3 resultados para Smart Camera
em Scielo Saúde Pública - SP
Resumo:
In order to evaluate the efficiency of different mammalian survey methods, we compared traditional sampling techniques (use of camera-traps on roads and artificial trails, track censuses, and direct field visualization) with an alternative sampling design (camera-traps positioned in natural areas such as natural trails and shelters). We conducted the study in a deciduous Atlantic-Forest park in southern Brazil, and additionally compared our results with a previous intensive study carried out in the same area. Our considerably smaller sampling effort (example: 336 trap.day for our camera-traps versus 2,154 trap.day for the earlier study) registered the presence of 85% of the local known species, with camera-traps being 68% efficient. Moreover, shelter camera-traps revealed a different species composition regarding most of other sampling methods. This sampling strategy involving natural forest sites was therefore able to effectively optimize the chances of evaluating species composition in a shorter period, especially with respect to lower-density and cryptic species, as well as to detect species that avoid open, disturbed sites such as roads and man-made forest trails.
Resumo:
The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target’s three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.