77 resultados para Standard Mouse Neutralization Test

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine the rabies antibody level of twenty-four hyperimmune equine sera, Standard Mouse Neutralization (SMN) and Couterimmunoelectrophoresis (CIE) tests were carried out, both at the Instituto Butantan (IB) and Instituto Panamericano de Protección de Alimentos y Zoonosis (INPPAZ). Statistical analysis has shown a correlation (r) of 0.9317 between the SMN and CIE performed at the IB, while at the INPPAZ it scored 0.974. Comparison of CIE data of both laboratories yielded a correlation of 0.845. The CIE technique has shown to be as sensitive and efficient as the SMN in titrating antirabies hyperimmune equine sera. Based on CIE results, a simple, rapid and inexpensive technique, tilers of sera antibody can be reliably estimated in SMN test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The detection of rabies antibodies is extremely valuable for epidemiological studies, determination of immune status in man, animals, and for the diagnosis of the disease. Several serological procedures have been described for this purpose. The present study reports a comparison between counterimmunoelectrophoresis test (CIET) and mouse neutralization test (MNT) in the detection of antibodies against rabies virus from 212 serum samples of vaccinated dogs. The agreement between both techniques was 79.7% and a significative association was demonstrated. The correlation coefficients between MNT and the CIET titers was determined considering 88 samples showing positive results in both techniques [CIET = 2 and MNT = 5 (0.13 IU/ml)] and resulted r² = 0.7926 (p < 0.001). The performance of CIET system was technically simple, cheap and rapid, and thereby it could be useful for serological monitoring of dog vaccination campaigns as well as for individual analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the indirect immunoperoxidase virus neutralization (IPVN) and mouse neutralization test (MNT) to detect antibodies against rabies virus from vaccinated dogs and cattle. The IPVN was set up for the ability to measure 0.5 International Units/ml (IU) of antibody required by the World Health Organization and the Office International des Epizooties as the minimum response for proof of rabies immunization. IPVN was developed and standardized in chicken embryo related (CER) cell line when 141 dog and 110 cattle sera were applied by serial five-fold dilutions (1:5, 1:25, 1:125) as well as the positive and negative reference controls, all added in four adjacent wells, of 96-well microplates. A 50 µl amount of CVS32 strain dilution containing 50-200 TCID50/ml was mixed to each serum dilution, and after 90 min 50 µl of 3 x 10(5) cells/mlcell suspension added to each well. After five days of incubation, the monolayers were fixed and the IPVN test performed. The correlation coefficient between the MNT and IPVN performed in CER cells was r = 0.9949 for dog sera (n = 100) and r = 0.9307 for cattle sera (n = 99), as well as good specificity (94.7%), sensitivity (87.5%), and agreement (96.6%) were also obtained. IPVN technique can adequately identify vaccinated and unvaccinated animals, even from low-responding vaccinated animals, with the advantage of low cost and faster then MNT standard test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A virus antigenic characterization methodology using an indirect method of antibody detection ELISA with virus-infected cultured cells as antigen and a micro virus neutralisation test using EIA (NT-EIA) as an aid to reading were used for antigenic characterization of Jatobal (BeAn 423380). Jatobal virus was characterized as a Bunyaviridae, Bunyavirus genus, Simbu serogroup virus. ELISA using infected cultured cells as antigen is a sensitive and reliable method for identification of viruses and has many advantages over conventional antibody capture ELISA's and other tests: it eliminates solid phase coating with virus and laborious antigen preparation; it permits screening of large numbers of virus antisera faster and more easily than by CF, HAI, or plaque reduction NT. ELISA and NT using EIA as an aid to reading can be applicable to viruses which do not produce cytopathogenic effect. Both techniques are applicable to identification of viruses which grow in mosquito cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Humoral immune response using inactivated rabies vaccine was studied in 35 nelore cross-bred bovines of western region of São Paulo state. Ninety days after vaccination, 13 (92.8%) animals presented titers 30.5IU/ml, through mouse neutralization test. After 180 days, 9 (64.3%) sera showed titers 30.5IU/ml, after 270 days, only one (7.1%) showed a titer of 0.51IU/ml, and after 360 days, all animals showed titers < 0.5IU/ml. Group of animals receiving booster dose 30 days after vaccination presented, two months after, all with titers > 0.5IU/ml. At 180 days, 17 (80.9%) sera presented titers > 0.5IU/ml; at 270 days, 15 (71.4%), with titers 30.5IU/ml and at 360 days, 4 (19.0%), with titers 30.5IU/ml. Booster-dose ensured high levels of neutralizing antibodies for at least three months, and 240 days after revaccination, 71.4% of animals were found with titers 30.5IU/ml.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Saint Louis encephalitis virus (SLEV) primarily occurs in the Americas and produces disease predominantly in humans. This study investigated the serological presence of SLEV in nonhuman primates and horses from southern Brazil. Methods From June 2004 to December 2005, sera from 133 monkeys (Alouatta caraya, n=43; Sapajus nigritus, n=64; Sapajus cay, n=26) trap-captured at the Paraná River basin region and 23 blood samples from farm horses were obtained and used for the serological detection of a panel of 19 arboviruses. All samples were analyzed in a hemagglutination inhibition (HI) assay; positive monkey samples were confirmed in a mouse neutralization test (MNT). Additionally, all blood samples were inoculated into C6/36 cell culture for viral isolation. Results Positive seroreactivity was only observed for SLEV. A prevalence of SLEV antibodies in sera was detected in Alouatta caraya (11.6%; 5/43), Sapajus nigritus (12.5%; 8/64), and S. cay (30.8%; 8/26) monkeys with the HI assay. Of the monkeys, 2.3% (1/42) of A. caraya, 6.3% 94/64) of S. nigritus, and 15.4% (4/26) of S. cay were positive for SLEV in the MNT. Additionally, SLEV antibodies were detected by HI in 39.1% (9/23) of the horses evaluated in this study. Arboviruses were not isolated from any blood sample. Conclusions These results confirmed the presence of SLEV in nonhuman primates and horses from southern Brazil. These findings most likely represent the first detection of this virus in nonhuman primates beyond the Amazon region. The detection of SLEV in animals within a geographical region distant from the Amazon basin suggests that there may be widespread and undiagnosed dissemination of this disease in Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An indirect ELISA for determination of post-vaccination rabies antibody was applied. Purified rabies virus was used as antigen to coat plates, and staphylococcal protein A linked with horseradish peroxidase was used for detecting IgG antibody in human sera. Sera from humans, vaccinated with cell-culture vaccine or suckling-mouse-brain vaccine, were examined. ELISA results were compared to those obtained from the virus neutralization test. The mean and standard deviation of OD were determined for 126 negative sera (pre-vaccination) and for 73 sera from vaccinated persons showing antibody titers lower than 0.5 IU/ml. Results were defined as ELISA -positive, -negative or -doubtful. Establishment of a doubtful region reduced the number of sera otherwise classified as positive (false-positive sera). In this way, the sensitivity, specificity and agreement values were respectively 87.5%, 92.4% and 88.5%. No significant differences were observed in these values when the group vaccinated with cell-culture vaccine and the group vaccinated with suckling-mouse-brain vaccine were compared. It was shown that much of the disagreement between the values obtained by neutralization test and ELISA occurred in sera obtained at the beginning of the immunization process, and was probably due to the presence of IgM in the serum samples, detected only by the former test. This ELISA method can be used as a screening test in rabies laboratories regardless of the kind of vaccine used for immunization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During an epidemiological survey of acute respiratory infection in Rio de Janeiro, among 208 adenovirus isolates, we found two strains that we were not able, by a standard neutralization procedure, to distinguish between type 3 or 7. However, DNA restriction pattern for the two strains with different enzymes were analyzed and showed a typical Ad3h profile. Using a cross-neutralization test in which both Ad3p and Ad7p antisera were used in different concentration against 100 TCID50 of each adenovirus standard and both isolates, we were able to confirm that the two isolates belong to serotype 3. An hemagglutination inhibition test also corroborated the identification of both strains as adenovirus type 3. Comparing Ad3h and Ad3p genome, we observed 16 different restriction enzyme sites, three of which were located in genomic regions encoding polypeptides involved in neutralization sites

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rabies is a neurotropic disease that is often lethal. The early diagnosis of rabies infection is important and requires methods that allow for the isolation of the virus from animals and humans. The present study compared a modified shell vial (MSV) procedure using 24-well tissue culture plates with the mouse inoculation test (MIT), which is considered the gold standard for rabies virus isolation. Thirty brain samples (25 positive and 5 negative by the fluorescent antibody test) obtained from different animal species at the National Institute of Hygiene Rafael Rangel in Caracas, Venezuela, were studied by the MIT and MSV assays. Nine samples (36%) were positive at 24 h, 10 (40%) were positive at 48 h and six (24%) were positive at 72 h by the MSV assay. With the MIT assay, 76% were positive at six days post inoculation and 12% were positive at 12 and 18 days post inoculation. One sample that was negative according to the MSV assay was positive with MIT on the 12th day. The MSV procedure exhibited a sensitivity of 96.2%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value 80%. This procedure allowed for rapid rabies virus detection. MIT can be employed as an alternative method in laboratories without tissue culture facilities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The human anti-rabies pre-exposure treatment currently used in Brazil, employing a 1-ml dose of suckling mouse brain vaccine (SMBV) administered on days 0, 2, 4 and 28, was compared to an alternative treatment with two 1 ml-doses on day 0, and one 1 ml-dose injected on days 7 and 21. The latter induced higher virus-neutralizing antibody (VNA) titers on day 21. Both Brazilian rabies vaccines produced with PV or CVS rabies virus strains were tested. Two additional volunteer vaccinee groups, receiving the pre-exposure and the abbreviated post-exposure schedules recommended by the WHO using cell-culture vaccine (CCV) produced with PM rabies virus strain, were included as reference. The VNA were measured against both PV and CVS strains on days 21, 42 and 180 by the cell-culture neutralization microtest. The PV-SMBV elicited higher seroconversion rates and VNA by day 21 than the CVS-SMBV. Both, however, failed to induce a long-term immunity, since VNA titers were <0.5 IU/ml on day 180, regardless of the schedule used. Cell-culture vaccine always elicited very high VNA on all days of collection. When serum samples from people receiving mouse brain tissue were titrated against the PV and CVS strains, the VNA obtained were similar, regardless of the vaccinal strain and the virus used in the neutralization test. These results contrast with those obtained with sera from people receiving PM-CCV, whose VNA were significantly higher when tested against the CVS strain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occured with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescense (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simplified fluorescence inhibition microtest (SFIMT) was standardized for the evaluation of antirabies serum neutralizing antibodies based on the rapid fluorescent focus inhibition test (RFFIT) and the fluorescence inhibition microtest (FIMT). The simplified test showed reproductibility similar to that of the FIMT with advantages as easier executation and quicker reading. A simple pre-treatment of Brazilian microplates produced for immune enzymatic assays (PROSIL) gave equivalent results and substantial coast reduction, in relation to imported plates (DIFCO). The simplified test can be easily implemented in less sophisticated laboratories, as alternative to the mouse serum neutralization test, still the most largely employed in Brazil, or even to others as RFFIT and FIMT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Rabies is an important zoonosis that occurs in mammals, with bats acting as Lyssavirus reservoirs in urban, rural and natural areas. Rabies cases in bats have been recorded primarily in urban areas in Northwestern State of São Paulo since 1998. This study investigated the circulation of rabies virus by seeking to identify the virus in the brain in several species of bats in this region and by measuring rabies-virus neutralizing antibody levels in the hematophagous bat Desmodus rotundus. Methods From 2008 to 2012, 1,490 bat brain samples were sent to the Universidade Estadual Paulista (UNESP) Rabies Laboratory in Araçatuba, and 125 serum samples from vampire bats that were captured in this geographical region were analyzed. Results Rabies virus was detected in the brains of 26 (2%) of 1,314 non-hematophagous bats using the fluorescent antibody test (FAT) and the mouse inoculation test (MIT). None of the 176 hematophagous bat samples were positive for rabies virus when a virus detection test was utilized. Out of 125 vampire bat serum samples, 9 (7%) had levels of rabies virus neutralization antibodies (RVNAs) that were higher than 0.5IU/mL; 65% (81/125) had titers between 0.10IU/mL and 0.5IU/mL; and 28% (35/125) were negative for RVNAs using the simplified fluorescent inhibition microtest (SFIMT) in BHK21 cells. The observed positivity rate (1.7%) was higher than the average positivity rate of 1.3% that was previously found in this region. Conclusions The high percentage of vampire bats with neutralizing antibodies suggests that recent rabies virus exposure has occurred, indicating the necessity of surveillance measures in nearby regions that are at risk to avoid diffusion of the rabies virus and possible rabies occurrences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples h-1 can be carried out with the proposed flow-batch analyser.