7 resultados para Tetrahydrofuran (pTHF)

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the availability of alternative methods for drying tetrahydrofuran (THF), the use of the still apparatus, wherein a THF solution containing Na-bezophenone ketyl is heated to reflux, remains widespread. We herein propose a set of procedures to solve the problems usually faced in applying this drying technique. Moreover, a discussion is made on the chemical knowledge underlying such procedures. Safety and economy issues concerned with the operation of the THF still apparatus are also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neolignans, generated by oxydative dimerization of propenylphenol and/or allylphenol, undergo further modifying steps. These biosynthetic reactions, confirmed in vitro, include Cope, retro-Claisen and Claisen rearrangements. Additionally acid catalysis effects convertions of bicyclo [3.2.1] octanoid neolignans into hydrobenzofuranoid neolignans, or inversely of hydrobenzofuranoid neolignans into bicyclo [3.2.1] octanoid neolignans, of hydrobenzofuranoid neolignans into futoenone type neolignans, of tetrahydrofuran neolignans into aryltetralin neolignans, as well as modifications by Friedel - Crafts reactions and the transformation of aryltetralin neolignans into arylindanones by pinacoline - pinacolone type rearrangement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction and analytical evaluation of a coated graphite Al(III) ion-selective electrode, based on the ionic pair formed between the Al(F)n3-n anion and tricaprylylmethylammonium cation (Aliquat 336S) incorporated on a poly(vinylchloride) (PVC) matrix membrane are described. A thin membrane film of this ionic pair and dibutylphthalate (DBPh) in PVC was deposited directly on a cylindric graphite rod (2 cm length x 0.5 cm diameter) attached to the end of a glass tube using epoxy resin. The membrane solution was prepared by dissolving 40% (m/m) of PVC in 10 mL of tetrahydrofuran following addition of 45% (m/m) of DBPh and 15% (m/m) of the ionic pair. The effect of membrane composition, fluoride concentration, and several concomitants as potential interferences on the electrode response were investigated. The aluminium(III) ion-selective electrode showed a linear response ranging from 1.4 x 10-4 to 1.0 x 10-2 mol L-1, a detection limit of 4.0 x 10-5 mol L-1, aslope of -54.3±0.2mV dec-1 and a lifetime of more than 1 year (over 3000 determinations for each membrane). The slope indicates that the ion-selective electrode responds preferentially to the Al(F)4- species. Application of this electrode for the aluminium(III) determination in stomach anti-acid samples is reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A UV spectrophotometric method was developed and validated and a chromatographic method was adapted from the American Pharmacopeia for the analysis of Fluoxetine Hydrochloride capsules. Ethanol was used as solvent for the spectrophotometric method, with detection and determination at 276 nm. The separation for the chromatographic method was carried out using the reversed-phase column LC-8, triethylamine buffer, stabilizer free tetrahydrofuran and methanol (5:3.5:1.5), pH 6.0 as mobile phase and detection at 227 nm. The results obtained for both methods showed to be accurate, precise, robust and linear over the concentration range 100.00 - 300.00 µg/mL and 40.00 - 80.00 µg/mL of fluoxetine hydrochloride for the spectrophotometric and chromatographic methods, respectively. The accuracy of the methods was evaluated by a recovery test and showed results between 98.89 and 101.10%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple analytical method for extraction and quantification of lutein colorant added to yogurt was developed and validated. The method allowed complete extraction of carotenoids using tetrahydrofuran in vortex, followed by centrifugation, partition to diethyl ether/petroleum ether, and drying. The carotenoids dissolved in ethanol were quantified by UV-Vis spectrophotometry. This method showed linearity in the range tested (1.41-13.42 µg g-1), limits of detection and quantification of 0.42 and 1.28 µg g-1, respectively, low relative standard deviation (3.4%) and recovery ranging from 95 to 103%. The method proved reliable for quantification of lutein added to yogurt.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work studies the influence of the film deposition process on light emission performance and on threshold voltage of OLEDs, with architecture glass/ITO/PEDOT:PSS/PVK/Alq3/Al. The commercial PVK was dissolved in different solvents such as: chloroform, tetrahydrofuran, 1,2,4-trichlorobenzene and trimethylpentane. OLEDs were characterized by current-voltage and revealed a significant influence of the solvents, although all devices emitted green electroluminescence. A difference in threshold voltage up to 10 V was observed among OLEDs prepared from different solvents. The 1,2,4-trichlorobenzene showed best performance, presenting lowest treshold voltage (≈ 6 V), followed by tetrahydrofuran (≈ 8 V), trimethylpentane (≈ 14 V) and chloroform (≈ 16 V).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The possibility of using thiocyanate to determine iron(II) and/or iron(III) in water-acetone mixture has been re-examined as part of a systematic and comparative study involving metallic complexes of pseudohalide ligands. Some parameters that affect the complete oxidation of the ferrous cations, their subsequent complexation and the system stability have been studied to optimize the experimental conditions. Our results show the viability and potentiality of this simply methodology as an alternative analytical procedure to determine iron cations with high sensitivity, precision and accuracy. Studies on the calibration, stability, precision, and effect of various different ions have been carried out by using absorbance values measured at 480 nm. The analytical curve for the total iron determination obeys Beer's law (r = 0.9993), showing a higher sensitivity (molar absorptivity of 2.10x10(4) L cm-1 mol-1) when compared with other traditional systems (ligands) or even with the "similar" azide ion [1.53x10(4) L cm-1 mol-1, for iron-III/azide complexes, in 70% (v/v) tetrahydrofuran/water, at 396 nm]. Under such optimized experimental conditions, it is possible to determine iron in the concentration range from 0.5 to 2 ppm (15-65% T for older equipments, quartz cells of 1.00 cm). Analytical applications have been tested for some different materials (iron ores), also including pharmaceutical products for anemia, and results were compared with atomic absorption determinations. Very good agreement was obtained with these two different techniques, showing the potential of the present experimental conditions for the total iron spectrophotometric determinations (errors < 5%). The possibility of iron speciation was made evident by using another specific and auxiliary method for iron(II) or (III).