Resumo:
Foram realizados o estudo morfométrico e o estudo hemodinâmico da veia porta em vinte cães clinicamente normais, de idade igual e inferior a 120 dias e em quatorze cães portadores de shunt portossistêmico, de idades entre 90 e 360 dias. Nos cães do grupo controle, as margens hepáticas apresentaram-se entre 1,50cm e 3,00cm caudalmente à margem costal. Os diâmetros médios da veia porta (VP), veia cava caudal (VCC) e aorta abdominal (AO) obtidas foram respectivamente, 0,38cm, 0,37cm e 0,41cm. As proporções entre os diâmetros médios VP/VCC e VP/AO apresentaram médias de 1,10 e 0,94, respectivamente. As médias das áreas da VP, VCC e AO resultaram respectivamente em 0,12cm² , 0,11cm² e 0,14cm². No estudo hemodinâmico da VP destes animais, utilizando-se o ultrassom Doppler, a velocidade média de fluxo sangüíneo portal (VMFSP) mediu 17,76cm/s. A média de fluxo sangüíneo portal (FSP) resultou em 83,11ml/min/kg. O índice de congestão (IC) apresentou média de 0,006. Para o grupo de cães portadores de shunt portossistêmico, o fígado apresentou redução de seu volume, sendo as margens hepáticas visibilizadas entre 1,00cm e 2,00cm cranialmente à margem costal. No estudo morfométrico, as médias dos diâmetros médios obtidos de VP, VCC e AO resultaram respectivamente em 0,40cm, 0,74cm e 0,56cm. As proporções entre os diâmetros médios VP/VCC e VP/AO resultaram respectivamente em 0,54 e 0,69. As médias das áreas de VP, VCC e AO resultaram respectivamente em 0,14cm², 0,31cm² e 0,25cm². Ao ultrassom Doppler a VMFSP mediu 22,29cm/s e a média do IC da VP obtido foi de 0,006.
Resumo:
OBJETIVOS: Descrever o uso do "shunt" intra-hepático portossistêmico (TIPS) e do "stent" venoso supra-hepático no manejo da síndrome de Budd-Chiari, enfocando suas indicações, aspectos técnicos e benefícios do procedimento. MATERIAIS E MÉTODOS: De janeiro de 1999 a março de 2002, nove casos de síndrome de Budd-Chiari foram encaminhados ao Serviço de Hemodinâmica do Hospital São Lucas, Porto Alegre, RS. A obstrução venosa supra-hepática foi constatada em todos os casos por meio de ultra-sonografia com Doppler em cores. A criação de TIPS foi realizada entre o sistema venoso supra-hepático ou a veia cava inferior e a veia porta, posicionando-se a endoprótese entre as duas abordagens. Doppler em cores pós-procedimento foi efetuado em todos os pacientes em períodos seriados. RESULTADOS: Três casos foram tratados inicialmente com inserção de "stent" venoso por apresentarem estenose preponderante em veias supra-hepáticas. Em dois desses casos ocorreu trombose do "stent", sendo necessária colocação de TIPS. Os demais seis casos foram tratados primariamente com TIPS. Dos oito "shunts" criados, trombose da endoprótese foi constatada em três casos, resolvidas com limpeza dos trombos e dilatação com balão em um caso e inserção de novas próteses nos demais. Embolização com molas de colaterais venosas ectasiadas foi efetuada em um paciente. CONCLUSÕES: A colocação de TIPS constitui-se numa estratégia terapêutica segura e efetiva na síndrome de Budd-Chiari, promovendo uma significativa melhora clínica e hemodinâmica dos pacientes, evitando procedimentos mais invasivos e podendo, em casos sem cirrose estabelecida, servir de tratamento definitivo da hipertensão portal.
Resumo:
OBJETIVO: Estudar os índices de impedância - índices de resistência (IR) e pulsatilidade (IP) - da artéria esplênica em pacientes com hepatopatia crônica. MATERIAIS E MÉTODOS: Foram estudados, prospectivamente, 42 pacientes com cirrose hepática e 21 pacientes com hepatite crônica. RESULTADOS: Foi observado que, nos pacientes com cirrose, ambos os índices estiveram elevados (IR = 0,63 ± 0,08 e IP = 1,02 ± 0,22) em comparação com os pacientes com hepatite crônica (IR = 0,58 ± 0,06 e IP = 0,89 ± 0,15) e os indivíduos do grupo controle (IR = 0,57 ± 0,04 e IP = 0,87 ± 0,11). Os cirróticos com evidência de circulação colateral à ultra-sonografia apresentaram, no entanto, menores índices de resistência (IR = 0,60 ± 0,08) em comparação com os cirróticos sem circulação colateral (IR = 0,65 ± 0,07), possivelmente devido ao shunt portossistêmico provocado pelos vasos colaterais. Não houve diferença significativa dos índices entre pacientes com e sem varizes esofagianas. CONCLUSÃO: O trabalho demonstrou que os índices de impedância da artéria esplênica podem ser úteis na avaliação de pacientes com hepatopatia crônica e hipertensão portal, contribuindo com dados adicionais à ultra-sonografia com eco-Doppler colorido.
Resumo:
Este artigo descreve um paciente que se apresentou com quadro de hipoxemia e platipnéia e cujo único achado na investigação foi a presença de um forame oval patente com shunt direita-esquerda sem hipertensão pulmonar, caracterizando uma síndrome rara conhecida como platipnéia-ortodeoxia, de interessantes características fisiopatológicas e com opções terapêuticas ainda não totalmente definidas.
Resumo:
Define-se a hipertensão porta pela presença de um gradiente de pressão venosa hepática superior a 5mmHg. Ela é causada geralmente pelo aumento da resistência do leito vascular porta-hepático em decorrência de obstrução ao fluxo sanguíneo. Nas formas graves da esquistossomose há aumento progressivo da pressão porta e o desenvolvimento de varizes nos órgãos intra-abdominais, no retroperitônio e na parede do abdômen. A principal complicação desse processo é o sangramento digestivo, proveniente, na maioria dos casos, das varizes esofágicas e gástricas. Para o tratamento, diversos procedimentos clínicos (propranolol, somatostatina e octeotrida), endoscópicos (escleroterapia, clipes e ligaduras de varizes), vasculares (TIPS - shunt intra-hepático transjugular portasistêmico) e cirúrgicos (derivações portassistêmicas e desconexões portavarizes) têm sido propostos. Neste artigo, o autor apresenta revisão crítica sobre os vários tratamentos propostos, enfatizando os procedimentos cirúrgicos.
Resumo:
The size of gastroesophageal varices is one of the most important factors leading to hemorrhage related to portal hypertension. An endoscopic evaluation of the size of gastroesophageal varices before and after different operations for portal hypertension was performed in 73 patients with schistosomiasis, as part of a randomized trial: proximal splenorenal shunt (PSS n=24), distal splenorenal shunt (DSS n=24), and esophagogastric devascularization with splenectomy (EGDS n=25). The endoscopic evaluation was performed before and up to 10 years after the operations. Variceal size was graded according to Palmer's classification: grade 1 -- up to 3 mm, grade 2 -- from 3 to 6 mm, grade 3 -- greater than 6 mm, and were analyzed in four anatomical locations: inferior, middle or superior third of the esophagus, and proximal stomach. The total number of points in the pre-operative grading minus the number of points in the post-operative grading gave a differential grading, allowing statistical comparison among the surgical groups. Good results, in terms of disappearance or decrease of variceal size, were observed more frequently after PSS than after DSS or EGDS - 95.8%, 83.3%, and 72%, respectively. When differential grading was analyzed, a statistically significant difference was observed between PSS and EGDS, but not between proximal and distal splenorenal shunts. In conclusion, shunt surgeries were more efficient than devascularization in diminishing variceal size.
Resumo:
Relatamos um caso raro de um paciente de 21 meses, portador de comunicação interatrial do tipo seio coronário, associada a comunicação interventricular perimembranosa, e ausência de veia cava superior esquerda. O diagnóstico foi realizado através da ecocardiografia e confirmado pela angiografia. O paciente foi operado sem intercorrências, ambos os defeitos foram fechados com patch de pericárdio bovino e o fluxo das veias coronárias ficou direcionado para o átrio esquerdo. Um ecocardiograma mostrou ausência de shunt residual através dos defeitos.
Resumo:
OBJETIVO: Avaliar a experiência global da nossa instituição com o fechamento percutâneo do canal arterial. MÉTODOS: Desde dezembro/92, 150 pacientes foram submetidos a 178 procedimentos (85 - técnica de Rashkind; 87 - coils de Gianturco; 6 - coils Duct Occlud). A mediana de idade foi de 6,5 anos (1 a 57). A média do diâmetro mínimo do canal foi de 3,05±1,24mm (1 a 8). Avaliações clínicas e ecocardiográficas foram realizadas seriadamente. RESULTADOS: Implantes adequados ocorreram em 143 (95,3%) pacientes. A prevalência de shunt residual imediato foi de 52,1%, decrescendo para 15,9% no seguimento. Esta taxa caiu para 5,2% após a realização de procedimentos adicionais. Embolização de coils ocorreu em 12 procedimentos e de umbrella em 1. Um paciente apresentou hemólise e outro estenose discreta da artéria pulmonar esquerda. Não houve mortalidade. CONCLUSÃO: Esta modalidade terapêutica é segura e eficaz, proporcionando bons resultados a longo prazo.
Resumo:
PURPOSE: Evaluation of the role of transesophageal echocardiography in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. METHODS: Patients were selected for percutaneous closure of ASD by transesophageal echocardiography (TEE), which was also used to monitor the procedure, helping to select the appropriate size of the Amplatzer device, to verify its position, and to access the immediate results of the procedure. During the follow-up, TEE was used to evaluate the presence and magnitude of residual shunt (RS), device position, and right cardiac chamber diameters. RESULTS: Twenty-two (40%) of a total of 55 studied patients were selected. Thirteen underwent Amplatzer device implantation, eight are still waiting for it, and one preferred the conventional surgical treatment. All procedures were successful, which was mainly due to proper patient selection. Six (23%) patients acutely developed RS, which spontaneously disapeared at the three-month follow-up examination in three patients. There was a significant reduction in the right ventricle diastolic diameter, from 27mm (average) to 24mm and 20mm, one and three months after the procedure, respectively (p<0.0076). CONCLUSION: With the aid of TEE, percutaneous closure of ASD can be successfully, safely, and effectively performed.
Resumo:
OBJETIVE: To assess the hemodynamic profile of cardiac surgery patients with circulatory instability in the early postoperative period (POP). METHODS: Over a two-year period, 306 patients underwent cardiac surgery. Thirty had hemodynamic instability in the early POP and were monitored with the Swan-Ganz catheter. The following parameters were evaluated: cardiac index (CI), systemic and pulmonary vascular resistance, pulmonary shunt, central venous pressure (CVP), pulmonary capillary wedge pressure (PCWP), oxygen delivery and consumption, use of vasoactive drugs and of circulatory support. RESULTS: Twenty patients had low cardiac index (CI), and 10 had normal or high CI. Systemic vascular resistance was decreased in 11 patients. There was no correlation between oxygen delivery (DO2) and consumption (VO2), p=0.42, and no correlation between CVP and PCWP, p=0.065. Pulmonary vascular resistance was decreased in 15 patients and the pulmonary shunt was increased in 19. Two patients with CI < 2L/min/m² received circulatory support. CONCLUSION: Patients in the POP of cardiac surgery frequently have a mixed shock due to the systemic inflammatory response syndrome (SIRS). Therefore, invasive hemodynamic monitoring is useful in handling blood volume, choice of vasoactive drugs, and indication for circulatory support.
Resumo:
We report new percutaneous techniques for perforating the pulmonary valve in pulmonary atresia with intact ventricular septum, in 3 newborns who had this birth defect. There was mild to moderate hypoplastic right ventricle, a patent infundibulum, and no coronary-cavitary communications. We succeeded in all cases, and no complications related to the procedure occurred. The new coaxial radiofrequency system was easy to handle, which simplified the procedure. Two patients required an additional source of pulmonary flow (Blalock-Taussig shunt) in the first week after catheterization. All patients had a satisfactory short-term clinical evolution and will undergo recatheterization within 1 year to define the next therapeutic strategy. We conclude that this technique may be safely and efficiently performed, especially when the new coaxial radiofrequency system is used, and it may become the initial treatment of choice in select neonates with pulmonary atresia and intact ventricular septum.