113 resultados para Unsteady flow (Aerodynamics)

em Scielo Saúde Pública - SP


Relevância:

90.00% 90.00%

Publicador:

Resumo:

An experimental study was conducted in a pump-turbine model in pumping mode, in order to characterize the flow field structure in the region between stay and guide vanes, using mainly the laser-Doppler anemometry in a two-color and back-scattered light-based system. The structure of the steady and unsteady flow was analyzed. The measurements were performed at three operation points. The obtained data provide appropriate boundary conditions and a good base of validation for numerical codes, and for the understanding of main loss mechanisms of this complex flow.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The unsteady, viscous, supersonic flow over a spike-nosed body of revolution is numerically investigated by solving the Navier-Stokes equations. The time-accurate computations are performed employing an implicit algorithm based on the second-order time-accurate LU-SGS scheme with the incorporation of a subiteration procedure to maintain time accuracy. The characteristics of the flow field for a Mach number of 3.0, Reynolds number of 7.87 x 10(6)/m, and angles of attack of 5 and 10 degrees are described. Self-sustained asymmetric shock wave oscillations were observed in the numerical computations for these angles of attack. The main characteristic of the flow field, as well as its influence on drag coefficient is discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The mathematical model for two-dimensional unsteady sonic flow, based on the classical diffusion equation with imaginary coefficient, is presented and discussed. The main purpose is to develop a rigorous formulation in order to bring into light the correspondence between the sonic, supersonic and subsonic panel method theory. Source and doublet integrals are obtained and Laplace transformation demonstrates that, in fact, the source integral is the solution of the doublet integral equation. It is shown that the doublet-only formulation reduces to a Volterra integral equation of the first kind and a numerical method is proposed in order to solve it. To the authors' knowledge this is the first reported solution to the unsteady sonic thin airfoil problem through the use of doublet singularities. Comparisons with the source-only formulation are shown for the problem of a flat plate in combined harmonic heaving and pitching motion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Non-linear functional representation of the aerodynamic response provides a convenient mathematical model for motion-induced unsteady transonic aerodynamic loads response, that accounts for both complex non-linearities and time-history effects. A recent development, based on functional approximation theory, has established a novel functional form; namely, the multi-layer functional. For a large class of non-linear dynamic systems, such multi-layer functional representations can be realised via finite impulse response (FIR) neural networks. Identification of an appropriate FIR neural network model is facilitated by means of a supervised training process in which a limited sample of system input-output data sets is presented to the temporal neural network. The present work describes a procedure for the systematic identification of parameterised neural network models of motion-induced unsteady transonic aerodynamic loads response. The training process is based on a conventional genetic algorithm to optimise the network architecture, combined with a simplified random search algorithm to update weight and bias values. Application of the scheme to representative transonic aerodynamic loads response data for a bidimensional airfoil executing finite-amplitude motion in transonic flow is used to demonstrate the feasibility of the approach. The approach is shown to furnish a satisfactory generalisation property to different motion histories over a range of Mach numbers in the transonic regime.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To describe the migration flows of demand for public and private hospital care among the health regions of the state of Sao Paulo, Brazil. METHODS Study based on a database of hospitalizations in the public and private systems of the state of Sao Paulo, Southeastern Brazil, in 2006. We analyzed data from 17 health regions of the state, considering people hospitalized in their own health region and those who migrated outwards (emigration) or came from other regions (immigration). The index of migration effectiveness of patients from both systems was estimated. The coverage (hospitalization coefficient) was analyzed in relation to the number of inpatient beds per population and the indexes of migration effectiveness. RESULTS The index of migration effectiveness applied to the hospital care demand flow allowed characterizing health regions with flow balance, with high emigration of public and private patients, and with high attraction of public and private patients. CONCLUSIONS There are differences in hospital care access and opportunities among health regions in the state of Sao Paulo, Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARYAIDS-related cryptococcal meningitis continues to cause a substantial burden of death in low and middle income countries. The diagnostic use for detection of cryptococcal capsular polysaccharide antigen (CrAg) in serum and cerebrospinal fluid by latex agglutination test (CrAg-latex) or enzyme-linked immunoassay (EIA) has been available for over decades. Better diagnostics in asymptomatic and symptomatic phases of cryptococcosis are key components to reduce mortality. Recently, the cryptococcal antigen lateral flow assay (CrAg LFA) was included in the armamentarium for diagnosis. Unlike the other tests, the CrAg LFA is a dipstick immunochromatographic assay, in a format similar to the home pregnancy test, and requires little or no lab infrastructure. This test meets all of the World Health Organization ASSURED criteria (Affordable, Sensitive, Specific, User friendly, Rapid/robust, Equipment-free, and Delivered). CrAg LFA in serum, plasma, whole blood, or cerebrospinal fluid is useful for the diagnosis of disease caused by Cryptococcusspecies. The CrAg LFA has better analytical sensitivity for C. gattii than CrAg-latex or EIA. Prevention of cryptococcal disease is new application of CrAg LFA via screening of blood for subclinical infection in asymptomatic HIV-infected persons with CD4 counts < 100 cells/mL who are not receiving effective antiretroviral therapy. CrAg screening of leftover plasma specimens after CD4 testing can identify persons with asymptomatic infection who urgently require pre-emptive fluconazole, who will otherwise progress to symptomatic infection and/or die.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a rapid method for the flow cytometric quantitation of phagocytosis in heparinized complete peripherial blood (HCPB), using commercially available phycoerythrin-conjugated latex particles of 1µm diameter. The method is faster and shows greater reproducibility than Bjerknes' (1984) standard technique using propidium iodide-stained Candida albicans, conventionally applied to the leukocytic layer of peripherial blood but here modified for HCPB. We also report a modification of Bjerknes' Intracellular Killing Test to allow its application to HCPB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mycobaterium leprae infection was investigated in armadillos from the State of Espírito Santo, Brazil. The ML Flow test was performed on 37 nine-banded armadillos and positive results were found in 11 (29.7%). The ML Flow test may be used to identify possible sources of Mycobaterium leprae among wild armadillos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O ML Flow e o ELISA PGL-I são testes sorológicos que detectam anticorpos IgM contra o glicolipídio fenólico I específico do Mycobacterium leprae. Para avaliar o comportamento destes testes em áreas endêmica e não endêmica para hanseníase foram estudados 351 voluntários no Brasil e no Chile, incluindo pacientes com hanseníase, controles sadios, portadores de outras doenças infecciosas, não infecciosas e dermatoses que fazem diagnóstico diferencial com hanseníase. O ponto de corte do ELISA foi estabelecido pelo método da Curva ROC (> 0,157). Em área endêmica, o ML Flow apresentou resultados positivos em 70% dos pacientes com hanseníase; o ELISA foi positivo em 53,3%. Em área não endêmica, o ML Flow foi negativo em todos os voluntários testados; o ELISA foi positivo em 4 voluntários. O ML Flow é um ensaio mais rápido, facilmente aplicável e, portanto, mais adequado para ser utilizado na Atenção Básica; o ELISA necessita, alem de uma infra-estrutura de laboratório adequada, pessoal treinado e especializado em sua execução.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Realizou-se estudo descritivo e exploratório relacionando as covariáveis aos resultados do teste sorológico ML Flow e baciloscopia. Foram estudados 60 casos novos de hanseníase diagnosticados no Centro de Referência em Dermatologia Sanitária. Para a baciloscopia, foi utilizada a coleta de esfregaço dérmico em quatro sítios, sendo o resultado expresso pelo índice bacilocópico. O ML Flow foi registrado de modo qualitativo e semi-quantitativo. Para o estudo da concordância, foi utilizado o índice de Kappa e, para sua interpretação, os critérios de Landis e Koch. Para análise estatística foram realizados a regressão logística e o teste de Kruskal-Wallis. O ML Flow mostrou forte associação com a baciloscopia, observou-se que o aumento gradativo do índice baciloscópico foi acompanhado pelo aumento semi-quantitativo dos níveis de anticorpos medidos pelo ML Flow, tendo sido positivo em 100% dos casos com baciloscopia positiva. Os resultados deste estudo evidenciaram que o ML Flow, por estar fortemente correlacionado à bacilocopia, poderá tornar-se um valioso instrumento auxiliar na classificação e alocação dos pacientes para fins de tratamento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudo descritivo e exploratório correlacionando o ML Flow, a baciloscopia e a classificação em paucibacilar (PB) e multibacilar (MB), envolveu 1.041 casos novos com hanseníase em 13 municípios de Minas Gerais, de outubro de 2002 a março de 2004. A concordância entre o ML Flow e a classificação pelo número de lesões cutâneas e a baciloscopia foi moderada (Kappa:0,51 e 0,48, respectivamente) e, substancial (Kappa:0,77) com a classificação final. De janeiro de 2000 a março de 2004, a proporção de casos novos MB no Estado, passou de 78,1 para 65,8%. A queda no percentual de MB foi maior nos serviços participantes da pesquisa ML Flow (73,1 para 53,3%). A diferença de PB e MB nos serviços participantes e não participantes, de janeiro a março de 2004, foi estatisticamente significativa, indicando implicação direta e benéfica no tratamento e no controle da endemia em Minas Gerais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O diagnóstico precoce da hanseníase, a correta classificação e o estudo dos fatores de risco relacionados à soropositividade, tornam-se importantes para o tratamento do doente e controle da endemia, especialmente, quando a responsabilidade pelo atendimento desses pacientes está sendo absorvida pelos serviços de atenção básica. Estudo descritivo e exploratório utilizando regressão logística avaliou a associação das variáveis: sexo, idade, modo de detecção, número de lesões cutâneas e de nervos acometidos, grau de incapacidade, baciloscopia, com o resultado do teste sorológico ML Flow, em 1.072 casos novos com hanseníase em 13 municípios de Minas Gerais. A soropositividade (50,7%) estava estatisticamente associada aos pacientes com 15 anos ou mais de idade (OR:2,6), mais de cinco lesões cutâneas (OR:7,5), mais de um nervo acometido (OR:2,4) e com baciloscopia positiva (OR:5,5 para IB<2 e OR:191,2 para IB>2), colaborando, assim, com a classificação e o tratamento adequados dos doentes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A hanseníase ainda é doença endêmica no Brasil, com cerca de 40.000 novos casos por ano. Devido à dificuldade na realização de exames laboratoriais em campo, classifica-se a forma clínica contando-se lesões, o que pode causar subdiagnóstico de casos multibacilares e falha terapêutica. Para avaliar uma nova ferramenta para diagnóstico de hanseníase multibacilar, o teste ML Flow, foi realizado em 21/77 (27,3%) pacientes com hanseníase dimorfa (6 DV e 15 DT) não tratados, com até cinco lesões de pele, avaliados de acordo com a classificação de Ridley & Jopling (R&J). O teste ML Flow foi positivo em 14/21 (66,6%) pacientes (4 DV e 10 DT); em 7/21 (33,3%) pacientes (5 DT e 2 DV) o resultado foi negativo. A classificação da hanseníase baseada somente na contagem de lesões pode falhar em diagnosticar casos MB. O ML Flow é ferramenta útil no diagnóstico de hanseníase dimorfa com até cinco lesões cutâneas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A hanseníase é um problema de saúde pública no Brasil. As ações de controle estão baseadas no diagnóstico e tratamento dos indivíduos doentes e na vigilância de seus contatos. Os testes sorológicos permitem identificar, entre os contatos, aqueles com maior risco de desenvolver hanseníase. O ML Flow foi utilizado em 2.840 contatos intradomiciliares de casos novos de hanseníase, diagnosticados entre outubro de 2002 e março de 2004, em Minas Gerais. O ML Flow foi positivo em 20,5% dos contatos de hanseníase, sendo maior nos contatos do sexo masculino (22,4%), nos maiores de 15 anos (21,7%), nos contatos de doentes multibacilares (23,9%). A chance de um contato ser soropositivo foi maior se convivia com caso multibacilar (OR=1,75), idade superior a 15 anos (OR=1,38) e sexo masculino (OR=1,25). O acompanhamento desses contatos permitirá, no futuro, avaliar o risco que a soropositividade representa no desenvolvimento de hanseníase.