48 resultados para Simplified procedure

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid and sensitive method is described for the determination of clofentezine residues in apple, papaya, mango and orange. The procedure is based on the extraction of the sample with a hexane:ethyl acetate mixture (1:1, v/v) and liquid chromatographic analysis using UV detection. Mean recoveries from 4 replicates of fortified fruit samples ranged from 81% to 96%, with coefficients of variation from 8.9% to 12.5%. The detection and quantification limits of the method were of 0.05 and 0.1 mg kg-1, respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occured with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescense (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simplified methodology for the quantitative electroelution of proteins from polyacrylamide gels is described. After staining with Coomassie Brilliant Blue R 250, the identified bands are excised from the gel and the proteins eluted using a procedure developed for use in conventional tube gel electrophoresis equipment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work was to develop a simplified numerical procedure for the estimation of accumulated monthly hours of solarized soil temperatures. The proposed model requires monthly means of daily solar radiation and maximum air temperature as input data, and a daily pattern of temperature variation assumed to be sine-shaped. The procedure was verified using observations made during the years 1992 and 1993 in Jaguariúna, SP. The proposed procedure can predict monthly temperature hours at 10 cm depth in the solarized soil, with acceptable accuracy, in the region for which it was developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In search of an efficient but simple, low cost procedure for the serodiagnosis of Toxoplasmosis, especially suited for routine laboratories facing technical and budget limitations as in less developed countries, the diagnostic capability of Hematoxo® , an hemagglutination test for toxoplasmosis, was evaluated in relation to a battery of tests including IgG- and IgM-immunofluorescence tests, hemagglutination and an IgM-capture enzymatic assay. Detecting a little as 5 I.U. of IgG antitoxoplasma antibodies, Hematoxo® showed a straight agreement as to reactivity and non-reactivity for the 443 non-reactive and the 387 reactive serum samples, included in this study. In 23 cases presenting a serological pattern of acute toxoplasmosis and showing IgM antibodies, Hematoxo® could detect IgM antibodies in 18, indicated by negativation or a significant decrease in titers as a result of treating samples with 2-mercapto-ethanol. However, a neat increase in sensitivity for IgM specific antibodies could be achieved by previously removing IgG from the sample, as demonstrated in a series of acute toxoplasmosis sera. A simple procedure was developed for this purpose, by reconstituting a lyophilized suspension of Protein A - rich Staphylococcus with the lowest serum dilution to be tested. Of low cost and easy to perform, Hematoxo® affords not only a practical qualitative procedure for screening reactors and non-reactors, as in prenatal services, but also quantitative assays that permit to titrate antibodies as well as to identify IgM antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mutagenic activities of 16 anti-parasite drugs were screened by the Simultest in both qualitative (spot test) and quantitative (plate incorporation) assays with a Salmonella typhimurium pool composed by the indicator strains TA97, TA 98, TA100 and TA102. Four anti Chagas' disease drugs (nifurtimox, benznidazole, CL 64,855, and MK 436) and two anti-amebae drugs (metronidazole and tinidazole) gave positive results in qualitative tests and incorporation of rat liver microsomes did not alter the results. Comparative dose response curves of the mutagenic activities of CL 64,855, metronidazole and benznidazole obtained by the simultest and by individual Salmonella indicator strains demonstrated that both approachs have similar sensitivities. The results corroborate the validity of the Simultest, as a simplified, fast and economic version of the Ames test in preliminary screening of potential mutagenic drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simplified fluorescence inhibition microtest (SFIMT) was standardized for the evaluation of antirabies serum neutralizing antibodies based on the rapid fluorescent focus inhibition test (RFFIT) and the fluorescence inhibition microtest (FIMT). The simplified test showed reproductibility similar to that of the FIMT with advantages as easier executation and quicker reading. A simple pre-treatment of Brazilian microplates produced for immune enzymatic assays (PROSIL) gave equivalent results and substantial coast reduction, in relation to imported plates (DIFCO). The simplified test can be easily implemented in less sophisticated laboratories, as alternative to the mouse serum neutralization test, still the most largely employed in Brazil, or even to others as RFFIT and FIMT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supernatant of boiled spleen saline-suspensions of Yersinia pestis experimentally infected animals were used as template for PCR amplification without DNA extraction. PCR sensitivity was enhanced by a second round of amplification (Nested). No amplification was observed from non-infected animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show here a simplified RT-PCR for identification of dengue virus types 1 and 2. Five dengue virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD as a negative control, were used in this study. C6/36 cells were infected and supernatants were collected after 7 days. The RT-PCR, done in a single reaction vessel, was carried out following a 1/10 dilution of virus in distilled water or in a detergent mixture containing Nonidet P40. The 50 µl assay reaction mixture included 50 pmol of specific primers amplifying a 482 base pair sequence for dengue type 1 and 210 base pair sequence for dengue type 2. In other assays, we used dengue virus consensus primers having maximum sequence similarity to the four serotypes, amplifying a 511 base pair sequence. The reaction mixture also contained 0.1 mM of the four deoxynucleoside triphosphates, 7.5 U of reverse transcriptase, 1U of thermostable Taq DNA polymerase. The mixture was incubated for 5 minutes at 37ºC for reverse transcription followed by 30 cycles of two-step PCR amplification (92ºC for 60 seconds, 53ºC for 60 seconds) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized by UV light after staining with ethidium bromide solution. Low virus titer around 10 3, 6 TCID50/ml was detected by RT-PCR for dengue type 1. Specific DNA amplification was observed with all the Brazilian dengue strains by using dengue virus consensus primers. As compared to other RT-PCRs, this assay is less laborious, done in a shorter time, and has reduced risk of contamination

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report an adaptation of a technique for the blood sample collection (GFM) as well as for the extraction and amplification of Plasmodium DNA for the diagnosis of malaria infection by the PCR/ELISA. The method of blood sample collection requires less expertise and saves both time and money, thus reducing the cost by more than half. The material is also suitable for genetic analysis in either fresh or stored specimens prepared by this method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Studies strongly indicate Dientamoeba fragilis as one of the causes of diarrhea in human immunodeficiency virus (HIV) patients. METHODS: The objective of the present study was to evaluate the prevalence of D. fragilis associated with the causes of diarrhea in 82 HIV/ AIDS patients hospitalized at the Instituto de Infectologia Emílio Ribas from September 2006 to November 2008. RESULTS: In total, 105 samples were collected from 82 patients. Unprotected sex was the most frequent cause of HIV infection (46.3%), followed by the use of injectable or non-injectable drugs (14.6%). Patients presented with viral loads of 49-750,000 copies/ mL (average: 73,849 ± 124,850 copies/mL) and CD4 counts ranging of 2-1,306 cells/mm³ (average: 159 ± 250 cells/mm³). On an average, the odds of obtaining a positive result by using the other techniques (Hoffman, Pons and Janer or Lutz; Ritchie) were 2.7 times higher than the chance of obtaining a positive result by using the simplified iron hematoxylin method. Significant differences were found between the methods (p = 0.003). CONCLUSIONS: The other techniques can detect a significantly greater amount of parasites than the simplified iron hematoxylin method, especially with respect to Isospora belli, Cryptosporidium sp., Schistosoma mansoni, and Strongyloides stercoralis, which were not detected using hematoxylin. Endolimax nana and D. fragilis were detected more frequently on using hematoxylin, and the only parasite not found by the other methods was D. fragilis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The objective of this study is to evaluate the benefits of drainage in the Stoppa procedure for inguinal repair. PATIENTS AND METHODS: The use of a suction drain was randomized at the end of the surgical intervention in 26 male patients undergoing inguinal hernia repair, divided into 2 groups: Group A, 12 patients undergoing drainage, and group B, 14 patients not undergoing drainage. On the second postoperative day, all patients underwent abdominal pelvic computed tomography scan examination to detect the presence of abdominal fluid collection. RESULTS: In group A, no patient developed fluid collection in the preperitoneal space, and 1 patient presented with an abscess in the preperitoneal space on the 15th postoperative day. In group B, 12 patients presented with fluid collections in the preperitoneal space on computed tomography scan evaluation. However, only 3 patients presented minor complications. None of the patients developed a major complication. CONCLUSION: The use of suction drainage with the Stoppa procedure does not provide any benefit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os parâmetros do "Simplified Simple Biosphere Model"-SSiB foram validados e posteriormente calibrados para os sítios de pastagem da Fazenda Nossa Senhora Aparecida (62º22'W; 10º45'S) e de floresta da Reserva Biológica do Jaru (62º22'W; 10º45'S), ambos situados no estado de Rondônia. Foram utilizadas medidas micrometeorológicas e hidrológicas obtidas durante o período seco de 2001, como parte do Experimento de Grande Escala da Biosfera-Atmosfera na Amazônia - LBA. Os resultados indicam que o modelo simulou bem o saldo de radiação, tanto na pastagem quanto na floresta. O fluxo de calor latente foi superestimado nos dois sítios nos períodos de simulação, o que deve estar relacionado aos parâmetros utilizados no cálculo dessa variável. O modelo subestimou o fluxo de calor sensível na pastagem e na floresta, principalmente no período noturno; porém, para a floresta, os valores foram mais próximos daqueles observados. Com os parâmetros ajustados, melhores estimativas dos fluxos de calor latente e de calor sensível foram geradas e, conseqüentemente, representou melhor as partições de energia na floresta e na pastagem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the presence and the prevalence of arrhythmias and the variability of the heart rate in the medium-term postoperative period following the maze procedure for chronic atrial fibrillation (AF). METHODS: Seventeen patients with a mean age of 51.7±12.9 years, who previously underwent the maze procedure without cryoablation for chronic atrial fibrillation, were evaluated with the 24 hour electrocardiogram (ECG) - Holter monitoring from the 6th month after the operation. Valvular and coronary procedures were concomitantly performed. RESULTS: The mean heart rate during Holter monitoring was 82±8bpm; the maximal heart rate was 126 ± 23bpm and the minimal heart rate 57±7bpm. Sinus rhythm was found in 10 (59%) patients and atrial rhythm was found in 7 (41%). Supraventricular extrasystoles had a rate of 2.3±5.5% of the total number of heartbeats and occurred in 16 (94%) patients. Six (35%) patients showed nonsustained atrial tachycardia. Ventricular extrasystoles, with a rate of 0.8±0.5% of the total heartbeats, occurred in 14 (82%) patients. The chronotropic competence was normal in 9 (53%) patients and attenuated in 8 (47%). The atrioventricular conduction (AV) was unchanged in 13 (76%) patients and there were 4 (24%) cases of first degree atrioventricular block (AVB). CONCLUSION: After the maze procedure, the values for the mean heart rate, AV conduction and chronotropic competence approach the normal range, although some cases show attenuation of the chronotropic response, first degree AV block or benign arrhythmias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To develop a simplified questionnaire for self-evaluation by adolescents of foods associated with the risk of coronary diseases. METHODS: Frequency questionnaires about 80 foods were answered by representative samples of 256 adolescents aged 12 to 19 from Rio de Janeiro as part of the Nutrition and Health Research project. The dependent variable was the serum cholesterol predicting equation as influenced by diet, and the independent variables were the foods. The variables were normalized and, using Pearson's correlation coefficient, those with r>0.10 were selected for the regression model. The model was analyzed for sex, age, random sample, and total calories. Those food products that explained 85% of the cholesterol variation equation were present in the caloric model, and contained trans fatty acids were selected for the questionnaire. RESULTS: Sixty-five food products had a statistically significant correlation (P<0.001) with the dependent variable. The simplified questionnaire included 9 food products present in all tested models: steak or broiled meat, hamburger, full-fat cheese, French fries or potato chips, whole milk, pies or cakes, cookies, sausages, butter or margarine. The limit of the added food points for self-evaluation was 100, and over 120 points was considered excessive. CONCLUSION: The scores given to the food products and the criteria for the evaluation of the consumption limits enabled the adolescents to get to know and to balance their intake.