14 resultados para Screen printed electrodes
em Scielo Saúde Pública - SP
Resumo:
Initially, all major factors that affect the rate of the AldH-catalyzed reaction (enzyme concentration, substrate concentration, temperature and pH) were investigated. Optimal activity was observed between pH values of 7.5 and 9.5 in the temperature range of 25 to 50 ºC. Kinetic parameters, such as Km (2.92 µmol L-1) and Vmax (1.33 10-2 µmol min-1) demonstrate a strong enzyme-substrate affinity. The sensors were based on screen-printed electrodes modified with the Meldola Blue-Reinecke salt (MBRS) combination. Operational conditions (NAD+ and substrate contents, enzyme loading and response time) were optimized. Also, two enzyme immobilization procedures were tested: entrapment in poly(vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ) and crosslinking with glutaraldehyde. Chronoamperometry was employed to observe the biosensor responses during enzymatic hydrolysis of propionaldehyde and also to construct inhibition curves with maneb and zineb fungicides. Best results were found with the following conditions: [NAD+] = 0.25 mmol L-1; [propionaldehyde] = 80 µmol L-1; enzyme loading = 0.8 U per electrode; response time = 10 min, and inhibition time = 10 min. Current intensities around 103 ± 13 nA with the sensors and good stability was obtained for both immobilization procedures. Detection limits, calculated using 10% inhibition were 31.5 µg L-1 and 35 µg L-1 for maneb and zineb, respectively. Results obtained with other MBRS-modified electrodes consisting of mono and bi-enzymic sensors were compared. The ability to catalyze NADH oxidation by MB was also highlighted.
Resumo:
This paper describes a comparative study between the procedures of deconvolution and the second-order derivative of square wave voltammograms to achieve separation of the voltammetric peaks of levofloxacin (LEVO) and norfloxacin (NOR), for their simultaneous quantification in urine samples. The obtained results indicate that the use of second-derivative voltammograms coupled with carbon screen-printed electrodes is the most efficient approach for completely separating the voltammetric peaks of LEVO and NOR. In addition, this approach has produced detection limits lower than 1.0 µmol L-1 and a wide linear range for both drugs. The proposed method was successfully used to simultaneously determine LEVO and NOR in spiked human and bovine urine samples with recovery percentages close to 100% for all analyzed samples.
Resumo:
A review dealing with the use of screen-printing technology to manufacture disposable electrodes is presented, covering in details virtually all the publications in the area up to early 1997 and including 206 references. The elements and different strategies on constructing modified electrodes are highlighted. Commercial and Home-made ink recipes are discussed. Microelectrode arrays, built by the combination of photostructuring and screen-printing technologies to the mass production of advanced disposable sensors, are also discussed. Future research trends are predicted.
Resumo:
INTRODUÇÃO: Programas de investigação epidemiológica e de ação no âmbito da violência familiar estão em franca ascensão, requerendo instrumentos de aferição adaptados e vertidos para o português. O objetivo do estudo é avaliar a equivalência semântica entre o original em inglês e duas versões para o português do instrumento Abuse Assessment Screen (AAS) usado no rastreamento de casos de violência contra a mulher grávida e recomendar uma versão-síntese para uso corrente. MÉTODOS: O processo de avaliação de equivalência semântica envolveu quatro etapas: tradução, retradução, apreciação formal de equivalência e crítica final através de consultas com especialista na área temática. RESULTADOS: Para cada item do instrumento apresentam-se os resultados relativos às quatro etapas. O texto cobre cada passo do processo que levou à versão final. As duas versões mostraram-se bastante semelhantes, com 14 das 15 assertivas similares, embora a segunda versão tenha se mostrado mais adequada, ainda que para alguns itens tenha sido decidido juntar as duas versões ou mesmo utilizar um item oriundo da versão um. CONCLUSÃO: É importante usar mais de uma versão no processo, em várias etapas de avaliação e de crítica, e discutir a pertinência de se acrescentar uma etapa adicional de interlocução do instrumento com membros da população-alvo.
Resumo:
PURPOSE: The Internet expands the range and flexibility of teaching options and enhances the ability to process the ever-increasing volume of medical knowledge. The aim of this study is to describe and discuss our experience with transforming a traditional medical training course into an Internet-based course. METHOD: Sixty-nine students were enrolled for a one-month course. They answered pre- and post-course questionnaires and took a multiple-choice test to evaluate the acquired knowledge. RESULTS: Students reported that the primary value for them of this Internet-based course was that they could choose the time of their class attendance (67%). The vast majority (94%) had a private computer and were used to visiting the Internet (75%) before the course. During the course, visits were mainly during the weekends (35%) and on the last week before the test (29%). Thirty-one percent reported that they could learn by reading only from the computer screen, without the necessity of printed material. Students were satisfied with this teaching method as evidenced by the 89% who reported enjoying the experience and the 88% who said they would enroll for another course via the Internet. The most positive aspect was freedom of scheduling, and the most negative was the lack of personal contact with the teacher. From the 80 multiple-choice questions, the mean of correct answers was 45.5, and of incorrect, 34.5. CONCLUSIONS: This study demonstrates that students can successfully learn with distance learning. It provides useful information for developing other Internet-based courses. The importance of this new tool for education in a large country like Brazil seems clear.
Resumo:
Simple double repetitive element polymerase chain reaction (MaDRE-PCR) and Pvu II-IS1245 restriction fragment length polymorphism (RFLP) typing methods were used to type 41 Mycobacterium avium isolates obtained from 14 Aids inpatients and 10 environment and animals specimens identified among 53 mycobacteria isolated from 237 food, chicken, and pig. All environmental and animals strains showed orphan patterns by both methods. By MaDRE-PCR four patients, with multiple isolates, showed different patterns, suggesting polyclonal infection that was confirmed by RFLP in two of them. This first evaluation of MaDRE-PCR on Brazilian M. avium strains demonstrated that the method seems to be useful as simple and less expensive typing method for screening genetic diversity in M. avium strains on selected epidemiological studies, although with limitation on analysis identical patterns except for one band.
Resumo:
The publishing industry is at a turning point. Facing the first major disruptive innovation in five centuries, its long-established structure and business model are at stake. Building on literature based on the pitfalls for incumbents, we interviewed key executives from the major publishers in Brazil to understand their perspective. We find that not only are they facing those pitfalls, but we also propose a new one, The Industry View Trap, concerning challenges created by convergence, the difficulty to deal with changes in the ecosystem and the fact that the very definition of the industry you're part of might have changed.
Resumo:
This study aimed to evaluate different proportions of organic compost and soil as a substrate for the guavira emergence and seedling formation under different protected environments, in the high Pantanal region of the state of Mato Grosso do Sul. The seeds were placed in polyethylene bags (15 x 25 centimeters) filled with four percentages of organic compost (0%, 20%, 80%, and 100% of total volume) mixed with soil. These substrates were tested in agro-nurseries covered with black screen and 50% thermo-reflecting shade cloths. The substrate with 20% soil and 80% organic compost and the black screen shade cloth promote the best performance in the seedling production.
Resumo:
This paper presents a review of the concepts involved in the working mechanism of the ion-selective electrodes, searching a historical overview, moreover to describe the new advances in the area.
Resumo:
Cyclic voltammetry was used to study 3,4-dihydroxybenzaldehyde (3,4-DHB) electropolymerization processes on carbon paste electrodes. The characteristics of the electropolymerized films were highly dependent on pH, anodic switching potential, scan rate, 3,4-DHB concentrations and number of cycles. Film stability was determined in citrate/phosphate buffer solutions at the same pH used during the electropolymerization process. The best conditions to prepare carbon paste modified electrodes were pH 7.8; 0.0 <= Eapl <= 0.25 V; 10 mV s-1; 0.25 mmol L-1 3,4-DHB and 10 scans. These carbon paste modified electrodes were used for NADH catalytic detection at 0.23 V in the range 0.015 <= [NADH] <= 0.21 mmol L-1. Experimental data were used to propose a mechanism for the 3,4--DHB electropolymerization processes, which involves initial phenoxyl radical formation.
Resumo:
The use of carbon paste electrodes (CPE) of mineral sulfides can be useful for electrochemical studies to overcome problems by using massive ones. Using CPE-chalcopyrite some variables were electrochemically evaluated. These variables were: (i) the atmosphere of preparation (air or argon) of CPE and elapsed time till its use; (ii) scan rate for voltammetric measurements and (iii) chalcopyrite concentration in the CPE. Based on cyclic voltammetry, open-circuit potential and electrochemical impedance results the recommendations are: oxygen-free atmosphere to prepare and kept the CPE until around two ours, scan rates from 10 to 40 mV s-1, and chalcopyrite concentrations > 20%.
Resumo:
An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level.
Resumo:
Some models of ion-selective electrodes (ISE) and other methods have been elaborated, to quantify nitrate levels in environmental samples (water, fruits, vegetables and others), using direct potentiometry
Resumo:
This work is directed to the study and evaluation of gas diffusion electrodes as detectors in hydrogen sensors. Electrochemical experiments were carried out with rotating disk electrodes with a thin porous coating of the catalyst as a previous step to select useful parameters for the sensor. An experimental arrangement made in the laboratory that simulates the sensor was found appropriate to detect volumetric hydrogen percentages above 0.25% in mixtures H2:N2. The system shows a linear response for volumetric percentages of hydrogen between 0.25 and 2 %.