10 resultados para Retinal image quality metric
em Scielo Saúde Pública - SP
Resumo:
Objective:To evaluate the evolution of mammographic image quality in the state of Rio de Janeiro on the basis of parameters measured and analyzed during health surveillance inspections in the period from 2006 to 2011.Materials and Methods:Descriptive study analyzing parameters connected with imaging quality of 52 mammography apparatuses inspected at least twice with a one-year interval.Results:Amongst the 16 analyzed parameters, 7 presented more than 70% of conformity, namely: compression paddle pressure intensity (85.1%), films development (72.7%), film response (72.7%), low contrast fine detail (92.2%), tumor mass visualization (76.5%), absence of image artifacts (94.1%), mammography-specific developers availability (88.2%). On the other hand, relevant parameters were below 50% conformity, namely: monthly image quality control testing (28.8%) and high contrast details with respect to microcalcifications visualization (47.1%).Conclusion:The analysis revealed critical situations in terms of compliance with the health surveillance standards. Priority should be given to those mammography apparatuses that remained non-compliant at the second inspection performed within the one-year interval.
Resumo:
There is no paucity of methods for diagnosing Cryptosporidium spp. infection. The merits of immunoassays notwithstanding, microscopic identification of Cryptosporidium spp. oocysts in fecal samples remains an important diagnostic procedure. It owes the persistence of its use to such characteristics as dispensing with expensive equipment and kits, requiring only basic laboratory facilities, and having a low probability of false positive results when permanent slides are prepared, which can be re-examined in case of doubt. Cryptosporidium spp. oocysts can be readily identified in fecal smears prepared according to a regressive iron hematoxylin staining technique. The number of steps and their duration, as well as costs, were reduced to a minimum without loss of image quality and permanence of the preparations.
Resumo:
OBJECTIVE: To evaluate a comprehensive MRI protocol that investigates for cancer, vascular disease, and degenerative/inflammatory disease from the head to the pelvis in less than 40 minutes on a new generation 48-channel 3T system. MATERIALS AND METHODS: All MR studies were performed on a 48-channel 3T MR scanner. A 20-channel head/neck coil, two 18-channel body arrays, and a 32-channel spine array were employed. A total of 4 healthy individuals were studied. The designed protocol included a combination of single-shot T2-weighted sequences, T1-weighted 3D gradient-echo pre- and post-gadolinium. All images were retrospectively evaluated by two radiologists independently for overall image quality. RESULTS: The image quality for cancer was rated as excellent in the liver, pancreas, kidneys, lungs, pelvic organs, and brain, and rated as fair in the colon and breast. For vascular diseases ratings were excellent in the aorta, major branch vessel origins, inferior vena cava, portal and hepatic veins, rated as good in pulmonary arteries, and as poor in the coronary arteries. For degenerative/inflammatory diseases ratings were excellent in the brain, liver and pancreas. The inter-observer agreement was excellent. CONCLUSION: A comprehensive and time efficient screening for important categories of disease processes may be achieved with high quality imaging in a new generation 48-channel 3T system.
Resumo:
Abstract In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI) has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation.
Resumo:
Abstract Objective: To propose a protocol for pulmonary angiography using 64-slice multidetector computed tomography (64-MDCT) with 50 mL of iodinated contrast material, in an unselected patient population, as well as to evaluate vascular enhancement and image quality. Materials and Methods: We evaluated 29 patients (22-86 years of age). The body mass index ranged from 19.0 kg/m2 to 41.8 kg/m2. Patients underwent pulmonary CT angiography in a 64-MDCT scanner, receiving 50 mL of iodinated contrast material via venous access at a rate of 4.5 mL/s. Bolus tracking was applied in the superior vena cava. Two experienced radiologists assessed image quality and vascular enhancement. Results: The mean density was 382 Hounsfield units (HU) for the pulmonary trunk; 379 and 377 HU for the right and left main pulmonary arteries, respectively; and 346 and 364 HU for the right and left inferior pulmonary arteries, respectively. In all patients, subsegmental arteries were analyzed. There were streak artifacts from contrast material in the superior vena cava in all patients. However, those artifacts did not impair the image analysis. Conclusion: Our findings suggest that pulmonary angiography using 64-MDCT with 50 mL of iodinated contrast can produce high quality images in unselected patient populations.
Resumo:
Single-photon emission computed tomography (SPECT) is a non-invasive imaging technique, which provides information reporting the functional states of tissues. SPECT imaging has been used as a diagnostic tool in several human disorders and can be used in animal models of diseases for physiopathological, genomic and drug discovery studies. However, most of the experimental models used in research involve rodents, which are at least one order of magnitude smaller in linear dimensions than man. Consequently, images of targets obtained with conventional gamma-cameras and collimators have poor spatial resolution and statistical quality. We review the methodological approaches developed in recent years in order to obtain images of small targets with good spatial resolution and sensitivity. Multipinhole, coded mask- and slit-based collimators are presented as alternative approaches to improve image quality. In combination with appropriate decoding algorithms, these collimators permit a significant reduction of the time needed to register the projections used to make 3-D representations of the volumetric distribution of target’s radiotracers. Simultaneously, they can be used to minimize artifacts and blurring arising when single pinhole collimators are used. Representation images are presented, which illustrate the use of these collimators. We also comment on the use of coded masks to attain tomographic resolution with a single projection, as discussed by some investigators since their introduction to obtain near-field images. We conclude this review by showing that the use of appropriate hardware and software tools adapted to conventional gamma-cameras can be of great help in obtaining relevant functional information in experiments using small animals.
Resumo:
The cellular structure of healthy food products, with added dietary fiber and low in calories, is an important factor that contributes to the assessment of quality, which can be quantified by image analysis of visual texture. This study seeks to compare image analysis techniques (binarization using Otsu’s method and the default ImageJ algorithm, a variation of the iterative intermeans method) for quantification of differences in the crumb structure of breads made with different percentages of whole-wheat flour and fat replacer, and discuss the behavior of the parameters number of cells, mean cell area, cell density, and circularity using response surface methodology. Comparative analysis of the results achieved with the Otsu and default ImageJ algorithms showed a significant difference between the studied parameters. The Otsu method demonstrated the crumb structure of the analyzed breads more reliably than the default ImageJ algorithm, and is thus the most suitable in terms of structural representation of the crumb texture.
Resumo:
Objective: To learn about the experiences of adolescents diagnosed with idiopathic scoliosis. Method: Integrative review of the literature published within a specified time frame. Results: For both sexes, the predominant clinical symptom of this condition appears to be the negative effect that the deformity exerts on perceived self-image. Quantitative studies used numerical scores to assess perceptions of body image but did not analyse emotional aspects. Patients treated surgically were found to have a better self-image than patients treated with a brace. Quality of life was improved by a reduction in the magnitude of the curve. Conclusion: Spinal deformity exerts a psychological effect on adolescent girls.
Resumo:
Objective To develop procedures to ensure consistency of printing quality of digital images, by means of hardcopy quantitative analysis based on a standard image. Materials and Methods Characteristics of mammography DI-ML and general purpose DI-HL films were studied through the QC-Test utilizing different processing techniques in a FujiFilm®-DryPix4000 printer. A software was developed for sensitometric evaluation, generating a digital image including a gray scale and a bar pattern to evaluate contrast and spatial resolution. Results Mammography films showed maximum optical density of 4.11 and general purpose films, 3.22. The digital image was developed with a 33-step wedge scale and a high-contrast bar pattern (1 to 30 lp/cm) for spatial resolution evaluation. Conclusion Mammographic films presented higher values for maximum optical density and contrast resolution as compared with general purpose films. The utilized digital processing technique could only change the image pixels matrix values and did not affect the printing standard. The proposed digital image standard allows greater control of the relationship between pixels values and optical density obtained in the analysis of films quality and printing systems.
Resumo:
The development of new procedures for quickly obtaining accurate information on the physiological potential of seed lots is essential for developing quality control programs for the seed industry. In this study, the effectiveness of an automated system of seedling image analysis (Seed Vigor Imaging System - SVIS) in determining the physiological potential of sun hemp seeds and its relationship with electrical conductivity tests, were evaluated. SVIS evaluations were performed three and four days after sowing and data on the vigor index and the length and uniformity of seedling growth were collected. The electrical conductivity test was made on 50 seed replicates placed in containers with 75 mL of deionised water at 25 ºC and readings were taken after 1, 2, 4, 8 and 16 hours of imbibition. Electrical conductivity measurements at 4 or 8 hours and the use of the SVIS on 3-day old seedlings can effectively detect differences in vigor between different sun hemp seed lots.