highly neurotoxic, affecting visual function in addition to other central nervous system functions. The effect of mercury intoxication on the amplitude of horizontal cell responses to light was studied in the retina of the fish Hoplias malabaricus. Intracellular responses were recorded from horizontal cells of fish previously intoxicated with MeHg by intraperitoneal injection (IP group) or by trophic exposure (T group). Only one retina per fish was used. The doses of MeHg chloride administered to the IP group were 0.01, 0.05, 0.1, 1.0, 2.0, and 6.0 mg/kg. The amplitudes of the horizontal cell responses were lower than control in individuals exposed to 0.01 (N = 4 retinas), 0.05 (N = 2 retinas) and 0.1 mg/kg (N = 1 retina), whereas no responses were recorded in the 1.0, 2.0, and 6.0 mg/kg groups. T group individuals were fed young specimens of Astyanax sp previously injected with MeHg corresponding to 0.75 (N = 1 retina), 0.075 (N = 8 retinas) or 0.0075 (N = 4 retinas) mg/kg fish body weight. After 14 doses, one every 5 days, the amplitude of the horizontal cell response was higher than control in individuals exposed to 0.075 and 0.0075 mg/kg, and lower in individuals exposed to 0.75 mg/kg. We conclude that intoxication with MeHg affects the electrophysiological response of the horizontal cells in the retina, either reducing or increasing its amplitude compared to control, and that these effects are related to the dose and/or to the mode of administration.
Differential effects of aging on spatial contrast sensitivity to linear and polar sine-wave gratings
Resumo:
Changes in visual function beyond high-contrast acuity are known to take place during normal aging. We determined whether sensitivity to linear sine-wave gratings and to an elementary stimulus preferentially processed in extrastriate areas could be distinctively affected by aging. We measured spatial contrast sensitivity twice for concentric polar (Bessel) and vertical linear gratings of 0.6, 2.5, 5, and 20 cycles per degree (cpd) in two age groups (20-30 and 60-70 years). All participants were free of identifiable ocular disease and had normal or corrected-to-normal visual acuity. Participants were more sensitive to Cartesian than to polar gratings in all frequencies tested, and the younger adult group was more sensitive to all stimuli tested. Significant differences between sensitivities of the two groups were found for linear (only 20 cpd; P<0.01) and polar gratings (all frequencies tested; P<0.01). The young adult group was significantly more sensitive to linear than to circular gratings in the 20 cpd frequency. The older adult group was significantly more sensitive to linear than to circular gratings in all spatial frequencies, except in the 20 cpd frequency. The results suggest that sensitivity to the two kinds of stimuli is affected differently by aging. We suggest that neural changes in the aging brain are important determinants of this difference and discuss the results according to current models of human aging.
Resumo:
INTRODUCTION: This study evaluated the degree of disability, pain levels, muscle strength, and electromyographic function (RMS) in individuals with leprosy. METHODS: We assessed 29 individuals with leprosy showing common peroneal nerve damage and grade 1 or 2 disability who were referred for physiotherapeutic treatment, as well as a control group of 19 healthy participants without leprosy. All subjects underwent analyses of degree of disability, electromyographic tests, voluntary muscle force, and the Visual Analog Pain Scale. RESULTS: McNemar's test found higher levels of grade 2 of disability (Δ = 75.9%; p = 0.0001) among individuals with leprosy. The Mann-Whitney test showed greater pain levels (Δ = 5.0; p = 0.0001) in patients with leprosy who had less extension strength in the right and left extensor hallucis longus muscles (Δ = 1.28, p = 0.0001; Δ = 1.55, p = 0.0001, respectively) and dorsiflexion of the right and left feet (Δ = 1.24, p = 0.0001; Δ = 1.45, p = 0.0001, respectively) than control subjects. The Kruskal-Wallis test showed that the RMS score for dorsiflexion of the right (Δ = 181.66 m·s-2, p = 0.001) and left (Δ = 102.57m·s-2, p = 0.002) feet was lower in patients with leprosy than in control subjects, but intragroup comparisons showed no difference. CONCLUSIONS: Leprosy had a negative influence on all of the study variables, indicating the need for immediate physiotherapeutic intervention in individuals with leprosy. This investigation opens perspectives for future studies that analyze leprosy treatment with physical therapeutic intervention.
Resumo:
Simple reaction time (SRT) in response to visual stimuli can be influenced by many stimulus features. The speed and accuracy with which observers respond to a visual stimulus may be improved by prior knowledge about the stimulus location, which can be obtained by manipulating the spatial probability of the stimulus. However, when higher spatial probability is achieved by holding constant the stimulus location throughout successive trials, the resulting improvement in performance can also be due to local sensory facilitation caused by the recurrent spatial location of a visual target (position priming). The main objective of the present investigation was to quantitatively evaluate the modulation of SRT by the spatial probability structure of a visual stimulus. In two experiments the volunteers had to respond as quickly as possible to the visual target presented on a computer screen by pressing an optic key with the index finger of the dominant hand. Experiment 1 (N = 14) investigated how SRT changed as a function of both the different levels of spatial probability and the subject's explicit knowledge about the precise probability structure of visual stimulation. We found a gradual decrease in SRT with increasing spatial probability of a visual target regardless of the observer's previous knowledge concerning the spatial probability of the stimulus. Error rates, below 2%, were independent of the spatial probability structure of the visual stimulus, suggesting the absence of a speed-accuracy trade-off. Experiment 2 (N = 12) examined whether changes in SRT in response to a spatially recurrent visual target might be accounted for simply by sensory and temporally local facilitation. The findings indicated that the decrease in SRT brought about by a spatially recurrent target was associated with its spatial predictability, and could not be accounted for solely in terms of sensory priming.
Resumo:
Although healthy preterm infants frequently seem to be more attentive to visual stimuli and to fix on them longer than full-term infants, no difference in visual acuity has been reported compared to term infants. We evaluated the contrast sensitivity (CS) function of term (N = 5) and healthy preterm (N = 11) infants at 3 and 10 months of life using sweep-visual evoked potentials. Two spatial frequencies were studied: low (0.2 cycles per degrees, cpd) and medium (4.0 cpd). The mean contrast sensitivity (expressed in percentage of contrast) of the preterm infants at 3 months was 55.4 for the low spatial frequency (0.2 cpd) and 43.4 for the medium spatial frequency (4.0 cpd). At 10 months the low spatial CS was 52.7 and the medium spatial CS was 9.9. The results for the term infants at 3 months were 55.1 for the low spatial frequency and 34.5 for the medium spatial frequency. At 10 months the equivalent values were 54.3 and 14.4, respectively. No difference was found using the Mann-Whitney rank sum T-test between term and preterm infants for the low frequency at 3 or 10 months or for the medium spatial frequency at 3 or 10 months. The development of CS for the medium spatial frequency was equally fast for term and preterm infants. As also observed for visual acuity, CS was equivalent among term and preterm infants, suggesting that visual experience does not modify the development of the primary visual pathway. An earlier development of synapses in higher cortical visual areas of preterm infants could explain the better use of visual information observed behaviorally in these infants.
Resumo:
The objective of the present study was to determine contrast sensitivity curves of concentric circular patterns with radial frequencies of 0.25, 0.5, 1.0, 2.0, and 4.0 cycles per degree in young and older adult volunteers. These parameters were also compared with sensitivity contrasts for sine-wave gratings. All participants had normal acuity vision and were free of identifiable ocular illness. Contrast sensitivity was measured in 6 young adults aged 19 to 23 years and 6 older adults aged 60 to 69 years using the psychophysical forced-choice method. In this paradigm the volunteers had to decide which of two stimuli contained the above radial frequencies at low contrast levels. The other neutral stimulus was gray with homogeneous luminance. We detected a decline in contrast sensitivity for older adults at all radial frequencies compared to young adults. Also, contrast sensitivity for sine-wave gratings at all measured frequencies was better, as predicted, for all young adults. Maximum sensitivities in the radial frequency contrast sensitivity function and contrast sensitivity function occurred at 0.25 and 0.5 cycles per degree, respectively, for both young and older adults. These results suggest age-related changes in the contrast sensitivity function for concentric symmetrical stimuli.
Resumo:
Previous assessment of verticality by means of rod and rod and frame tests indicated that human subjects can be more (field dependent) or less (field independent) influenced by a frame placed around a tilted rod. In the present study we propose a new approach to these tests. The judgment of visual verticality (rod test) was evaluated in 50 young subjects (28 males, ranging in age from 20 to 27 years) by randomly projecting a luminous rod tilted between -18 and +18° (negative values indicating left tilts) onto a tangent screen. In the rod and frame test the rod was displayed within a luminous fixed frame tilted at +18 or -18°. Subjects were instructed to verbally indicate the rod’s inclination direction (forced choice). Visual dependency was estimated by means of a Visual Index calculated from rod and rod and frame test values. Based on this index, volunteers were classified as field dependent, intermediate and field independent. A fourth category was created within the field-independent subjects for whom the amount of correct guesses in the rod and frame test exceeded that of the rod test, thus indicating improved performance when a surrounding frame was present. In conclusion, the combined use of subjective visual vertical and the rod and frame test provides a specific and reliable form of evaluation of verticality in healthy subjects and might be of use to probe changes in brain function after central or peripheral lesions.
Resumo:
The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus.
Resumo:
Um dos tópicos mais questionado nos estudos clínicos sobre zumbido é o método de mensuração do mesmo. As Escalas Visual-Análogas (EVAs) e o Tinnitus Handicap Inventory (THI) são freqüentemente utilizados para este fim. OBJETIVO: Verificar a correlação entre os escores da EVA e do THI em pacientes com zumbido neurossensorial através de um estudo prospectivo. MATERIAL E MÉTODO: 43 pacientes com zumbido neurossensorial quantificaram o zumbido pelos dois métodos, sendo os escores comparados através do Coeficiente de Relação de Spearman. RESULTADOS: Foi observada correlação entre os escores da EVA e do THI. CONCLUSÃO: Em pacientes com zumbido neurossensorial existe correlação entre os escores da EVA e do THI.
Resumo:
Sistemas sustentáveis de produção agropecuária demandam solos com boa estrutura, por isso, são necessários métodos eficientes para avaliação dessa estrutura. Objetivou-se, com este estudo, aplicar a metodologia de avaliação visual da estrutura do solo, em áreas previamente cobertas por Floresta com Araucária, em longo período de uso após o desmatamento. Selecionaram-se áreas sob três tipos de usos: floresta nativa, pastagem e cultivo agrícola, considerados como tratamento, sendo realizadas dez amostragens por tipo de uso. Nas amostras coletadas, procedeu-se à avaliação da qualidade da estrutura do solo, seguida da análise estatística dos dados, por meio da análise de variância e do teste de separação de médias. Observaram-se diferenças significativas nos valores médios de escore entre as áreas avaliadas. Os solos da área com floresta apresentaram Qe (Qualidade visual) médio = 1.68, estatisticamente semelhante ao dos solos sob pastagem (Qe médio = 2.25) e inferior ao dos solos cultivados, Qe médio = 2.40. Os valores de Qe obtidos por avaliação visual da qualidade da estrutura do solo mostraram-se eficientes para identificar diferenças entre os sistemas de uso do solo.
Options listing and the volatility of the underling asset: a study on the derivative market function
Resumo:
There are basic misunderstandings on derivative markets. Some professionals believe that they are a kind of casinos and have no utility for the investors. This work looks at the effects of options introduction in the Brazilian market, seeking for another benefit for this introduction: changes in the stocks risk leveI. Our results are the same found in the US and other markets: the options introduction reduces the stocks volatility. We also found that there is a slight indication that the volatility becames more stochastic with this alternative.
Resumo:
ABSTRACT In this study, we demonstrate that the art infusion effect, in which the presence of visual art causes a positive impact on consumers' perceptions of products and advertising messages, might have a moderation effect on regulatory fit and non-fit messages. We investigate the impact of visual art on advertisement evaluations in regulatory (non-) fit conditions. Regulatory focus theory suggests that consumers rely on their motivational focus (prevention vs. promotion) for their evaluations and decisions. Usually, consumers prefer products that fit with their personal motivational focus. In the present study, the results of three experiments indicate that using visual art with a promotion or prevention fit message is recommended, while non-art images increase message persuasiveness when non-fit messages are presented. Therefore, not all information compatible with the consumer's motivational focus are best evaluated. When non-art images are presented, non-fit messages might be more persuasive.
Resumo:
A antropologia visual nasceu em meados do século XIX com a "era da reprodutibilidade técnica" e da expansão industrial. Como se reformula hoje, na era da globalização e da transformação digital, essa disciplina ou convergência disciplinar? Voltada inicialmente para a documentação e preservação de práticas culturais ameaçadas, a antropologia de urgência, como se transformou ao longo do tempo em formas narrativas visuais, sonoras, audiovisuais e, mais recentemente, digitais? Orientada em primeiros passos para alimentar e enriquecer as coleções dos museus, como passa hoje por meio de múltiplas formas e suportes para o espaço público à procura de novos espectadores/atores (ou públicos)? Inicialmente instrumentação que pareceria garantir a objetividade, atribuindo-se-lhe o estatuto de tecnologia de pesquisa ou mesmo de auxiliar de pesquisa, como se confrontou com novos paradigmas epistemológicos ou se antecipou a eles? Voltada sobretudo para o registo das técnicas materiais e rituais e depois para as palavras e as sonoridades, como se orienta hoje no âmbito de novos objetos de estudo como a antropologia da arte, a antropologia do design, a cultura visual em contextos de processos acelerados de transformação social e cultural? Acrescentamos ainda mais duas perguntas às inquietações que nos fazem refletir sobre essa temática: como se repensa atualmente a antropologia visual no âmbito da antropologia? O que fazer com a antropologia visual hoje? Procuraremos traçar algumas formas de práticas antigas que adquirem nova e maior pertinência na era atual (trabalho com os arquivos, a memória, a relação entre o passado e o projeto, os objetos, a cultura material) e perspectivar novas oportunidades, novas práticas, novos objetos de estudo.
Resumo:
Trata-se de avaliação da medida da acuidade visual pelo professor, comparativamente àquela efetuada pelo médico-oftalmologista, utilizando-se ambos da tabela optométrica de Snellen. Éste estudo foi realizado em decorrência do Plano de Oftalmologia Sanitária Escolar (POSE), em desenvolvimento no Estado de São Paulo, que atinge escolares de 1ª série, classe especial e pré-primário das escolas estaduais de 1º grau, onde a atuação dos professores constitui fator básico da programação, principalmente no seu aspecto educativo e na verificação da acuidade visual. Foram testados 1.352 escolares de 1ª a 4ª série de 1º grau de um estabelecimento de ensino do município de São Paulo (SP) em 1975. Encontrou-se uma concordância de resultados em 80,86% dos casos. Com a diferença de 2 linhas entre os resultados do professor e do médico, constataram-se 122 casos (9,02%) e, com a diferença de 3 linhas, 54 casos (3,99%). À medida em que se consideravam diferenças maiores, decrescia progressivamente o número de casos discordantes encontrados. Observou-se que, à medida em que aumentava a desigualdade de aferição entre o professor e o oftalmologista, isto se verificava em ambos os olhos, o que evidencia uma dificuldade de interpretação daquelas crianças para responder o teste. Considerou-se altamente válida a aplicação do teste de acuidade visual pelo professor devidamente treinado, com a finalidade de triagem a nível de escola, como um dos aspectos para identificar alunos necessitados de exame médico-oftalmológico.