4 resultados para Static analysis
em Scielo Saúde Pública - SP
Resumo:
Abstract The growing interest in the usage of dietary fiber in food has caused the need to provide precise tools for describing its physical properties. This research examined two dietary fibers from oats and beets, respectively, in variable particle sizes. The application of automated static image analysis for describing the hydration properties and particle size distribution of dietary fiber was analyzed. Conventional tests for water holding capacity (WHC) were conducted. The particles were measured at two points: dry and after water soaking. The most significant water holding capacity (7.00 g water/g solid) was achieved by the smaller sized oat fiber. Conversely, the water holding capacity was highest (4.20 g water/g solid) in larger sized beet fiber. There was evidence for water absorption increasing with a decrease in particle size in regards to the same fiber source. Very strong correlations were drawn between particle shape parameters, such as fiber length, straightness, width and hydration properties measured conventionally. The regression analysis provided the opportunity to estimate whether the automated static image analysis method could be an efficient tool in describing the hydration properties of dietary fiber. The application of the method was validated using mathematical model which was verified in comparison to conventional WHC measurement results.
Resumo:
Urinalysis of acetone is important to monitor workers occupationally exposed to acetone and/or isopropanol, as well as in diagnosis of some diseases related to lipid metabolism impairment. This work shows a sensitive, simple and rapid static headspace-gas chromatographic procedure for quantitative determination of acetone in urine. The method was applied to measure acetone in 207 samples from general population volunteers, resulting in a mean level of 1.12 mg/L (± 0.47) and a range of 0.20 - 1.95 mg/L. The method is reproducible and reliable, making it suitable for routine analysis of acetone in urine.
Resumo:
The existence of a minimum storage capacity of grains as a condition for the maintenance of regulator physical stocks has been used as a strategic factor in the agribusiness expansion. However, in Brazil the storage infrastructure has not followed the growth of the agricultural sector. This fact is evident in the case of soybeans that currently represent 49% of grain production in the country, whose volume production has been increasing significantly over the years. This study aimed to predict the futureï needs of static storage capacity of soybeans from historical data to estimate the investment needed to install storage units in Brazil for the next five years. A statistic analysis of collected data allowed a forecast and identification of the number of storage units that should be installed to meet the storage needs of soybeans in the next five years. It was concluded that by 2015 the soybean storage capacity should be 87 million tons, and to store 49% of soybeans produced, 1,104 storage units should be installed at a cost of R$ 442 million.
Resumo:
Static lung volume (LV) measurements have a number of clinical and research applications; however, no previous studies have provided reference values for such tests using a healthy sample of the adult Brazilian population. With this as our main purpose, we prospectively evaluated 100 non-smoking subjects (50 males and 50 females), 20 to 80 years old, randomly selected from more than 8,000 individuals. Gender-specific linear prediction equations were developed by multiple regression analysis with total lung capacity (TLC), functional residual capacity (FRC), residual volume (RV), RV/TLC ratio and inspiratory capacity (IC) as dependent variables, and with age, height, weight, lean body mass and indexes of physical fitness as independent ones. Simpler demographic and anthropometric variables were as useful as more complex measurements in predicting LV values, independent of gender and age (R2 values ranging from 0.49 to 0.78, P<0.001). Interestingly, prediction equations from North American and European studies overestimated the LV at low volumes and underestimated them at high volumes (P<0.05). Our results, therefore, provide a more appropriate frame of reference to evaluate the normalcy of static lung volume values in Brazilian males and females aged 20 to 80 years.