140 resultados para Signal detection

em Scielo Saúde Pública - SP


Relevância:

60.00% 60.00%

Publicador:

Resumo:

ELISAs have been applied to pesticide residue analysis due to their high sensitivity and selectivity. However, some ELISAs performance may be affected by matrix components. In this work, ELISA for carbaryl in water samples was checked for interference by naturally occurring fulvic acids. The results suggested that the high fulvic acid concentration (ž³30 mg L-1) and acidic pH conditions (pH 4.0) interfere with the signal detection decreasing the method sensitivity. A dilution of the samples and adjust to pH 8.0 are appropriate to minimize the matrix interferences in the ELISA method. Good correlation between ELISA and HPLC-DAD results was observed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To assess signal-averaged electrocardiogram (SAECG) for diagnosing incipient left ventricular hypertrophy (LVH). METHODS: A study with 115 individuals was carried out. The individuals were divided as follows: GI - 38 healthy individuals; GII - 47 individuals with mild to moderate hypertension and normal findings on echocardiogram and ECG; and GIII - 30 individuals with hypertension and documented LVH. The magnitude vector of the SAECG was analyzed with the high-pass cutoff frequency of 40 Hz through the bidirectional four-pole Butterworth high-pass digital filter. The mean quadratic root of the total QRS voltage (RMST) and the two-dimensional integral of the QRS area of the spectro-temporal map were analyzed between 0 and 30 Hz for the frequency domain (Int FD), and between 40 and 250 Hz for the time domain (Int TD). The electrocardiographic criterion for LVH was based on the Cornell Product. Left ventricular mass was calculated with the Devereux formula. RESULTS: All parameters analyzed increased from GI to GIII, except for Int FD (GII vs GIII) and RMST log (GII vs GIII). Int TD showed greater accuracy for detecting LVH with an appropriate cutoff > 8 (sensitivity of 55%, specificity of 81%). Positive values (> 8) were found in 56.5% of the G II patients and in 18.4% of the GI patients (p< 0.0005). CONCLUSION: SAECG can be used in the early diagnosis of LVH in hypertensive patients with normal ECG and echocardiogram.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method to detect Apple stem grooving virus (ASGV) based on reverse transcription polymerase chain reaction (RT-PCR) was developed using primers ASGV4F-ASGV4R targeting the viral replicase gene, followed by a sandwich hybridisation, in microtiter plates, for colorimetric detection of the PCR products. The RT-PCR was performed with the Titan™ RT-PCR system, using AMV and diluted crude extracts of apple (Malus domestica) leaf or bark for the first strand synthesis and a mixture of Taq and PWO DNA polymerase for the PCR step. The RT-PCR products is hybridised with both a biotin-labelled capture probe linked to a streptavidin-coated microtiter plate and a digoxigenin (DIG)-labelled detection probe. The complex was detected with an anti-DIG conjugate labelled with alkaline phosphatase. When purified ASGV was added to extracts of plant tissue, as little as 400 fg of the virus was detected with this method. The assay with ASGV4F-ASGV4R primers specifically detected the virus in ASGV-infected apple trees from different origins, whereas no signal was observed with amplification products obtained with primers targeting the coat protein region of the ASGV genome or with primers specific for Apple chlorotic leaf spot virus (ACLSV) and Apple stem pitting virus (ASPV). The technique combines the power of PCR to increase the number of copies of the targeted gene, the specificity of DNA hybridization, and the ease of colorimetric detection and sample handling in microplates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the main problems related to the transport and manipulation of multiphase fluids concerns the existence of characteristic flow patterns and its strong influence on important operation parameters. A good example of this occurs in gas-liquid chemical reactors in which maximum efficiencies can be achieved by maintaining a finely dispersed bubbly flow to maximize the total interfacial area. Thus, the ability to automatically detect flow patterns is of crucial importance, especially for the adequate operation of multiphase systems. This work describes the application of a neural model to process the signals delivered by a direct imaging probe to produce a diagnostic of the corresponding flow pattern. The neural model is constituted of six independent neural modules, each of which trained to detect one of the main horizontal flow patterns, and a last winner-take-all layer responsible for resolving when two or more patterns are simultaneously detected. Experimental signals representing different bubbly, intermittent, annular and stratified flow patterns were used to validate the neural model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ventricular late potentials are low-amplitude signals originating from damaged myocardium and detected on the body surface by ECG filtering and averaging. Digital filters present in commercial equipment may interfere with the ability of arrhythmia stratification. We compared 40-Hz BiSpec (BI) and classical 40- to 250-Hz band-pass Butterworth bidirectional (BD) filters in terms of impact on time domain variables and diagnostic properties. In a transverse retrospective age-adjusted case-control study, 221 subjects with sinus rhythm without bundle branch block were divided into three groups after signal-averaged ECG acquisition: GI (N = 40), clinically normal controls, GII (N = 158), subjects with coronary heart disease without sustained monomorphic ventricular tachycardia (SMVT), and GIII (N = 23), subjects with heart disease and documented SMVT. Conventional variables analyzed from vector magnitude data after averaging to 0.3 µV final noise were obtained by application of each filter to the averaged signal, and evaluated in pairs by numerical comparison and by diagnostic agreement assessment, using conventional and optimized thresholds of normality. Significant differences were found between BI and BD variables in all groups, with diagnostic results showing significant disagreement between both filters [kappa value of 0.61 (P<0.05) for GII and 0.31 for GIII (P = NS)]. Sensitivity for SMVT was lower with BI than with BD (65.2 vs 91.3%, respectively, P<0.05). Filters provided significantly different numerical and diagnostic results and the BI filter showed only limited clinical application to risk stratification of ventricular arrhythmia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to develop a classifier able to discriminate between healthy controls and dyspeptic patients by analysis of their electrogastrograms. Fifty-six electrogastrograms were analyzed, corresponding to 42 dyspeptic patients and 14 healthy controls. The original signals were subsampled, filtered and divided into the pre-, post-, and prandial stages. A time-frequency transformation based on wavelets was used to extract the signal characteristics, and a special selection procedure based on correlation was used to reduce their number. The analysis was carried out by evaluating different neural network structures to classify the wavelet coefficients into two groups (healthy subjects and dyspeptic patients). The optimization process of the classifier led to a linear model. A dimension reduction that resulted in only 25% of uncorrelated electrogastrogram characteristics gave 24 inputs for the classifier. The prandial stage gave the most significant results. Under these conditions, the classifier achieved 78.6% sensitivity, 92.9% specificity, and an error of 17.9 ± 6% (with a 95% confidence level). These data show that it is possible to establish significant differences between patients and normal controls when time-frequency characteristics are extracted from an electrogastrogram, with an adequate component reduction, outperforming the results obtained with classical Fourier analysis. These findings can contribute to increasing our understanding of the pathophysiological mechanisms involved in functional dyspepsia and perhaps to improving the pharmacological treatment of functional dyspeptic patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pancreatic adenocarcinoma is important in oncology because of its high mortality rate. Deaths may be avoided if an early diagnosis could be achieved. Several types of tumors overexpress gastrin-releasing peptide receptors (GRPr), including pancreatic cancer cells. Thus, a radiolabeled peptide derivative of gastrin-releasing peptide (GRP) may be useful as a specific imaging probe. The purpose of the present study was to evaluate the feasibility of using99mTc-HYNIC-βAla-Bombesin(7-14)as an imaging probe for Capan-1 pancreatic adenocarcinoma. Xenographic pancreatic tumor was developed in nude mice and characterized by histopathological analysis. Biodistribution studies and scintigraphic images were carried out in tumor-bearing nude mice. The two methods showed higher uptake by pancreatic tumor when compared to muscle (used as control), and the tumor-to-muscle ratio indicated that99mTc-HYNIC-βAla-Bombesin(7-14)uptake was four-fold higher in tumor cells than in other tissues. Scintigraphic images also showed a clear signal at the tumor site. The present data indicate that99mTc-HYNIC-βAla-Bombesin(7-14)may be useful for the detection of pancreatic adenocarcinoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study were a) to assess the ability of primary care doctors to make accurate ratings of psychiatric disturbance and b) to evaluate the use of a case-finding questionnaire in the detection of psychiatric morbidity. The estudy took place in three primary care clinics in the city of São Paulo, Brazil, during a six-month survey. A time sample of consecutive adult attenders were asked to complete a case-finding questionnaire for psychiatric disorders (the Self Report Questionnaire - SRQ) and a subsample were selected for a semi-structured psychiatric interview (the Clinical Interview Schedule - CIS). At the end of the consultation the primary care doctors were asked to assess, in a standardized way, the presence or absence of psychiatric disorder; these assessments were then compared with that ratings obtained in the psychiatric interview. A considerable proportion of minor psychiatric morbidity remained undetected by the three primary care doctors: the hidden morbidity ranged from 22% to 79%. When these were compared to those of the case-finding questionnaire, they were consistently lower, indicating that the use of these instruments can enhance the recognition of psychiatric disorders in primary care settings. Four strategies for adopting the questionnaire are described, and some of the clinical consequences of its use are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of studies in the field of Epidemiological Psychiatry have been performed over the last two decades, and these have focused on the ability of primary care physicians to detect emotional disorders in the patients that attend their practices. The scientific methodology utilized in these studies is the subject of this review, which contains a discussion concerning: a) interviewer awareness bias; b) accuracy of the instruments and c) medical and psychological concepts involved in defining minor emotional disorders. Suggestions for change in the methodology are made in each of the sections of the review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryptosporidium sp., a coccidian parasite usually found in the faeces of cattle, has been recently implicated as an agent of human intestinal disease, mainly in immunocompromised patients. In the study realized, by an indirect immunofluorescence technique, specific immunoglobulins (IgG and IgM) have been demonstrated in human serum against Cryptosporidium oocysts. Purified oocysts were used as antigens in the indirect immunofluorecence assay. After analyzing this test in sera from selected groups of patients, the frequency of both specific IgG and IgM of immunocompetent children who were excreting oocysts in their faeces was 62% and in children with negative excretion of oocysts was 20% and 40%, respectively. In adults infected with the human immunodeficiency virus (HIV) and who were excreting Cryptosporidium in their stools, the frequency was 57% for IgG but only 2% for IgM. Twenty three percent of immunocompromised adults with not determined excretion of oocysts in their stools had anti-Cryptosporidium IgG in their sera. Children infected with human immunodeficiency virus had no IgM and only 14% had IgG detectable in their sera. The indirect immunoflorescence assay, when used with other parasitological techniques appears to be useful for retrospective population studies and for diagnosis of acute infection. The humoral immune response of HIV positive patients to this protozoan agent needs clarification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVES: To detect anti-Giardia lamblia serum antibodies in healthy children attending public day care centers and to assess serological tests as tools for estimating the prevalence of G. lamblia in endemic areas. METHODS: Three separate stool specimens and filter paper blood samples were collected from 147 children ranging from 0 to 6 years old. Each stool sample was processed using spontaneous sedimentation and zinc sulfate flotation methods. Blood samples were tested by indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assay (ELISA) for Giardia IgG. RESULTS AND CONCLUSIONS: Of 147 individuals tested, 93 (63.3%) showed Giardia cysts in their feces. Using IIF and ELISA, serum antibodies were detected in 93 (63.3%) and 100 (68%) samples , respectively. Sensitivity of IIF and ELISA was 82% and 72%, respectively. However, ELISA revealed to be less specific (39%) than IIF (70%). IIF also showed a higher concordance with microscopic examination than ELISA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To comparatively detect A. actinomycetemcomitans and F. nucleatum from periodontal and healthy sites. METHODS: Subgingival clinical samples from 50 periodontitis adult patients and 50 healthy subjects were analyzed. Both organisms were isolated using a trypticase soy agar-bacitracin-vancomycin (TSBV) medium and detected by PCR. Conventional biochemical tests were used for bacteria identification. RESULTS: A. actinomycetemcomitans and F. nucleatum were isolated in 18% and 20% of the patients, respectively, and in 2% and 24% of healthy subjects. Among A. actinomycetemcomitans isolates, biotype II was the most prevalent. Primer pair AA was 100% sensitive in the detection of A. actinomycetemcomitans from both subject groups. Primers ASH and FU were also 100% sensitive to detect this organism in healthy subject samples. Primer pair FN5047 was more sensitive to detect F. nucleatum in patients or in healthy samples than primer 5059S. Primers ASH and 5059S were more specific in the detection of A. actinomycetemcomitans and F. nucleatum, respectively, in patients and in healthy subject samples. CONCLUSIONS: PCR is an effective tool for detecting periodontal pathogens in subgingival samples, providing a faster and safer diagnostic tool of periodontal diseases. The method's sensitivity and specificity is conditioned by the choice of the set of primers used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT This study aimed to describe the digital disease detection and participatory surveillance in different countries. The systems or platforms consolidated in the scientific field were analyzed by describing the strategy, type of data source, main objectives, and manner of interaction with users. Eleven systems or platforms, developed from 1996 to 2016, were analyzed. There was a higher frequency of data mining on the web and active crowdsourcing as well as a trend in the use of mobile applications. It is important to provoke debate in the academia and health services for the evolution of methods and insights into participatory surveillance in the digital age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IIF in the detection of invasive and classic enteropathogenic E. coli and Shigella serotypes was compared with traditional coproculture methods. IIP results agreed with the coproculture findings in 128 out of 140 cases tested for enteropathogenic E. coli (91%) and in 108 out of 112 for Shigella (96%). All cases with positive reactions by coproculture were confirmed by IIP. In the control group it were obtained by IIF 12 cases with positive reactions for enteropathogenic E. coli and 4 cases for Shigella, including two cases of mixed infection by E. coli 026/Sh. dysenteriae and E. coli 0124/Sh. dysenteriae. It was discussed the high sensitivity and specificity of the IIF when compared with the traditional methods, being suggested that IIF is a valuable tool in epidemiological studies involving these organisms and an important aid in the stablishment of an early presumptive diagnosis of the acute infantile diarrhea.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A clinical case is described in this paper in that a 5-month old baby girl severely malnourished and dehydrated presented a prolonged acute diarrhoea. No enteropathogenic bacteria or parasites were demonstrated. Virological study by electron microscopy (EM) showed that the patient shed both astrovirus-like and rotavirus in the watery stool as long as 12 days after the onset. Immune electron microscopy (IEM) performed with the patient serum revealed clumps of both viruses. It is suggest that this may be a case of mixed infection due to astrovirus-like and rotavirus.