6 resultados para Seismic recorder
em Scielo Saúde Pública - SP
Resumo:
In this paper we present a study of feasibility by using Cassino Parallel Manipulator (CaPaMan) as an earthquake simulator. We propose a suitable formulation to simulate the frequency, amplitude and acceleration magnitude of seismic motion by means of the movable platform motion by giving a suitable input motion. In this paper we have reported numerical simulations that simulate the three principal earthquake types for a seismic motion: one at the epicenter (having a vertical motion), another far from the epicenter (with the motion on a horizontal plane), and a combined general motion (with a vertical and horizontal motion).
Resumo:
AbstractBackground:The recording of arrhythmic events (AE) in renal transplant candidates (RTCs) undergoing dialysis is limited by conventional electrocardiography. However, continuous cardiac rhythm monitoring seems to be more appropriate due to automatic detection of arrhythmia, but this method has not been used.Objective:We aimed to investigate the incidence and predictors of AE in RTCs using an implantable loop recorder (ILR).Methods:A prospective observational study conducted from June 2009 to January 2011 included 100 consecutive ambulatory RTCs who underwent ILR and were followed-up for at least 1 year. Multivariate logistic regression was applied to define predictors of AE.Results:During a mean follow-up of 424 ± 127 days, AE could be detected in 98% of patients, and 92% had more than one type of arrhythmia, with most considered potentially not serious. Sustained atrial tachycardia and atrial fibrillation occurred in 7% and 13% of patients, respectively, and bradyarrhythmia and non-sustained or sustained ventricular tachycardia (VT) occurred in 25% and 57%, respectively. There were 18 deaths, of which 7 were sudden cardiac events: 3 bradyarrhythmias, 1 ventricular fibrillation, 1 myocardial infarction, and 2 undetermined. The presence of a long QTc (odds ratio [OR] = 7.28; 95% confidence interval [CI], 2.01–26.35; p = 0.002), and the duration of the PR interval (OR = 1.05; 95% CI, 1.02–1.08; p < 0.001) were independently associated with bradyarrhythmias. Left ventricular dilatation (LVD) was independently associated with non-sustained VT (OR = 2.83; 95% CI, 1.01–7.96; p = 0.041).Conclusions:In medium-term follow-up of RTCs, ILR helped detect a high incidence of AE, most of which did not have clinical relevance. The PR interval and presence of long QTc were predictive of bradyarrhythmias, whereas LVD was predictive of non-sustained VT.
Um chronographo de construção simples, permittindo registrar intervallos de tempo de 1 a 60 segundos
Resumo:
Descriptive memorial of a chronograph made from a common chronoscop (Eastman Timer). The chronoscop has been modified in order to permit to adjust distinct cog-wheels, everyone in its turn, to the axis of the seconds hand. Each of these cog-wheels holds a definite number of teeth accordingly with the time interval ones desire to record. A wheel with 20 teeth, for instance, is available for recording time in periods of each three seconds, another wheel with 6 teeth, will reckon time in intervals of 10 seconds and so on. These wheels may be interchanged most easily, which enables, with the same apparatus, to have at hand a time recorder for any time interval between one and sixty seconds. To register the time the apparatus is connected with a dry cell. A wire is attached to a binding post on the metal case of the apparatus, another wire being connected with an isolated binding post placed in front of the cog-wheel and fastened to a platinum point allowing open or shut the circuit, every time one of the cogs of the wheel comes into contact with this platinum point. A signal magnet is placed also in the circuit for writing the time intervals on the revolving drum.
Resumo:
Among the challenges of pig farming in today's competitive market, there is factor of the product traceability that ensures, among many points, animal welfare. Vocalization is a valuable tool to identify situations of stress in pigs, and it can be used in welfare records for traceability. The objective of this work was to identify stress in piglets using vocalization, calling this stress on three levels: no stress, moderate stress, and acute stress. An experiment was conducted on a commercial farm in the municipality of Holambra, São Paulo State , where vocalizations of twenty piglets were recorded during the castration procedure, and separated into two groups: without anesthesia and local anesthesia with lidocaine base. For the recording of acoustic signals, a unidirectional microphone was connected to a digital recorder, in which signals were digitized at a frequency of 44,100 Hz. For evaluation of sound signals, Praat® software was used, and different data mining algorithms were applied using Weka® software. The selection of attributes improved model accuracy, and the best attribute selection was used by applying Wrapper method, while the best classification algorithms were the k-NN and Naive Bayes. According to the results, it was possible to classify the level of stress in pigs through their vocalization.
Resumo:
In order to reach higher broiler performance, farmers target losses reduction. One way to make this possible is by rearing sexed broilers as male and female present diverse performance due to their physiological differences. Birds from different genetic strain also have a distinct performance at the same age. Considering that sexed flocks may present higher performance this study aimed to identify one-day-old chicks’ sex throughout their vocalization. This research also investigated the possibility of identifying the genetic strain by their vocalization attributes. A total of 120 chicks, half of them were from Cobb® genetic strain and the other half from Ross® genetic strain. From each group, a total of 30 were males and 30 females, which were previously separated by sex using their secondary physiological characteristics at the hatchery. Vocalizations audio recording was done inside a semi-anechoic chamber using a unidirectional microphone connected to an audio input of a digital recorder. Vocalizations were recorded for two minutes. Acoustic characteristics of the sounds were analyzed being calculated the fundamental frequency Pitch, the sound intensity, the first formant, and second formant. Results indicated that the vocalizations of both sexes could be identified by the second formant, and the genetic strain was detected by both the second formant and the Pitch.
Resumo:
OBJETIVO: avaliar a concordância dos diferentes parâmetros urodinâmicos comparados à cistometria simplificada, permitindo uma diminuição na relação custo-benefício no diagnóstico da incontinência urinária de esforço (IUE) na mulher. MÉTODOS: foram coletadas e avaliadas retrospectivamente as informações contidas dos prontuários de trinta pacientes acompanhadas, no período de janeiro de 2000 a março de 2001. Todas foram submetidas a exame físico geral e ginecológico. O estudo urodinâmico foi realizado pela técnica convencional, utilizando-se aparelho Dynograph Recorder R-611. A cistometria simplificada foi realizada com auxílio de um equipo em "Y" de PVC (pressão venosa central), conectado a um sonda de Foley 14 F, que permitia tanto a infusão de soro fisiológico como a captação da pressão intra-vesical. Foram analisados os parâmetros: volume residual, capacidade vesical, complacência, presença de contrações involuntárias do detrusor e perdas urinárias aos esforços. Para determinação da proporção de concordância entre os métodos foram utilizados o teste de concordância de Pearson e o teste de Wilcoxon, para amostras relacionadas. RESULTADOS: a média de idade foi de 50 anos, com extremos variando de 28 a 70 anos. O índice de concordância entre os estudos, na demonstração das perdas urinárias aos esforços, foi de 67%. Para a detecção das contrações involuntárias do detrusor, a proporção de concordância foi de 90%. A média do volume residual encontrado na cistometria simplificada foi de 16,8 ml contra 2 ml da urodinâmica convencional, com diferença significativa (p < 0,01). A média de capacidade vesical máxima no estudo urodinâmico foi de 440,5 ml, enquanto que, na cistometria simplificada, foi de 387 ml (p < 0,05). A complacência vesical foi, em média, significativamente maior na cistometria simplificada (43,0 ml/cmH2O) quando comparada ao estudo urodinâmico (31,5 ml/cmH2O), com p < 0,01. CONCLUSÃO: Avaliações preliminares sugerem que a propedêutica uroginecológica associada à cistometria simplificada é uma opção a ser considerada na avaliação clínica e pré-operatória de pacientes com IUE em substituição à urodinâmica convencional, particularmente onde esta última não se encontra disponível. A cistometria simplificada é um exame acessível que é capaz de detectar contrações involuntárias do detrusor, assim como identificar perdas urinárias com relativa sensibilidade, proporcionando ao examinador noções fidedignas do comportamento vesical.