48 resultados para Ultrasonic Transducer

em Scielo Saúde Pública - SP


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ultrasonic attenuation coefficient, wave propagation speed and integrated backscatter coefficient (IBC) of human coronary arteries were measured in vitro over the -6 dB frequency bandwidth (36 to 67 MHz) of a focused ultrasound transducer (50 MHz, focal distance 5.7 mm, f/number 1.7). Corrections were made for diffraction effects. Normal and diseased coronary artery sub-samples (N = 38) were obtained from 10 individuals at autopsy. The measured mean ± SD of the wave speed (average over the entire vessel wall thickness) was 1581.04 ± 53.88 m/s. At 50 MHz, the average attenuation coefficient was 4.99 ± 1.33 dB/mm with a frequency dependence term of 1.55 ± 0.18 determined over the 36- to 67-MHz frequency range. The IBC values were: 17.42 ± 13.02 (sr.m)-1 for thickened intima, 11.35 ± 6.54 (sr.m)-1 for fibrotic intima, 39.93 ± 50.95 (sr.m)-1 for plaque, 4.26 ± 2.34 (sr.m)-1 for foam cells, 5.12 ± 5.85 (sr.m)-1 for media and 21.26 ± 31.77 (sr.m)-1 for adventitia layers. The IBC results indicate the possibility for ultrasound characterization of human coronary artery wall tissue layer, including the situations of diseased arteries with the presence of thickened intima, fibrotic intima and plaque. The mean IBC normalized with respect to the mean IBC of the media layer seems promising for use as a parameter to differentiate a plaque or a thickened intima from a fibrotic intima.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spray-drying technique has been widely used for drying heat-sensitive foods, pharmaceuticals, and other substances, because it leads to rapid solvent evaporation from droplets. This method involves the transformation of a feed from a fluid state into a dried particulate, by spraying the feed into a hot medium. Despite being most often considered a dehydration process, spray drying can also be used as an encapsulation method. Therefore, this work proposes the use of a simple and low-cost ultrasonic spray dryer system to produce spherical microparticles. This equipment was successfully applied to the preparation of dextrin microspheres on a laboratory scale and for academic purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MgO is an important inorganic material, which can be used in many aspects, such as catalyst, toxic-waste remediation agent, adsorbent, and others. In order to make use of MgO, nano-MgO was prepared by ultrasonic method using Mg (CH3COO)2.2H2O as precursor, NaOH aqueous solution as precipitant in this paper. Effect factors on MgO nano-particle size were investigated. Characteristics of samples were measured by TGA, XRD, TEM, and others techniques. The results showed that the size of nano-MgO about 4 nm could be obtained under the following conditions (ultrasonic time 20 min, ultrasonic power 250 W, titration rate of NaOH 0.25 mL/min, NaOH concentration 0.48 mol/L, calcinations temperature 410 °C, calcination time 1.5 h, heating rate of calcination 5 °C/min). It was a very simple and effective method to prepare nano-MgO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the modulus tangent (Eci ) and of the modulus secant (Ecs) of the concrete can be done using compression test but, to be simpler, it is used relations with characteristic strength (f ck). Relations are also used to determine the transversal modulus (Gc) and, in the case of the Poisson's ratio (ν), a fixed value 0.20 is established. The objective of this research was to evaluate the use of the ultrasonic propagation waves to determine these properties. For the tests were used specimens with f ck varying from 10 to 35 MPa. For the ultrasonic tests were used cylindrical and cubic specimens. The modulus of deformation obtained by ultrasound was statistically equivalent to the obtained by compression tests. The results of modules obtained using the relations with f ck was far away from those obtained by ultrasound or by compression tests. The Poisson's ratio obtained by ultrasound was superior to the fixed value. We can conclude that the concrete characterization by ultrasound is consistent and, to this characterization the cylindrical specimen, normally used to determine f ck, can be used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an electronic transducer for multiphase flow measurement. Its high sensitivity, good signal to noise ratio and accuracy are achieved through an electrical impedance sensor with a special guard technique. The transducer consists of a wide bandwidth and high slew rate differentiator where the lead inductance and stray capacitance effects are compensated. The sensor edge effect is eliminated by using a guard electrode based on the virtual ground potential of the operational amplifier. A theoretical modeling and a calibration method are also presented. The results obtained seem to confirm the validity of the proposed technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present review, the phenomenon of ultrasonic vocalization in rats will be outlined, including the three classes of vocalizations, namely 40-kHz calls of pups, and 22- and 50-kHz calls of juvenile and adult rats, their general relevance to behavioral neuroscience, and their special relevance to research on anxiety, fear, and defense mechanisms. Here, the emphasis will be placed on 40- and 22-kHz calls, since they are typical for various situations with aversive properties. Among other topics, we will discuss whether such behavioral signals can index a certain affective state, and how these signals can be used in social neuroscience, especially with respect to communication. Furthermore, we will address the phenomenon of inter-individual variability in ultrasonic calling and what we currently know about the mechanisms, which may determine such variability. Finally, we will address the current knowledge on the neural and pharmacological mechanisms underlying 22-kHz ultrasonic vocalization, which show a substantial overlap with mechanisms known from other research on fear and anxiety, such as those involving the periaqueductal gray or the amygdala.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate echocardiography accuracy in performing and obtaining images for dynamical three-dimensional (3D) reconstruction. METHODS: Three-dimensional (3D) image reconstruction was obtained in 20 consecutive patients who underwent transesophageal echocardiography. A multiplanar 5 MHz transducer was used for 3D reconstruction. RESULTS: Twenty patients were studied consecutively. The following cardiac diseases were present: valvar prostheses-6 (2 mitral, 2 aortic and 2 mitral and aortic); mitral valve prolapse- 3; mitral and aortic disease - 2; aortic valve disease- 5; congenital heart disease- 3 (2 atrial septal defect- ASD - and 1 transposition of the great arteries -TGA); arteriovenous fistula- 1. In 7 patients, color Doppler was also obtained and used for 3D flow reconstruction. Twenty five cardiac structures were acquired and 60 reconstructions generated (28 of mitral valves, 14 of aortic valves, 4 of mitral prostheses, 7 of aortic prostheses and 7 of the ASD). Fifty five of 60 (91.6%) reconstructions were considered of good quality by 2 independent observers. The 11 reconstructed mitral valves/prostheses and the 2 reconstructed ASDs provided more anatomical information than two dimensional echocardiography (2DE) alone. CONCLUSION: 3D echocardiography using a transesophageal transducer is a feasible technique, which improves detection of anatomical details of cardiac structures, particularly of the mitral valve and atrial septum.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pineal gland functions as a neuroendocrine transducer that coordinate the organism response to changing environmental stimuli such as light and temperature. The main and best known pineal neurohormone is melatonin that is synthesized and released in a circadian fashion with a peak during the night darkness hours. We have recently reported that melatonin exerts important immuno regulatory functions. Here we describe the astonishing property of exogenous melatonin which is able to counteract completely the depressive effect of anxiety-restraint stress and/or of corticosterone on thymus weight, andibody production and antiviral responses. This effect seems to be mediated by antigen-activated T cells via an opiatergic mechanism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bradykinin (BK) a nonapeptide generated in plasma during tissue injury, is involved in many physiological and pathological states. Kinin actions are mediated by specific membrane receptors and involve a complex signal transducer and also second messager mechanisms. Due to its inequivocal relevance, an intensive effort has been focused in recent years to develop selective and competitive BK antagonists. Thus, the development of a new series of peptide BK antagonists has made an important contribution to the understanding of the pharmacological, physiological and pathophysiological role of BK, and this is certain to provide a firm basis for developing new drugs to relieve pain and inflammation. However, BK antagonists derived from peptide origin reported to date have limited clinical use due to their poor oral absortion and short duration of effect. Thus, considerable effort has also been made in developing stable nonpeptide BK antagonists. Up to now, most nonpeptide compounds reported to exhibit BK antagonistic activity have been derived from plants, including many flavonoids, terpenes, and also synthetic substances with various molecular structures. Amongst them, the pregnane glycoside compounds isolated from the plant Mandevilla velutina are the most promising. These compounds are effective in antognizing BK responses in a variety of preparations, and they also exhibit potent and long-lasting analgesic and anti-inflammatory activities. The exact mechanism underlying their action however, is not yet completely understood.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Parasites remain competent invaders of host immunity. Their invasion strategies have proven to impact immunorelevant genes leading to diversity among gene families. We focussed on signal transducer and activator of transcription (STAT6) factor that plays a fundamental role in signal transduction and activation of transcription. Recent studies have highlighted the role of STAT6 variants in control of infection levels. We identified and investigated regulatory single nucleotide polymorphisms (SNPs) in the promoter regions of the STAT6 gene in a group of Gabonese individuals exposed to a variety of parasitic infections. Three promoter variants were identified in 40 individual subjects. We further validated these promoter variants for their allelic gene expression using transient transfection assays. One promoter variant, rs3024944 (G/C), revealed an altered expression of the marker gene. The identification of function-altering SNPs in the promoter may facilitate studying parasite susceptibility in association studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To evaluate the sonographic measurement of subcutaneous and visceral fat in correlation with the grade of hepatic steatosis. Materials and Methods In the period from October 2012 to January 2013, 365 patients were evaluated. The subcutaneous and visceral fat thicknesses were measured with a convex, 3–4 MHz transducer transversely placed 1 cm above the umbilical scar. The distance between the internal aspect of the abdominal rectus muscle and the posterior aortic wall in the abdominal midline was considered for measurement of the visceral fat. Increased liver echogenicity, blurring of vascular margins and increased acoustic attenuation were the parameters considered in the quantification of hepatic steatosis. Results Steatosis was found in 38% of the study sample. In the detection of moderate to severe steatosis, the area under the ROC curve was 0.96 for women and 0.99 for men, indicating cut-off values for visceral fat thickness of 9 cm and 10 cm, respectively. Conclusion The present study evidenced the correlation between steatosis and visceral fat thickness and suggested values for visceral fat thickness to allow the differentiation of normality from risk for steatohepatitis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AbstractThe authors review the main concepts regarding the importance of cleaning/disinfection of ultrasonography probes, aiming a better comprehension by practitioners and thus enabling strategies to establish a safe practice without compromising the quality of the examination and the operator productivity. In the context of biosafety, it is imperative to assume that contact with blood or body fluids represents a potential source of infection. Thus, in order to implement cleaning/disinfection practice, it is necessary to understand the principles of infection control, to consider the cost/benefit ratio of the measures to be implemented, and most importantly, to comprehend that such measures will not only benefit the health professional and the patient, but the society as a whole.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Objective: To estimate the prevalence and evaluate sonographic findings compatible with changes consistent with hepatic steatosis in patients referred for abdominal ultrasonography at four reference centers in Aracaju, SE, Brazil. Materials and Methods: Prospective, descriptive survey, with analytical and quantitative approach, comprising abdominal ultrasonography scans performed with a convex, dynamic 3.75 MHz transducer. Liver dimensions and parenchymal echotexture were evaluated, classifying hepatic steatosis into grades (1, 2 or 3). The SPSS® 22.0 software was used for statistical analysis, adopting p < 0.05 as significance level. Results: A total of 800 individuals (561 women and 239 men) were evaluated. The prevalence of steatosis was 29.1%, and the male patients were most affected, presenting with more advanced grades of disease (p = 0.021), as follows: 119 grade 1 (51.0%); 94 grade 2 (40.4%); and 20 grade 3 (8.6%). The median age patients' was 46 years. Conclusion: In the present study sample, the prevalence of hepatic steatosis was high, particularly in the male patients. Ultrasonography is suggested as a first choice for the diagnosis of this condition, considering its wide availability, low cost and absence of side effects or risks to the patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Results on the optimization of analytical methods for the determination of phosphorus in phosphino-polycarboxylate (PPCA), used frequently as scale inhibitor during oil production, by ICP-AES and ICP-MS are presented. Due to the complex matrix of production waters (brines) and their high concentration in inorganic phosphorus, the separation of organic phosphorus prior to its determination is necessary. In this work, minicolumns of silica immobilized C18 were used. Optimization of the separation step resulted in the following working conditions: (1) prewashing of the column with methanol (80% v/v); (2) use of a flow rate of 5 mL/min and 10 mL/min, respectively, for the preconditioning step and for percolation of the water sample; (3) final elution of organic phosphorus with 7 mL of buffer of H3BO3/NaOH (0.05 M, pH 9) with a flow rate of 1 mL/min. Sample detection limits (3s) for different combinations of nebulizers and spectrometric methods, based on 10 mL water aliquots, are: ICP-AES -Cross flow (47 mg/L) and Ultrasonic (18 mug/L); ICP-MS -Cross flow (1.2 mug/L), Cyclonic (0.7 mug/L) and Ultrasonic (0.5 mug/L). Typical recoveries of organic phosphorus are between 90 and 95% and the repeatability of the whole procedure is better than 10%. The developed methodology was applied successfully to samples from the oil-well NA 46, platform PNA 2, Campos basin, Brazil. Assessment of the PPCA inhibitor was possible at lower concentrations than achieved by current analytical methods, resulting in benefits such as reduced cost of chemicals, postponed oil production and lower environmental impacts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The reaction between antigen and antibody has been widely used in many strategies for the development of analytical methodology, due to its high specificity. The immuno-reaction has been successfully employed for the biosensor development. A focus on biosensor based on immunoassay coupled to amperometric transducer is presented.