10 resultados para SAMPLERS

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Soil solution samplers may have the same working principle, but they differ in relation to chemical and physical characteristics, cost and handling, and these aspects exert influence on the chemical composition of the soil solution obtained. This study was carried out to evaluate, over time, the chemical composition of solutions extracted by Suolo Acqua, with the hydrophilic membrane (HM) as a standard, using soils with contrasting characteristics, and to determine the relationship between electrical conductivity (EC) and concentration of ions and pH of soil solution samples. This study was carried out under laboratory conditions, using three soils samples with different clay and organic matter (OM) contents. Soil solution contents of F−, Cl−, NO−3, Br−, SO42−, Na+, NH4+, K+, Mg2+, Ca2+, were analyzed, as well as inorganic, organic, and total C contents, pH, and EC, in four successive sampling times. Soil solution chemical composition extracted by the Suolo Acqua sampler is similar to that collected by the HM, but the Suolo Acqua extracted more Na+ and soluble organic C than the HM solution. Solution EC, cation and anion concentrations, and soluble C levels are higher in the soil with greater clay and OM contents (Latossolo and Cambissolo in this case). Soil solution composition varied over time, with considerable changes in pH, EC, and nutrient concentrations, especially associated with soil OM. Thus, single and isolated sampling of the soil solution must be avoided, otherwise composition of the soil solution may not be correctly evaluated. Soil solution EC was regulated by pH, as well as the sum of cation and anion concentrations, and the C contents determined in the soil liquid phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a methodology to predict benzene uptake rate in ambient air, using passive samplers with Tenax TA. Variations in the uptake rate were found to occur as a function of the sampling time; and were greater at the beginning of sampling. An empirical model was obtained and values for uptake rate agree with literature. Concentration prediction errors can be minimized by using sampling times of 4 to 14 days, thus avoiding the influence of excessive uptake rates in the initial days and the influence of back diffusion at the end of the sampling period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many studies have attempted to evaluate the importance of airborne fungi in the development of invasive fungal infection, especially for immunocompromised hosts. Several kinds of instruments are available to quantitate fungal propagule levels in air. We compared the performance of the most frequently used air sampler, the Andersen sampler with six stages, with a portable one, the Reuter centrifugal sampler (RCS). A total of 84 samples were analyzed, 42 with each sampler. Twenty-eight different fungal genera were identified in samples analyzed with the Andersen instrument. In samples obtained with the RCS only seven different fungal genera were identified. The three most frequently isolated genera in samples analyzed with both devices were Penicillium, Aspergillus and Cladophialophora. In areas supplied with a high efficiency particulate air filter, fungal spore levels were usually lower when compared to areas without these filters. There was a significant correlation between total fungal propagule measurements taken with both devices on each sampling occasion (Pearson coefficient = 0.50). However, the Andersen device recovered a broader spectrum of fungi. We conclude that the RCS can be used for quantitative estimates of airborne microbiological concentrations. For qualitative studies, however, this device cannot be recommended.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study it was compared the MAS-100 and the Andersen air samplers' performances and a similar trend in both instruments was observed. It was also evaluated the microbial contamination levels in 3060 samples of offices, hospitals, industries, and shopping centers, in the period of 1998 to 2002, in Rio de Janeiro city. Considering each environment, 94.3 to 99.4% of the samples were the allowed limit in Brazil (750 CFU/m³). The industries' results showed more important similarity among fungi and total heterotrophs distributions, with the majority of the results between zero and 100 CFU/m³. The offices' results showed dispersion around 300 CFU/m³. The hospitals' results presented the same trend, with an average of 200 CFU/m³. Shopping centers' environments showed an average of 300 CFU/m³ for fungi, but presented a larger dispersion pattern for the total heterotrophs, with the highest average (1000 CFU/m³). It was also investigated the correlation of the sampling period with the number of airborne microorganisms and with the environmental parameters (temperature and air humidity) through the principal components analysis. All indoor air samples distributions were very similar. The temperature and air humidity had no significant influence on the samples dispersion patterns.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims at the study of the air quality determination regarding the total suspended particles (TSP) and the associated metals in the counties of Charqueadas and Sapucaia do Sul at the state of Rio Grande do Sul. The TSP samples were collected using high volume samplers and the analysis of the metallic elements was accomplished through ICP-AES. The results revealed that the TSP concentrations, found in the two studied regions, have exceded the current air quality patterns established by the Brazilian Legislation. They also revealed high levels of several of the elements being attributed to the presence of anthropogenic sources. The correlation between meteorological data (speed and wind direction) and TSP concentrations were significant and revealed strong influence in particle dispersion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The passive sampling technique has been widely used for many years in the measurement of personal exposure to pollutantes in the workplace. In recent years the technique has been used too for measurements in ambient air. In the specific case of SO2 a variety of passive samplers have been described in the literature. The great number are diffusive samplers and some few are permeation samplers. They are basically of two types: badge and tube-type. However there are more than 10 variations in relation to the sampler dimensions, diffusion barriers and pollutant sorption medium. The technique trend to be very used in the near future with samplers able to reach very low detection limits, proposing a viable option for monitoring specific species at urban, regional and global scales.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main purpose of the present work is to study the concentration of atmospheric particles (PM10 and PM2.5) in the Candiota (RS) region using HV PM10 and dichotomous samplers. Four sampling sites at a distance of 50 km from the emission source were selected: Aceguá, Aeroporto, 8 de Agosto and Pedras Altas. Samples were collected from December 2000 to December 2001. The values obtained with the ISCST (Industrial Source Complex Term) model and with the samplers were compared on January 21st, April 5th, July 14th, August 1st, and October 13th 2001, and are representative of frontal systems occurring in the study area.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study is a result of undergraduate student participation in the Environmental Chemistry discipline provided by the Chemistry Institute/UFBA. The students were involved in the development of passive samplers, a project of the LAQUAM (Environmental Analytical Chemistry Laboratory). The students' residences and other neighborhoods were used to create a passive sampling network, allowing the measurement of atmospheric levels of pollutants in urban areas and in those under industrial influence. The assembly of the passive samplers, including impregnation of filters and chemical analysis were part of the students' practice tasks. The results were analyzed taking into consideration the Brazilian legislation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to assess a new monitoring technique of particulate and trace metals in the atmosphere via the use of a passive sampler of air pollutants in the city of Goiânia. The average particulate weight and average concentrations of metals Fe, Cr, Zn, Pb, Cu, Mn, and Cd were 0.1104 g and 257.5; 23.4; 17.8; 6.7; 1.9; 0.8; 0.2 μg/m²/day, respectively. Higher Pb and Cr concentrations were obtained in areas with intense traffic. This study revealed that it is possible to monitor trace metals with passive sampling, developed at a low cost and operational facility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fusarium head blight (FHB) is a disease of increasing concern in the production of wheat (Triticum aestivum). This work studied some of the factors affecting the density of airborne Gibberella zeae inoculum. Spore samplers were placed at the edge of a field in order to observe spore deposition over a period of 45 days and nights in September and October, the period that coincides with wheat flowering. Gibberella zeae colonies were counted for each period and values transformed to relative density. A stepwise regression procedure was used to identify weather variables helpful in predicting spore cloud density. In general, a predominant night-time spore deposition was observed. Precipitation and daily mean relative humidity over 90% were the factors most hightly associated with peak events of spores in the air. Models for predicting spore cloud density simulated reasonably well with the fluctuation of airborne propagules during both night and day, with potential to be integrated into an FHB risk model framework.