236 resultados para SIMPLE ASSAY

em Scielo Saúde Pública - SP


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A simple method of rubella antigen production by treatment with sodium desoxycholate for use in enzyme immunoassay (IMT-ELISA) is presented. When this assay was compared with a commercial test (Enzygnost-Rubella, Behring), in the study of 108 sera and 118 filter paper blood samples, 96.9% (219/226) overall agreement and correlation coefficient of 0.90 between absorbances were observed. Seven samples showed discordant results, negative by the commercial kit and positive by our test. Four of those 7 samples were available, being 3 positive by HI.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Studies were done to evaluate comparatively the traditional HA assay and a more recently introduced lectin-neuraminidase (LN) methodologyin search of a simple and sensitive assay for virus detection during laboratorial diagnosis. The results proved the value of LN assay as a sensitive methodologyfor detection of virus particles, presenting results at least equal to those obtained by HA (hemagglutination) assay, with significant values of accumulated frequencies for LN/HA factors (ratios between LN and HA titers) higher than two. The accumulated values of frequencies for LN/HA factors as high as four were very significant, 72.7 (per cent) for influenzavirus and 60.7 (per cent) for Newcastle disease virus (NDV), moreover accumulated frequencies for LN/HA factors even as high as 32 were due to influenzavirus (45.4 per cent) and NDV (7.2 per cent) samples. After the storage period, most of those concentraded samples that even did not present HA titers could be detected through LN assay, demonstrating a lower threshold for virus detection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work reports the validation of an analytical UV spectrophotometric method to assay dexamethasone in tablets (assay and dissolution studies). The method was linear in the range between 1 and 30 µg mL-1 presenting a good correlation coefficient (r = 0.9998, n = 7). Precision and accuracy analysis showed low relative standard deviation (< 2.00%) and good percentual recoveries (95-105%). The procedure was linear, accurate, precise, and robust. The method is simple, and it has low cost. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay dexamethasone in tablets.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To assess the clinical relevance of a semi-quantitative measurement of human cytomegalovirus (HCMV) DNA in renal transplant recipients within the typical clinical context of a developing country where virtually 100% of both receptors and donors are seropositive for this virus, we have undertaken HCMV DNA quantification using a simple, semi-quantitative, limiting dilution polymerase chain reaction (PCR). We evaluated this assay prospectively in 52 renal transplant patients from whom a total of 495 serial blood samples were collected. The samples scored HCMV positive by qualitative PCR had the levels of HCMV DNA determined by end-point dilution-PCR. All patients were HCMV DNA positive during the monitoring period and a diagnosis of symptomatic infection was made for 4 of 52 patients. In symptomatic patients the geometric mean of the highest level of HCMV DNAemia was 152,000 copies per 106 leukocytes, while for the asymptomatic group this value was 12,050. Symptomatic patients showed high, protracted HCMV DNA levels, whereas asymptomatic patients demonstrated intermittent low or moderate levels. Using a cut-off value of 100,000 copies per 106 leukocytes, the limiting dilution assay had sensitivity of 100%, specificity of 92%, a positive predictive value of 43% and a negative predictive value of 100% for HCMV disease. In this patient group, there was universal HCMV infection but relatively infrequent symptomatic HCMV disease. The two patient groups were readily distinguished by monitoring with the limiting dilution assay, an extremely simple technology immediately applicable in any clinical laboratory with PCR capability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Faeces of 138 chickens were inoculated on Blaser agar plates. One set of plates was incubated in jars with CampyPak envelopes. The others were incubated in "Zip-lock" plastic bags (7 x X in.) and a microaerophilic atmosphere was generated exhaling into the "Zip-lock" plastic bag, after holding the breath for 20 sec. Then, the bag was pressed to evacuate its atmosphere, inflated again, and pressed (4 times), and finally sealed. Campylobacter was isolated from 127 (96.2%) of samples incubated in jars with gas generator envelopes and from 129 (98%) of the specimens incubated into the bags. The proposed methodology offers good savings for cost-conscious laboratories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract: INTRODUCTION : Molecular analyses are auxiliary tools for detecting Koch's bacilli in clinical specimens from patients with suspected tuberculosis (TB). However, there are still no efficient diagnostic tests that combine high sensitivity and specificity and yield rapid results in the detection of TB. This study evaluated single-tube nested polymerase chain reaction (STNPCR) as a molecular diagnostic test with low risk of cross contamination for detecting Mycobacterium tuberculosis in clinical samples. METHODS: Mycobacterium tuberculosis deoxyribonucleic acid (DNA) was detected in blood and urine samples by STNPCR followed by agarose gel electrophoresis. In this system, reaction tubes were not opened between the two stages of PCR (simple and nested). RESULTS: STNPCR demonstrated good accuracy in clinical samples with no cross contamination between microtubes. Sensitivity in blood and urine, analyzed in parallel, was 35%-62% for pulmonary and 41%-72% for extrapulmonary TB. The specificity of STNPCR was 100% in most analyses, depending on the type of clinical sample (blood or urine) and clinical form of disease (pulmonary or extrapulmonary). CONCLUSIONS: STNPCR was effective in detecting TB, especially the extrapulmonary form for which sensitivity was higher, and had the advantage of less invasive sample collection from patients for whom a spontaneous sputum sample was unavailable. With low risk of cross contamination, the STNPCR can be used as an adjunct to conventional methods for diagnosing TB.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a simple method for evaluating the binding of concanavalin A (ConA) to human peripheral blood mononuclear cells (PBMC). The binding is evidenced by an immunoenzymic assay using peroxidase-conjugated immunoglobulins of a rabbit anti-ConA serum. Using the method we show that sera from patients with American leishmaniasis do not interfere with binding of ConA to PBMC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A slide micro-immunoenzymatic assay (micro-SIA) to detectantibodies to non-particulate Toxoplasma gondii antigens is described. This assay allows the diagnosis of toxoplasmosis infection in about 1 hr. Twenty-four determinations can be performed per slide. Five hundred ng of antigen and 5 or 10 µl drop of each reactive are necessary per well. The clear contrast of colours obtained for negative and positive sera after the test is finished, allows direct discrimination of the results. However, it is possible to quantify the results of the reaction using a minireader. Sera dilution cutoff value, determined as themost frequent titre for the general population, is 1:100. The toxoplasma micro-SIA correlates well with indirect immunofluorescence (IIF), its sensitivity is atleast three times as much as IIF. The test has an intra and inter assay variation coefficient of 5.46 per cent and of 6.24 per cent respectively. Sera obtained at random from argentinian people were analyzed and a 56 per cent of infection was found. The main features of the Toxoplasma micro-SIA are its simplicity, sensitivity, reproducibility, and the virtual absence of background making it very suitable for screening tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We show here a simplified reverse transcription-polymerase chain reaction (RT-PCR) for identification of dengue type 2 virus. Three dengue type 2 virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD, as a negative control, were used in this study. C6/36 cells were infected with the virus, and tissue culture fluids were collected after 7 days of infection period. The RT-PCR, a combination of RT and PCR done after a single addition of reagents in a single reaction vessel was carried out following a digestion of virus with 1% Nonidet P-40. The 50ml assay reaction mixture included 50 pmol of a dengue type 2 specific primer pair amplifying a 210 base pair sequence of the envelope protein gene, 0.1 mM of the four deoxynucleoside triphosphates, 7.5U of reverse transcriptase, and 1U of thermostable Taq DNA polymerase. The reagent mixture was incubated for 15 min at 37oC for RT followed by a variable amount of cycles of two-step PCR amplification (92oC for 60 sec, 53oC for 60 sec) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized with UV light after gel incubation in ethidium bromide solution. DNA bands were observed after 25 and 30 cycles of PCR. Virus amount as low as 102.8 TCID50/ml was detected by RT-PCR. Specific DNA amplification was observed with the three dengue type 2 strains. This assay has advantages compared to other RT-PCRs: it avoids laborious extraction of virus RNA; the combination of RT and PCR reduces assay time, facilitates the performance and reduces risk of contamination; the two-step PCR cycle produces a clear DNA amplification, saves assay time and simplifies the technique

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A dot enzyme-linked immunosorbent assay (dot-ELISA) was standardized using excretory-secretory antigens of Toxocara canis for the rapid immunodiagnosis of human toxocariasis. Thirty patients with clinical signs of toxocariasis, 20 cases with other parasitic diseases, and 40 healthy subjects were tested. A total of 0.2 ng of antigen per dot, serum dilution of 1:160 and dilution conjugate of 1:1000 were found optimal. The sensitivity and specificity of the assay were 100 and 95%, respectively. Comparable sensitivity of dot-ELISA and the standard ELISA was obtained, but only 3 cross-reactions occurred in the dot-ELISA, compared with 6 in the standard ELISA. Dot-ELISA is simple to perform, rapid, and low cost. Large-scale screening studies should be done to evaluate its usefulness under field conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We conducted a cross-sectional, hospital-based study between January 2006-March 2008 to estimate the resistance of Mycobacterium tuberculosis to first-line drugs in patients with tuberculosis at a Brazilian hospital. We evaluated the performance of the [3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-tetrazolium bromide] (MTT) microplate assay compared with the Bactec-MGIT 960™ system for mycobacteria testing. The prevalence of resistance in M. tuberculosis was 6.7%. Multidrug-resistance [resistance to rifampicin (RMP) and isoniazid (INH)], INH-resistance and streptomycin (SM)-resistance accounted for 1%, 3.8% and 3.8% of all resistance, respectively, and all isolates were susceptible to ethambutol (EM). The resistance was primary in four cases and acquired in three cases and previous treatment was associated with resistance (p = 0.0129). Among the 119 M. tuberculosis isolates, complete concordance of the results for INH and EM was observed between the MTT microplate and Bactec-MGIT 960TM methods. The observed agreement for RMP was 99% (sensitivity: 90%) and 95.8% for SM (sensitivity 90.9%), lower than those for other drugs. The MTT colourimetric method is an accurate, simple and low-cost alternative in settings with limited resources.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to investigate the performance of a new and accurate method for the detection of isoniazid (INH) and rifampicin (RIF) resistance among Mycobacterium tuberculosis isolates using a crystal violet decolourisation assay (CVDA). Fifty-five M. tuberculosis isolates obtained from culture stocks stored at -80ºC were tested. After bacterial inoculation, the samples were incubated at 37ºC for seven days and 100 µL of CV (25 mg/L stock solution) was then added to the control and sample tubes. The tubes were incubated for an additional 24-48 h. CV (blue/purple) was decolourised in the presence of bacterial growth; thus, if CV lost its colour in a sample containing a drug, the tested isolate was reported as resistant. The sensitivity, specificity, positive predictive value, negative predictive value and agreement for INH were 92.5%, 96.4%, 96.1%, 93.1% and 94.5%, respectively, and 88.8%, 100%, 100%, 94.8% and 96.3%, respectively, for RIF. The results were obtained within eight-nine days. This study shows that CVDA is an effective method to detect M. tuberculosis resistance to INH and RIF in developing countries. This method is rapid, simple and inexpensive. Nonetheless, further studies are necessary before routine laboratory implementation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A reversed-phase liquid chromatographic (LC) and ultraviolet (UV) spectrophotometric methods were developed and validated for the assay of bromopride in oral and injectable solutions. The methods were validated according to ICH guideline. Both methods were linear in the range between 5-25 μg mL-1 (y = 41837x - 5103.4, r = 0.9996 and y = 0.0284x - 0.0351, r = 1, respectively). The statistical analysis showed no significant difference between the results obtained by the two methods. The proposed methods were found to be simple, rapid, precise, accurate, and sensitive. The LC and UV methods can be used in the routine quantitative analysis of bromopride in oral and injectable solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid, economical, reproducible, and simple direct spectrophotometric method was developed and validated for the assay of nitazoxanide in pharmaceutical formulations. Nitazoxanide concentration was estimated in water at 345 nm and pH 4.5. The method was suitable and validated for specificity, linearity, precision, and accuracy. There was no interference of the excipients in the determination of the active pharmaceutical ingredient. The proposed method was successfully applied in the determination of nitazoxanide in coated tablets and in powders for oral suspension. This method was compared to a previously developed and validated method for liquid chromatography to the same drug. There was no significative difference between these methods for nitazoxanide quantitation.