The purpose of the present study was to translate the Roland-Morris (RM) questionnaire into Brazilian-Portuguese and adapt and validate it. First 3 English teachers independently translated the original questionnaire into Brazilian-Portuguese and a consensus version was generated. Later, 3 other translators, blind to the original questionnaire, performed a back translation. This version was then compared with the original English questionnaire. Discrepancies were discussed and solved by a panel of 3 rheumatologists and the final Brazilian version was established (Brazil-RM). This version was then pretested on 30 chronic low back pain patients consecutively selected from the spine disorders outpatient clinic. In addition to the traditional clinical outcome measures, the Brazil-RM, a 6-point pain scale (from no pain to unbearable pain), and its numerical pain rating scale (PS) (0 to 5) and a visual analog scale (VAS) (0 to 10) were administered twice by one interviewer (1 week apart) and once by one independent interviewer. Spearman's correlation coefficient (SCC) and intraclass correlation coefficient (ICC) were computed to assess test-retest and interobserver reliability. Cross-sectional construct validity was evaluated using the SCC. In the pretesting session, all questions were well understood by the patients. The mean time of questionnaire administration was 4 min and 53 s. The SCC and ICC were 0.88 (P<0.01) and 0.94, respectively, for the test-retest reliability and 0.86 (P<0.01) and 0.95, respectively, for interobserver reliability. The correlation coefficient was 0.80 (P<0.01) between the PS and Brazil-RM score and 0.79 (P<0.01) between the VAS and Brazil-RM score. We conclude that the Brazil-RM was successfully translated and adapted for application to Brazilian patients, with satisfactory reliability and cross-sectional construct validity.
Resumo:
OBJECTIVE: The increasing proportion of older adults in the general population and the specific characteristics of this age group show the need for the development of specific instruments to measure quality of life in older adults. The study aimed at describing the development and validation of the Portuguese version of the World Health Organization Quality of Life for Older Persons (WHOQOL-OLD) module. METHODS: The WHOQOL-OLD instrument was administered in a sample of 424 older adults in the city of Porto Alegre, Southern Brazil, in 2005. The questionnaire comprises 24 items divided into six facets: sensory abilities; autonomy; past, present and future activities; social participation; death and dying; and intimacy. Besides the WHOQOL-OLD module, the WHOQOL-BREF, BDI and BHS instruments were also applied. The instrument's internal consistency was assessed using Cronbach's alpha coefficient. RESULTS: The instrument showed adequate internal consistency (Cronbach's coefficients ranging from 0.71 to 0.88), discriminant validity (p<0.01), concurrent validity (correlation coefficients ranging from -0.61 to -0.50) and test-retest reliability (correlation coefficients ranging from 0.58 to 0.82). Findings concerning criterion validity need further studies. CONCLUSIONS: The WHOQOL-Old module is a useful alternative with good psychometric performance in the investigation of quality of life in older adults.
Resumo:
OBJECTIVE Translate the Patient-centered Assessment and Counseling for Exercise questionnaire, adapt it cross-culturally and identify the psychometric properties of the psychosocial scales for physical activity in young university students.METHODS The Patient-centered Assessment and Counseling for Exercise questionnaire is made up of 39 items divided into constructs based on the social cognitive theory and the transtheoretical model. The analyzed constructs were, as follows: behavior change strategy (15 items), decision-making process (10), self-efficacy (6), support from family (4), and support from friends (4). The validation procedures were conceptual, semantic, operational, and functional equivalences, in addition to the equivalence of the items and of measurements. The conceptual, of items and semantic equivalences were performed by a specialized committee. During measurement equivalence, the instrument was applied to 717 university students. Exploratory factor analysis was used to verify the loading of each item, explained variance and internal consistency of the constructs. Reproducibility was measured by means of intraclass correlation coefficient.RESULTS The two translations were equivalent and back-translation was similar to the original version, with few adaptations. The layout, presentation order of the constructs and items from the original version were kept in the same form as the original instrument. The sample size was adequate and was evaluated by the Kaiser-Meyer-Olkin test, with values between 0.72 and 0.91. The correlation matrix of the items presented r < 0.8 (p < 0.05). The factor loadings of the items from all the constructs were satisfactory (> 0.40), varying between 0.43 and 0.80, which explained between 45.4% and 59.0% of the variance. Internal consistency was satisfactory (α ≥ 0.70), with support from friends being 0.70 and 0.92 for self-efficacy. Most items (74.3%) presented values above 0.70 for the reproducibility test.CONCLUSIONS The validation process steps were considered satisfactory and adequate for applying to the population.
Resumo:
ABSTRACT OBJECTIVE To validate an instrument designed to assess health promotion in the school environment. METHODS A questionnaire, based on guidelines from the World Health Organization and in line with the Brazilian school health context, was developed to validate the research instrument. There were 60 items in the instrument that included 40 questions for the school manager and 20 items with direct observations made by the interviewer. The items’ content validation was performed using the Delphi technique, with the instrument being applied in 53 schools from two medium-sized cities in the South region of Brazil. Reliability (Cronbach’s alpha and split-half) and validity (principal component analysis) analyses were performed. RESULTS The final instrument remained composed of 28 items, distributed into three dimensions: pedagogical, structural and relational. The resulting components showed good factorial loads (> 0.4) and acceptable reliability (> 0.6) for most items. The pedagogical dimension identifies educational activities regarding drugs and sexuality, violence and prejudice, auto care and peace and quality of life. The structural dimension is comprised of access, sanitary structure, and conservation and equipment. The relational dimension includes relationships within the school and with the community. CONCLUSIONS The proposed instrument presents satisfactory validity and reliability values, which include aspects relevant to promote health in schools. Its use allows the description of the health promotion conditions to which students from each educational institution are exposed. Because this instrument includes items directly observed by the investigator, it should only be used during periods when there are full and regular activities at the school in question.
Resumo:
The aim of this study was to validate the 14C-urea breath test for use in diagnosis of Helicobacter pylori infection. Thirty H. pylori positive patients, based on histologic test and thirty H. pylori negative patients by histology and anti-H. pylori IgG entered the study. Fasting patients drank 5 uCi of 14C-urea in 20 ml of water. Breath samples were collected at 0, 5, 10, 15, 20 and 30 min. The difference of cpm values between the two groups was significant at all the time intervals, besides time 0 (p<0.0001). At 20 min, the test gave 100% sensitivity and specificity with a cut-off value of 562 cpm. Females were higher expirers than males (p=0.005). 14C-urea breath test is highly accurate for Helicobacter pylori diagnosis. It is fast, simple and should be the non-invasive test used after treating Helicobacter pylori infection.
Resumo:
The aim of this study was to validate the rapid lateral flow Helicobacter pylori stool antigen test (One step H. pylori antigen test, ACON laboratories, San Diego, USA; Prime diagnostics, São Paulo), using 13C-Urea Breath Test as the gold standard for H. pylori infection diagnosis. A total of 98 consecutive patients, asymptomatic or dyspeptic, entered the study. Sixty-nine were women, with a mean age of 45.76 ± 14.59 years (14 to 79 years). In the H. pylori-positive group, the rapid stool antigen test detected H. pylori antigen in 44 of the 50 positive patients (sensitivity 88%; 95% CI: 75.7-95.5%), and six false-negative; and in the H. pylori-negative group 42 presented negative results (specificity 87.5%; 95% CI: 74.7-95.3%), and six false-positive, showing a substantial agreement (Kappa Index = 0.75; p < 0.0001; 95% CI: 0.6-0.9). Forty four of fifty patients that had positive stool antigen were H. pylori-positive, the PPV of the stool antigen test was 88% (95% CI: 75.7-95.5%), and 42 patients with negative stool antigen test were H. pylori-negative, the NPV of the stool antigen test was 87.5% (95% CI: 74.7-95.3%). We conclude that the lateral flow stool antigen test can be used as an alternative to breath test for H. pylori infection diagnosis especially in developing countries.
Resumo:
INTRODUCTION: Leptospirosis is often mistaken for other acute febrile illnesses because of its nonspecific presentation. Bacteriologic, serologic, and molecular methods have several limitations for early diagnosis: technical complexity, low availability, low sensitivity in early disease, or high cost. This study aimed to validate a case definition, based on simple clinical and laboratory tests, that is intended for bedside diagnosis of leptospirosis among hospitalized patients. METHODS: Adult patients, admitted to two reference hospitals in Recife, Brazil, with a febrile illness of less than 21 days and with a clinical suspicion of leptospirosis, were included to test a case definition comprising ten clinical and laboratory criteria. Leptospirosis was confirmed or excluded by a composite reference standard (microscopic agglutination test, ELISA, and blood culture). Test properties were determined for each cutoff number of the criteria from the case definition. RESULTS: Ninety seven patients were included; 75 had confirmed leptospirosis and 22 did not. Mean number of criteria from the case definition that were fulfilled was 7.8±1.2 for confirmed leptospirosis and 5.9±1.5 for non-leptospirosis patients (p<0.0001). Best sensitivity (85.3%) and specificity (68.2%) combination was found with a cutoff of 7 or more criteria, reaching positive and negative predictive values of 90.1% and 57.7%, respectively; accuracy was 81.4%. CONCLUSIONS: The case definition, for a cutoff of at least 7 criteria, reached average sensitivity and specificity, but with a high positive predictive value. Its simplicity and low cost make it useful for rapid bedside leptospirosis diagnosis in Brazilian hospitalized patients with acute severe febrile disease.
Resumo:
ABSTRACT Objective To perform the psychometric evaluation of the Disordered Eating Attitude Scale (DEAS) for adolescents. Methods Sample consisted of 1,119 Brazilian adolescents (12-18 years old; 59.6% female) studying at technical schools in São Paulo state-Brazil, who answered an online survey with the DEAS, the Eating Attitude Test (EAT-26), and the Restraint Scale (RS). The internal consistency of the DEAS was assessed using Cronbach’s alpha. The convergent validity of DEAS was evaluated by means of Pearson’s coefficient correlation with EAT-26 and RS. The test-retest reliability was evaluated using a sub-sample of 61 adolescents. Known-groups validity was determined by comparing female student mean scores with scores of 33 female adolescents with eating disorders. Results The reliability of the DEAS was 0.79. EAT-26 and RS scores were positively correlated with DEAS scores (EAT: 0.78 for females and 0.59 for males, p < 0.001; RS: 0.63 for females and 0.48 for males, p < 0.001). The DEAS total and subscale scores differentiated students and patients with eating disorders (p < 0.001). The intra-class correlation coefficient for test-retest reliability was 0.87. Conclusion Results indicate that the DEAS adolescent version showed good internal consistency, convergent validity, known-groups validity, and test-retest reliability, suggesting its potential in identifying disordered eating attitudes among adolescents. It could also be helpful in identifying adolescents at risk from eating disorders, assisting in prevention programs.
Validation of the Killip-Kimball Classification and Late Mortality after Acute Myocardial Infarction
Resumo:
Background: The classification or index of heart failure severity in patients with acute myocardial infarction (AMI) was proposed by Killip and Kimball aiming at assessing the risk of in-hospital death and the potential benefit of specific management of care provided in Coronary Care Units (CCU) during the decade of 60. Objective: To validate the risk stratification of Killip classification in the long-term mortality and compare the prognostic value in patients with non-ST-segment elevation MI (NSTEMI) relative to patients with ST-segment elevation MI (STEMI), in the era of reperfusion and modern antithrombotic therapies. Methods: We evaluated 1906 patients with documented AMI and admitted to the CCU, from 1995 to 2011, with a mean follow-up of 05 years to assess total mortality. Kaplan-Meier (KM) curves were developed for comparison between survival distributions according to Killip class and NSTEMI versus STEMI. Cox proportional regression models were developed to determine the independent association between Killip class and mortality, with sensitivity analyses based on type of AMI. Results: The proportions of deaths and the KM survival distributions were significantly different across Killip class >1 (p <0.001) and with a similar pattern between patients with NSTEMI and STEMI. Cox models identified the Killip classification as a significant, sustained, consistent predictor and independent of relevant covariables (Wald χ2 16.5 [p = 0.001], NSTEMI) and (Wald χ2 11.9 [p = 0.008], STEMI). Conclusion: The Killip and Kimball classification performs relevant prognostic role in mortality at mean follow-up of 05 years post-AMI, with a similar pattern between NSTEMI and STEMI patients.
Resumo:
AbstractBackground:30-40% of cardiac resynchronization therapy cases do not achieve favorable outcomes.Objective:This study aimed to develop predictive models for the combined endpoint of cardiac death and transplantation (Tx) at different stages of cardiac resynchronization therapy (CRT).Methods:Prospective observational study of 116 patients aged 64.8 ± 11.1 years, 68.1% of whom had functional class (FC) III and 31.9% had ambulatory class IV. Clinical, electrocardiographic and echocardiographic variables were assessed by using Cox regression and Kaplan-Meier curves.Results:The cardiac mortality/Tx rate was 16.3% during the follow-up period of 34.0 ± 17.9 months. Prior to implantation, right ventricular dysfunction (RVD), ejection fraction < 25% and use of high doses of diuretics (HDD) increased the risk of cardiac death and Tx by 3.9-, 4.8-, and 5.9-fold, respectively. In the first year after CRT, RVD, HDD and hospitalization due to congestive heart failure increased the risk of death at hazard ratios of 3.5, 5.3, and 12.5, respectively. In the second year after CRT, RVD and FC III/IV were significant risk factors of mortality in the multivariate Cox model. The accuracy rates of the models were 84.6% at preimplantation, 93% in the first year after CRT, and 90.5% in the second year after CRT. The models were validated by bootstrapping.Conclusion:We developed predictive models of cardiac death and Tx at different stages of CRT based on the analysis of simple and easily obtainable clinical and echocardiographic variables. The models showed good accuracy and adjustment, were validated internally, and are useful in the selection, monitoring and counseling of patients indicated for CRT.
Resumo:
Abstract Background: The Walking Estimated-Limitation Calculated by History (WELCH) questionnaire has been proposed to evaluate walking impairment in patients with intermittent claudication (IC), presenting satisfactory psychometric properties. However, a Brazilian Portuguese version of the questionnaire is unavailable, limiting its application in Brazilian patients. Objective: To analyze the psychometric properties of a translated Brazilian Portuguese version of the WELCH in Brazilian patients with IC. Methods: Eighty-four patients with IC participated in the study. After translation and back-translation, carried out by two independent translators, the concurrent validity of the WELCH was analyzed by correlating the questionnaire scores with the walking capacity assessed with the Gardner treadmill test. To determine the reliability of the WELCH, internal consistency and test–retest reliability with a seven-day interval between the two questionnaire applications were calculated. Results: There were significant correlations between the WELCH score and the claudication onset distance (r = 0.64, p = 0.01) and total walking distance (r = 0.61, p = 0.01). The internal consistency was 0.84 and the intraclass correlation coefficient between questionnaire evaluations was 0.84. There were no differences in WELCH scores between the two questionnaire applications. Conclusion: The Brazilian Portuguese version of the WELCH presents adequate validity and reliability indicators, which support its application to Brazilian patients with IC.
Resumo:
The performance of the immunochromatographic assay, SD BIOLINE TB Ag MPT64 RAPID®, was evaluated in Madagascar. Using mouse anti-MPT64 monoclonal antibodies for rapid discrimination between the Mycobacterium tuberculosis complex and nontuberculous mycobacteria, the kit was tested on mycobacteria and other pathogens using conventional methods as the gold standard. The results presented here indicate that this kit has excellent sensitivity (100%) and specificity (100%) compared to standard biochemical detection and can be easily used for the rapid identification of M. tuberculosis complex.
Resumo:
A fluorimetric microassay that uses a redox dye to determine the viability of the flagellate Trichomonas vaginalis has been optimised to provide a more sensitive method to evaluate potential trichomonacidal compounds. Resazurin has been used in recent years to test drugs against different parasites, including trichomonadid protozoa; however, the reproducibility of these resazurin-based methods in our laboratory has been limited because the flagellate culture medium spontaneously reduces the resazurin. The objective of this work was to refine the fluorimetric microassay method previously developed by other research groups to reduce the fluorescence background generated by the media and increase the sensitivity of the screening assay. The experimental conditions, time of incubation, resazurin concentration and media used in the microtitre plates were adjusted. Different drug sensitivity studies against T. vaginalis were developed using the 5-nitroimidazole reference drugs, new 5-nitroindazolinones and 5-nitroindazole synthetic derivatives. Haemocytometer count results were compared with the resazurin assay using a 10% solution of 3 mM resazurin dissolved in phosphate buffered saline with glucose (1 mg/mL). The fluorimetric assay and the haemocytometer counts resulted in similar percentages of trichomonacidal activity in all the experiments, demonstrating that the fluorimetric microtitre assay has the necessary accuracy for high-throughput screening of new drugs against T. vaginalis.
Resumo:
In this study, PCR assays targeting different Leishmania heat-shock protein 70 gene (hsp70) regions, producing fragments ranging in size from 230-390 bp were developed and evaluated to determine their potential as a tool for the specific molecular diagnosis of cutaneous leishmaniasis (CL). A total of 70 Leishmania strains were analysed, including seven reference strains (RS) and 63 previously typed strains. Analysis of the RS indicated a specific region of 234 bp in the hsp70 gene as a valid target that was highly sensitive for detection of Leishmania species DNA with capacity of distinguishing all analyzed species, after polymerase chain reaction-restriction fragment length polymorfism (PCR-RFLP). This PCR assay was compared with other PCR targets used for the molecular diagnosis of leishmaniasis: hsp70 (1400-bp region), internal transcribed spacer (ITS)1 and glucose-6-phosphate dehydrogenase (G6pd). A good agreement among the methods was observed concerning the Leishmania species identification. Moreover, to evaluate the potential for molecular diagnosis, we compared the PCR targets hsp70-234 bp, ITS1, G6pd and mkDNA using a panel of 99 DNA samples from tissue fragments collected from patients with confirmed CL. Both PCR-hsp70-234 bp and PCR-ITS1 detected Leishmania DNA in more than 70% of the samples. However, using hsp70-234 bp PCR-RFLP, identification of all of the Leishmania species associated with CL in Brazil can be achieved employing a simpler and cheaper electrophoresis protocol.