99 resultados para Sample Preparation

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nickel, although essential to plants, may be toxic to plants and animals. It is mainly assimilated by food ingestion. However, information about the average levels of elements (including Ni) in edible vegetables from different regions is still scarce in Brazil. The objectives of this study were to: (a) evaluate and optimize a method for preparation of vegetable tissue samples for Ni determination; (b) optimize the analytical procedures for determination by Flame Atomic Absorption Spectrometry (FAAS) and by Electrothermal Atomic Absorption (ETAAS) in vegetable samples and (c) determine the Ni concentration in vegetables consumed in the cities of Lorena and Taubaté in the Vale do Paraíba, State of São Paulo, Brazil. By means of the analytical technique for determination by ETAAS or FAAS, the results were validated by the test of analyte addition and recovery. The most viable method tested for quantification of this element was HClO4-HNO3 wet digestion. All samples but carrot tissue collected in Lorena contained Ni levels above the permitted by the Brazilian Ministry of Health. The most disturbing results, requiring more detailed studies, were the Ni concentrations measured in carrot samples from Taubaté, where levels were five times higher than permitted by Brazilian regulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The goal of this work was to develop a simple and rapid preparation method for patulin analysis in apple juice without previous clean-up. This method combined sonication and liquid extraction techniques and was used for determination of patulin in 37 commercial apple juices available on the market in the South of Brazil. The method performance characteristics were determined using a sample obtained in a local market fortified at five concentration levels of patulin and done in triplicates. The coefficient of variation for repeatability at the fortification level of 20.70µg.L-1 was 3.53 % and the recovery 94.63 %, respectively. The correlation coefficient was 0.9996 and agrees with the requirements for a linear analytical method value. The detection limit was 0.21µg.L-1 and the quantification limit 0.70 µg.L-1. Only three of the analyzed samples were upper the allowed level of 50.00 µg.L-1 recommended for the World Health Organization.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Sample preparation and DNA extraction protocols for DNA amplification by PCR, which can be applied in human fecal samples for taeniasis diagnosis, are described. DNA extracted from fecal specimens with phenol/chloroform/isoamilic alcohol and DNAzol® reagent had to be first purified to generate fragments of 170 pb and 600 pb by HDP2-PCR. This purification step was not necessary with the use of QIAmp DNA stool mini kit®. Best DNA extraction results were achieved after eggs disruption with glass beads, either with phenol/chloroform/isoamilic alcohol, DNAzol® reagent or QIAmp DNA stool mini kit®.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sulfur in the soil occurs in two basic forms, organic and inorganic S. The organic form accounts for 95 % of S in most soils. The effectiveness of organic S to oxidate to sulfate was evaluated for total S determination in soil samples by wet (acid) and dry-ash (alkaline) oxidation methods. To evaluate the wet method and the possible use as a reference when evaluating the dry method proposed here, a reference standard from the US National Institute of Standards and Technology (NIST) was used (Montana Soil - NIST 2710). The dry-ash oxidation process with alkaline oxidizing agents is one of the simplest oxidation methods of organic S to the sulfate form and was compared with the wet process. The objective of the study was to develop a dry method that would be easy to apply and allow the complete conversion of organic S to sulfate in soil samples and later detection by turbidimetry. The effectiveness of organic S oxidation to sulfate was evaluated by means of three alkaline oxidation mixtures: NaHCO3 + Ag2O, Eschka mixture (17 % Na2CO3, 66 % MgO, and 17 % K2CO3), and NaHCO3 + CuO. The procedure to quantify the sulfate concentration was based on the reaction with barium chloride and turbidimetric detection. Sulfur quantification in the standard sample by the wet method proved adequate, precise and accurate. It should also be pointed out that no significant differences were found (95 % reliability) between the wet and dry processes (NaHCO3 and Ag2O oxidation mixture) in six different Brazilian soils. The proposed dry method can therefore be used in the preparation of soil samples for total S determination.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sulphur plays an essential role in plants and is one of the main nutrients in several metabolic processes. It has four stable isotopes (32S, 33S, 34S, and 36S) with a natural abundance of 95.00, 0.76, 4.22, and 0.014 in atom %, respectively. A method for isotopic determination of S by isotope-ratio mass spectrometry (IRMS) in soil samples is proposed. The procedure involves the oxidation of organic S to sulphate (S-SO4(2-)), which was determined by dry combustion with alkaline oxidizing agents. The total S-SO4(2-) concentration was determined by turbidimetry and the results showed that the conversion process was adequate. To produce gaseous SO2 gas, BaSO4 was thermally decomposed in a vacuum system at 900 ºC in the presence of NaPO3. The isotope determination of S (atom % 34S atoms) was carried out by isotope ratio mass spectrometry (IRMS). In this work, the labeled material (K2(34)SO4) was used to validate the method of isotopic determination of S; the results were precise and accurate, showing the viability of the proposed method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This review presents the latest advances of the mechanisation in sample preparation using microwave oven. The fundamental principles of microwaves field interaction with matter are presented, followed by the basic principles of microwave equipment construction. Hyphenation of microwave oven with flow injection analysis or robotic are discussed as well as some metodological difficulties and solutions by its implementation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Two models of a glass micro-extractor were constructed after modification of a model proposed in the literature. The two models were used for the simultaneous extraction and enrichment of organochlorinated pesticides from aqueous matrixes to an organic solution appropriate for the gas chromatographic analysis of the pesticide. It was established that the performance of one of the modified micro-extractors permits the pre-concentration of the pesticides to a level that allow their quantitation at the trace level with electron capture detection. It is thus concluded that the glass micro-extractor is a suitable tool for the sample preparation step in the gas chromatographic analysis of environmental pollutants of the class of pesticides.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The solution fluorescence of N-alkyl-2,3-naphthalimides (1-4) in polar protic and aprotic solvents was compared to the emission from solid samples resulting from the imide complexation with b-cyclodextrin or adsorption on the surface of microcrystalline cellulose. Solid samples of the inclusion complex 2,3-naphthalimides/b-cyclodextrin show maximum for fluorescence emission significantly different to the observed in methanolic solution. Beside this, a clear effect on the alkyl chain length could be observed for these samples which is probably due to differences in probe location inside the cyclodextrin cavity. The constancy for fluorescence quantum yield and fluorescence lifetime for the imides 1 - 4 adsorbed on microcrystalline cellulose suggests that, independently of the polarity of the solvent used for sample preparation, the probe is preferentially located on the cellulose surface. An increase of fluorescence quantum yield and fluorescence lifetime for solid samples, when compared to the values obtained in solution for the different solvents employed in this study (acetonitrile, methanol and water), is fully in accordance with a decrease of the probe mobility due to inclusion in b-cyclodextrin or to adsorption on cellulose.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aspects related to the quality of human hair analysis are presented, such as sample collection, sample preparation, determination of trace elements and application examples. Also the hair morphology, the importance of this analysis and its uses and meanings are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work discusses sample preparation processes for gas chromatography (GC) based on the technique of extraction through membrane permeation (MPE). The MPE technique may be easily coupled to GC via a relatively simple device, which is a module that holds the membrane and is directly connected to the GC column. The possibility of operational errors due to sample handling is substantially reduced in an MPE-GC system because the sample preparation and the chemical analysis are accomplished as a one-step process. The MPE technique is of relatively wide application as it can be used for aqueous samples, solid samples and gaseous samples. Depending on the type of sample the extraction is performed with the membrane in direct contact with the sample or in contact with its headspace. The MPE-GC technique is very useful in trace analysis, due to the time-dependent enrichment of the analyte. A typical application of MPE-GC is the analysis of VOCs present in water that may be accomplished with detection limits at the low ppb (mugL-1) level.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Anodic electrodissolution procedure in a flow injection system for determination of constituents in alloys is discussed. This approach implement sample preparation procedure by using a chamber and a DC power supply with constant direct current. Solid sample was attached to chamber as anode. In this review a general overview of these procedure is presented. The procedure presented a good performance characterized by a high sample throughput determinations, good accuracy and relative standard deviation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundamental aspects of Solid Phase Micro-Extraction (SPME) are discussed in the present paper. The application of SPME as a microtechnique of sample preparation for gas chromatographic analysis is considered and related to existing theoretical models. Both research prototypes and commercial SPME devices are considered.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

When organic compounds present in biological fluids are analysed by chromatographic methods, it is generally necessary to carry out a prior sample preparation due the high complexity of this type of sample, especially when the compounds to be determinated are found in very low concentrations. This article describes some of the principal methods for sample preparation in analyses of substances present in biological fluids. The methods include liquid-liquid extraction, solid phase extraction, supercritical fluid extraction and extraction using solid and liquid membranes. The advantages and disadvantages of these methods are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Calculation of uncertainty of results represents the new paradigm in the area of the quality of measurements in laboratories. The guidance on the Expression of Uncertainty in Measurement of the ISO / International Organization for Standardization assumes that the analyst is being asked to give a parameter that characterizes the range of the values that could reasonably be associated with the result of the measurement. In practice, the uncertainty of the analytical result may arise from many possible sources: sampling, sample preparation, matrix effects, equipments, standards and reference materials, among others. This paper suggests a procedure for calculation of uncertainties components of an analytical result due to sample preparation (uncertainty of weights and volumetric equipment) and instrument analytical signal (calibration uncertainty). A numerical example is carefully explained based on measurements obtained for cadmium determination by flame atomic absorption spectrophotometry. Results obtained for components of total uncertainty showed that the main contribution to the analytical result was the calibration procedure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Materials obtained during the synthesis of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) were characterized by Fourier transform infrared (FTIR) transmission spectroscopy and/or Fourier transform infrared photoacoustic spectroscopy (FTIR-PAS). By these techniques the spectrometric alterations that occurred during the process were observed. The characterized species during the synthesis of HMX were alpha-HMX, beta-HMX, hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and HMX/RDX mixtures. The FTIR-PAS was verified to be a promising technique of great usefulness of the characterization of highly energetic materials because it is fast, simple and requires no sample preparation unlike Fourier transform infrared transmission technique (KBr pellet). The FTIR-PAS analysis showed that with small sample quantity is possible to distinguish between thealpha-HMX and beta-HMX and to detect even in a qualitative way different HMX / RDX ratios.