142 resultados para Tratamento eletroquímico. Água produzida. Benzeno. Tolueno. Xileno

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The analysis of water samples containing volatile organic compounds has become an important task in analytical chemistry. Gas chromatography has been widely used for the analysis of volatile organic compounds in water. The headspace analysis shows as a principal characteristic the possibility of determination of the volatile components in drinking water. Benzene, Toluene and Xylene (BTX) are important compounds usually present in drinking water, from contamination by petroleum derivatives. Since they are toxic compounds even when present in low concentration levels, their determination is important in order to define the quality of the water. The sampling technique using headspace, coupled with gas chromatography as the separation method, showed to be suitable for BTX analysis in several samples at the mug/L (ppb) level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A disposição de lodo de estação de tratamento de água (LETA) em áreas degradadas é uma alternativa para a gestão de resíduos e pode promover a recuperação destas áreas. O objetivo deste trabalho foi avaliar o efeito da aplicação de LETA nos teores de macronutrientes, carbono orgânico total (COT) e condutividade eletrolítica (CE) em amostras de solo degradado pela mineração de cassiterita. O LETA pode ser disposto em áreas degradadas, já que eleva os teores de Ca, Mg, K e o valor de pH do solo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An alternative application of the humid sludge from the Passaúna WTP, located in Curitiba's metropolitan area, is proposed for concrete structures, partially replacing aggregates and cement. For the investigation, a reference concrete and four concrete mixtures with sludge were produced, and from these, two mixtures, containing 4% and 8% of sludge (m/m), were analyzed by different techniques: X ray fluorescence, X ray diffraction, thermo-gravimetric analysis, physicochemical analysis, compressive strength, etc. The properties were evaluated and the results indicate that the mixtures can be applied in different situations as cast structures for construction of concrete walls. Mixtures with more than 4% of sludge are restricted to applications where the workability of the concrete is not required, such as for residential pavements, sidewalks and stepping floors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The growing concern of environmental surveillance of the quality of hydric resources guides the development of research on management of residues generated in water treatment plants (WTP). Approximately 8.000 WTPs in Brazil operate without a treatment program of the residues, disposing these effluents in the environment. This work evaluated WTP discharges into watercourses by collecting superficial waters, sediments and benthic samples at the town of Registro, São Paulo State, Brazil. Even though superficial waters and benthic samples showed no further contamination, sediment analysis pointed out that aluminum deposits detected near sludge discharges may represent a potential risk to the environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The remediation of groundwater containing organochlorine compounds was evaluated using a reductive system with zero-valent iron, and the reductive process coupled with Fenton's reagent. The concentration of the individual target compounds reached up to 400 mg L-1 in the sample. Marked reductions in the chlorinated compounds were observed in the reductive process. The degradation followed pseudo-first-order kinetics in terms of the contaminant and was dependent on the sample contact time with the solid reducing agent. An oxidative test with Fenton's reagent, followed by the reductive assay, showed that tetrachloroethylene was further reduced up to three times the initial concentration. The destruction of chloroform, however, demands an additional treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present paper, the use of poly(styrene sulfonate) (PSS), produced from discarded polystyrene materials through heterogeneous and homogeneous processes, was investigated. The use of PSS for water treatment, using a kaolin suspension as wastewater model, reduced water turbidity for all the employed materials when compared to the blank analysis, without PSS. The most efficient polyelectrolyte was PSS cups obtained by homogeneous route. The same behavior was observed for real system. The homogeneous PSS cups showed a balance between a moderate molecular weight and high anionic character that improved flocks formation and water removal turbidity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Automotive gasoline consists of a complex mixture of flammable and volatile hydrocarbons derived from crude oil with carbon numbers within the range of 4-12 and boiling points range of 30-225 ºC. Its composition varies with the kind of crude oil and the type of refinery process that they undergone. Aromatics hydrocarbons, in particular benzene, toluene, ethylbenzene and isomeric xylenes (BTEX) are the toxic group constituents presents. GC-FID was employed to quantify these hydrocarbons in 50 commercial gasoline samples from Piauí state. Statistical analysis techniques, such as PCA and HCA were used to analyze the data. Moreover, several validation parameters were evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work reported here involved the characterization of sludges produced at water treatment plants in Jaboticabal-SP using FeCl3 as flocculant, and in Taquaritinga-SP and Manaus-AM using Al2(SO4)3 as flocculant. An evaluation was also made of the interaction of organic matter extracted from the sludges with different metal species. The results indicated that all the sludges produced at water treatment plants have an important agricultural potential and that their use depends on the characteristics of the raw water and the type of flocculant employed in conventional treatment. The humic substances extracted from the sludges showed different affinities for metal species, favoring eventual exchanges between potentially toxic metals and macro- and micronutrients. An alternative for the use of sludge in agriculture is to pretreat it to remove potentially toxic metals and enrich it with micro- and macronutrients that can be released to the plant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work the potentiality of photo-Fenton processes were investigated toward the degradation of aromatic hydrocarbons (BTXs) from water contaminated with gasoline. The main results demonstrated that BTXs can be quickly degraded by photo-Fenton process assisted by solar or artificial UV-A radiation, degradation that leads to generation of characteristic phenolic transient species (ie. phenol, hydroquinone and catechol). In the treatment of contaminated water by photo-Fenton processes assisted by solar light, complete BTXs removal was observed in reaction times of about 5 min. Mineralization of about 90% was also observed by applying a multiple H2O2 addition system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This survey determined the physical and chemical properties of the gravel place where urban sludge from Rio Descoberto's Water Treatment Plant is disposed. Physical, chemical and biological analysis of the soil samples (n=54), sludge samples (n=2), chemical coagulant (n=20) and samples from superficial waters (n=9) and water table (n=60) were performed. As results we can emphasize the horizontal distribution of mineral phases like gibbsite, organic material, exchanged Ca, available Mn and P on the soils are originated from the sludge. Some of these mobile elements could stimulate the growing of the vegetation, but they also could contaminate the water table.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective was to study the treatment of wastewater generated by the oil industry. This work consisted of tests of electroflocculation with alternate current (AC), and chemical coagulation. The removal efficiencies of organic load were evaluated by the removal of oils and greases, color and turbidity. The parameters investigated were the change in alternate current frequency, the initial pH, the distance between electrodes, the applied potential and time lapse. From the results, one may conclude that the electroflocculation process is potential applicability to the effluent studied, while chemical coagulation was not successful.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Com a realização deste trabalho, objetivou-se parametrizar a equação de evolução da perda de carga, para descrição do processo de filtração de água residuária da suinocultura. No preenchimento das colunas filtrantes, foram utilizados bagaço de cana-de-açúcar triturado, serragem de madeira e pergaminho de grãos de café. Dados de perda de carga em diferentes profundidades e tempos de operação dos filtros orgânicos foram coletados para ajuste das equações de perda de carga. Para as equações ajustadas, foram obtidos altos coeficientes de determinação, sendo que a significância dos coeficientes da regressão foi, na sua quase totalidade, de 1% de probabilidade, podendo ser utilizada na predição do comportamento dos filtros. As variáveis tempo de operação e profundidade das colunas filtrantes, constituídas pelos três materiais filtrantes, apresentaram comportamento quadrático na estimativa da perda de carga total. O tempo ideal de operação ininterrupta dos filtros, sem troca de material filtrante, foi de, aproximadamente, 1,5 h e, depois de corrido esse tempo, o material filtrante deverá ser substituído.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO Neste trabalho, avaliou-se o efeito combinado de duas unidades de tratamento na remoção de nitrogênio total Kjeldahl (NTK) e fósforo total (PT). As unidades avaliadas receberam alimentação contínua, sendo um reator anaeróbio de manta de lodo e fluxo ascendente tipo RAFA, com volume útil de 96 L, seguido de um sistema alagado construído (SAC) com capacidade para 237 L. O experimento foi conduzido em três fases, variando o tempo de detenção hidráulica (TDH) no reator anaeróbio de: 59 h, 19,5 h e 5 h, e no SAC 146 h, 48 h e 13 h, respectivamente, nas fases I, II e III. A carga orgânica volumétrica (COV) aplicada foi de 1,2; 1,3 e 13,0 kg m-3 d-1 de DQO no RAFA, e as taxas de aplicação superficial (TAS) no SAC foram de 120, 130 e 464 kg ha-1d-1 de NTK e 13; 51 e 240 kg ha-1 d-1de PT e de 850; 656 e 6.335 kg ha-1 d-1 de DQO. As eficiências de remoção de NTK e PT no sistema como um todo foram de, aproximadamente, 35%, não havendo diferença significativa entre as fases. Porém, em termos de COV removida, houve maior remoção com o aumento da carga aplicada. As características apresentadas pelo efluente do sistema nas diferentes fases não alcançaram os padrões ambientais para lançamento em cursos de água no Estado de Minas Gerais, dentre as variáveis avaliadas, mas seu potencial nutricional deve ser utilizado para produção agrícola.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO Objetivou-se, com a realização deste trabalho, determinar a eficiência de aeração e a capacidade do sistema de aeração em cascata em remover matéria orgânica da água residuária do processamento dos frutos do cafeeiro (ARC). O sistema de aeração foi constituído por cascata com 4,14 m de altura, distribuída em 23 degraus (altura, largura e comprimento de 0,18; 0,32 e 0,60 m, respectivamente), reservatório para a recepção/detenção da ARC escoada, por três horas, e reservatório de distribuição, de onde era recirculada no sistema. Durante a fase experimental, o sistema de tratamento ficou em operação por trinta dias, sendo a ARC recirculada três vezes por dia, numa vazão constante de 1 L s-1, e substituída a cada dez dias. A cada recirculação, amostras do afluente e efluente foram coletadas e analisadas. Com a utilização do sistema de aeração em cascatas, foi possível incorporar, em média, 0,2 mg L-1 de oxigênio a cada lance de 1 m de degraus na cascata. A eficiência de aeração na cascata foi de 0,128 ou 0,141, dependendo se foi considerado ou não o efeito salino na ARC. A alta concentração de material orgânico não permitiu que se detectassem grandes alterações na concentração de oxigênio dissolvido na ARC. O tempo de detenção ideal da ARC no tanque de recepção/detenção foi de 26 min.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO Na pecuária brasileira, tem-se destacado a suinocultura, cuja produção de carne foi apontada como a terceira maior do mundo, e como contrapartida os sistemas produtivos são, potencialmente, poluidores do ambiente. Os sistemas anaeróbios têm sido utilizados para tratamento de água residuária suinícola, necessitando de complementação para diminuir as cargas de nutrientes e reúso agrícola. Neste trabalho, avaliou-se o efeito combinado de duas unidades de tratamento na remoção de matéria orgânica, na forma de demanda química de oxigênio (DQO), sendo um reator anaeróbio de manta de lodo e fluxo ascendente tipo RAFA com volume útil de 96 L, seguido de um sistema alagado construído (SAC) com capacidade para 237 L. O experimento foi conduzido em três fases, variando-se o tempo de detenção hidráulica (TDH) no reator anaeróbio, de 59 h, 19,5 h e 5 h, e no SAC, 146 h, 48 h e 13 h, respectivamente, nas fases 1, 2 e 3. A carga orgânica volumétrica (COV) aplicada foi de 1,2; 1,3 e 13,0 kg m-3d-1 de DQO, e as taxas de aplicação superficial (TAS) no SAC foram de 850; 656 e 6335 kg ha-1 d-1 de DQO. As unidades combinadas removeram 0,07; 0,07 e 0,96 kg d-1 de DQO total e 0,03; 0,07 e 0,14 kg d-1 de DQO solúvel. As características apresentadas pelo efluente do sistema, nas diferentes fases, não alcançaram os padrões ambientais para lançamento em cursos de água, dentre as variáveis avaliadas.