133 resultados para Restenosis post-angioplasty

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The complete spectrum of estrogen vascular effects remains unclear. In particular, estrogen effects in the vascular response to profound injury in males have not been explored in detail. Therefore, we submitted 44 male New Zealand rabbits weighing 3.4 ± 0.6 kg to overdistention balloon injury of the right iliac artery. Rabbits were given 17ß-estradiol (5.45 µmol/day, sc) or vehicle for 7 days before and 14 days after injury, when the arteries were examined by post-mortem histomorphometry. Arteriographic caliber was assessed in vivo at baseline and before sacrifice. On day 14 after injury, in vivo arteriographic caliber (baseline = 2.44 ± 0.43 mm) was decreased by 23.1 ± 0.1% in controls and by 44.5 ± 0.1% in estrogen-treated rabbits (P < 0.001). Neither the neointimal area nor the neointima/media area ratio changed after estrogen treatment. Collagen fraction was increased in the media and neointima of estrogen-treated rabbits vs control (1.38 ± 1.30 vs 0.35 ± 0.67, respectively, P = 0.01). Taken together, these findings suggest that estrogen increased negative vascular remodeling. Transcription of endothelial and inducible nitric oxide synthases (eNOS and iNOS) was analyzed by RT-PCR. eNOS mRNA expression was marginally increased after estrogen (P = 0.07) and injury. iNOS mRNA was increased 2- to 3-fold on day 14 after injury. With estrogen treatment, iNOS mRNA increased in uninjured arteries and exhibited a further 5.5-fold increase after injury. We concluded that estrogen increased lumen loss after balloon injury in male rabbits, likely by increased negative remodeling, which may be related to increased iNOS transcriptional rates.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To compare circulating plasma levels of immunoinflammatory markers in patients with known de novo coronary artery disease and patients with postangioplasty restenosis. METHODS: Using enzymatic immunoabsorbent assay, we measured plasma levels of soluble interleukin-2 receptosr, tumor necrosis factor alpha, and soluble tumor necrosis alpha receptors I and II in 11 patients with restenosis postcoronary angioplasty (restenosis group), in 10 patients with primary atherosclerosis (de novo group) who were referred for coronary angiography because of stable or unstable angina, and in 9 healthy volunteers (control group). Levels of soluble interleukin-2 receptors were significantly higher in the de novo group compared with that in the restenosis and control groups. Levels were also higher in the restenosis group compared with that in the control group. Plasma levels of tumor necrosis alpha and receptor levels were significantly higher in the de novo group compared to with that in the restenosis and control groups, but levels in the restenosis group were not different from that in the controls. CONCLUSION: Coronary artery disease, either primary or secondary to restenosis, is associated with significant immunoinflammatory activity, which can be assessed by examining the extent of circulating plasma levels of inflammatory markers. Moreover, patients with de novo lesions appear to have increased inflammatory activity compared with patients with restenosis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: to assess post-angioplasty myointimal hyperplasia in iliac artery of rabbits treated with extract of Moringa oleifera leaves. Methods : we conducted a randomized trial in laboratory animals for five weeks of follow-up, developed in the Vivarium of Pharmaceutical Technology Laboratory of the Universidade Federal da Paraíba. We used rabbits from the New Zealand breed, subjected to a hypercholesterolemic diet and angioplasty of the external iliac artery, randomized into two groups: M200 Group (n=10) - rabbits treated with 200mg/kg/day of Moringa oleifera leaves extract orally; SF group (n=10) - rabbits treated with 0.9% saline orally. After five weeks, the animals were euthanized and the iliac arteries prepared for histology. Histological sections were analyzed by digital morphometry. Statistical analysis was performed using the Student's t test. The significance level was 0.05. Results : there was no significant difference in myointimal hyperplasia between M200 and SF groups when comparing the iliac arteries submitted to angioplasty. Conclusion : there was no difference of myointimal hyperplasia between groups treated with saline and Moringa oleifera after angioplasty.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

OBJETIVE: With the increased use of intracoronary stents, in-stent restenosis has become a clinically significant drawback in invasive cardiology. We retrospectively assessed the short- and long-term outcomes after excimer laser coronary angioplasty of in-stent restenosis. METHODS: Twenty-five patients with 33 incidents of in-stent restenosis treated with excimer laser coronary angioplasty (ELCA) were analyzed. Sixty-six percent were males, mean age of 73±11 years, and 83% were functional class III-IV (NYHA). ELCA was performed using 23 concentric and 10 eccentric catheters with a diameter of 1.6-2.2 mm, followed by balloon angioplasty (PTCA) and ultrasound monitoring. The procedure was performed in the following vessels: left anterior descending artery, 10; left circumflex artery, 8; right coronary artery, 6; left main coronary artery, 2; and venous bypass graft, 7. RESULTS: The ELCA was successful in 71% of the cases, and PTCA was 100% successful. The diameter of the treated vessels was 3.44±0.5mm; the minimal luminal diameter (MLD) increased from 0.30mm pre-ECLA to 1.97mm post-ELCA, and to 2.94mm post-PTCA (p<0.001). The percent stenosis was reduced from 91.4±9.5% before ECLA to 42.3±14.9% after ELCA and to 14.6 ± 9.3% after PTCA (p<0.001). Seventeen (68%) patients were asymptomatic at 6 months and 15 (60%) at 1 year. New restenosis rates were 8/33 (24.2%) at 6 months and 9 /33 (27.3%) at 12 months. CONCLUSION: ELCA is safe and effective for the treatment of in-stent restenosis. In the present sample, a slight increase in new restenotic lesions between 6 and 12 months was found.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We describe here two patients with angiographic diagnosis of intrastent restenosis and regional myocardial ischemia. One stent restenosis was located in a native coronary artery and the other in a vein graft. Both were treated with cutting balloon angioplasty (CBA), inflated at low pressures. Angiographic success was obtained and both patients were discharged in the day after the procedure. Cutting balloon angioplasty using low inflation pressures achieved important luminal gains, in these two cases of intrastent restenosis. Further studies are necessary before the effectiveness of this procedure can be precisely defined.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Abstract Background: The kinetics of high-sensitivity troponin T (hscTnT) release should be studied in different situations, including functional tests with transient ischemic abnormalities. Objective: To evaluate the release of hscTnT by serial measurements after exercise testing (ET), and to correlate hscTnT elevations with abnormalities suggestive of ischemia. Methods: Patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary angioplasty were referred for ET 3 months after infarction. Blood samples were collected to measure basal hscTnT immediately before (TnT0h), 2 (TnT2h), 5 (TnT5h), and 8 hours (TnT8h) after ET. The outcomes were peak hscTnT, TnT5h/TnT0h ratio, and the area under the blood concentration-time curve (AUC) for hscTnT levels. Log-transformation was performed on hscTnT values, and comparisons were assessed with the geometric mean ratio, along with their 95% confidence intervals. Statistical significance was assessed by analysis of covariance with no adjustment, and then, adjusted for TnT0h, age and sex, followed by additional variables (metabolic equivalents, maximum heart rate achieved, anterior wall STEMI, and creatinine clearance). Results: This study included 95 patients. The highest geometric means were observed at 5 hours (TnT5h). After adjustments, peak hscTnT, TnT5h/TnT0h and AUC were 59% (p = 0.002), 59% (p = 0.003) and 45% (p = 0.003) higher, respectively, in patients with an abnormal ET as compared to those with normal tests. Conclusion: Higher elevations of hscTnT may occur after an abnormal ET as compared to a normal ET in patients with STEMI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To compare the outcome of balloon PTCA with final coronary stenosis diameter (SD) <=30%, with elective coronary stenting. METHODS: We performed a comparative analysis of the 6 month outcomes in patients treated with primary stenting and those who obtained an optimal balloon PTCA result treated during the first 12 hours of AMI onset included in the STENT PAMI randomized trial. RESULTS: The results were analysed into 3 groups: primary stenting (441 patients, SD=22±6%), optimal PTCA (245 patients), and nonoptimal PTCA (182 patients, SD= 37±5%). At the end of the 6 months primary stent group presented with the lowest restenosis(23 vs. 31 vs. 45%, p=0.001, respectively). Ischemia-driven target vessel revascularization rate (TVR) (7 vs. 15.5 vs. 19%, p=0.001, respectively). CONCLUSION: At the 6 month follow-up, primary stenting offered the lowest restenosis and ischemia-driven TVR rates. Compared to optimal balloon PTCA. Nonoptimal primary balloon PTCA pts (SD=31-50%), had the worst late angiographic outcomes and should be treated more actively with coronary stent implantation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intracoronary brachytherapy using beta or gamma radiation is currently the most efficient type of therapy for preventing the recurrence of coronary in-stent restenosis. Its implementation depends on the interaction among interventionists, radiotherapists, and physicists to assure the safety and quality of the method. The authors report the pioneering experience in Brazil of the treatment of 2 patients with coronary in-stent restenosis, in whom beta radiation was used as part of the international multicenter randomized PREVENT study (Proliferation REduction with Vascular ENergy Trial). The procedures were performed rapidly and did not require significant modifications in the traditional techniques used for conventional angioplasty. Alteration in the radiological protection devices of the hemodynamic laboratory were also not required, showing that intracoronary brachytherapy using beta radiation can be incorporated into the interventional tools of cardiology in our environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Clinical in-stent restenosis (CISR) is the main limitation of coronary angioplasty with stent implantation. Objective: Describe the clinical and angiographic characteristics of CISR and the outcomes over a minimum follow-up of 12 months after its diagnosis and treatment. Methods: We analyzed in 110 consecutive patients with CISR the clinical presentation, angiographic characteristics, treatment and combined primary outcomes (cardiovascular death, nonfatal acute myocardial infarction [AMI]) and combined secondary (unstable angina with hospitalization, target vessel revascularization and target lesion revascularization) during a minimal follow-up of one year. Results: Mean age was 61 ± 11 years (68.2% males). Clinical presentations included acute coronary syndrome (ACS) in 62.7% and proliferative ISR in 34.5%. CISR was treated with implantation of drug-eluting stents (DES) in 36.4%, Bare Metal Stent (BMS) in 23.6%, myocardial revascularization surgery in 18.2%, balloon angioplasty in 15.5% and clinical treatment in 6.4%. During a median follow-up of 19.7 months, the primary outcome occurred in 18 patients, including 6 (5.5%) deaths and 13 (11.8%) AMI events. Twenty-four patients presented a secondary outcome. Predictors of the primary outcome were CISR with DES (HR = 4.36 [1.44–12.85]; p = 0.009) and clinical treatment for CISR (HR = 10.66 [2.53–44.87]; p = 0.001). Treatment of CISR with BMS (HR = 4.08 [1.75–9.48]; p = 0.001) and clinical therapy (HR = 6.29 [1.35–29.38]; p = 0.019) emerged as predictors of a secondary outcome. Conclusion: Patients with CISR present in most cases with ACS and with a high frequency of adverse events during a medium-term follow-up.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transluminal coronary angioplasty is a routine therapeutic intervention in coronary heart disease. Despite the high rate of primary success, restenosis continues to be its major limitation. Porcine models have been considered to be the most adequate experimental models for studying restenosis. One limitation of porcine models is the need for radiological guidance and the expenses involved. The objective of the present study was to adapt an experimental model of angioplasty in the porcine carotid artery that does not require radiological equipment. Eight animals were used to develop the technique of balloon injury to the common carotid artery by dissection without radiological guidance. This technique was then employed in six other animals. Under anesthesia, the left common carotid artery was dissected and incised at the carotid sinus for insertion of an over-the-wire angioplasty balloon towards the aorta. Overstretch injury of the carotid artery was performed under direct visualization. After 30 days, the arteries were excised and pressure-fixated. Uninjured carotid arteries from 3 additional animals were used as controls. A decreased luminal area associated with intimal hyperplasia and medial reaction was observed in all injured arteries. Immunohistochemistry identified the intimal hyperplastic cells as smooth muscle cells. Computerized morphometry of the ballooned segments revealed the following mean areas: lumen 2.12 mm2 (± 1.09), intima 0.22 mm2 (± 0.08), media 3.47 mm2 (± 0.67), and adventitia 1.11 mm2 (± 0.34). Our experimental model of porcine carotid angioplasty without radiological guidance induced a vascular wall reaction and permitted the quantification of this response. This porcine model may facilitate the study of vascular injury and its response to pharmacological interventions

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hypertension is one of the major precursors of atherosclerotic vascular disease, and vascular smooth muscle abnormal cell replication is a key feature of plaque formation. The present study was conducted to examine the relationship between hypertension and smooth muscle cell proliferation after balloon injury and to correlate neointima formation with resting membrane potential of uninjured smooth muscle cells, since it has been suggested that altered vascular function in hypertension may be related to the resetting of the resting membrane potential in spontaneously hypertensive rats (SHR). Neointima formation was induced by balloon injury to the carotid arteries of SHR and renovascular hypertensive rats (1K-1C), as well as in their normotensive controls, i.e., Wistar Kyoto (WKY) and normal Wistar (NWR) rats. After 14 days the animals were killed and the carotid arteries were submitted to histomorphometric and immunohistochemical analyses. Resting membrane potential measurements showed that uninjured carotid arteries from SHR smooth muscle cells were significantly depolarized (-46.5 ± 1.9 mV) compared to NWR (-69 ± 1.4 mV), NWR 1K-1C (-60.8 ± 1.6 mV), WKY (-67.1 ± 3.2 mV) and WKY 1K-1C (-56.9 ± 1.2 mV). The SHR arteries responded to balloon injury with an enhanced neointima formation (neo/media = 3.97 ± 0.86) when compared to arteries of all the other groups (NWR 0.93 ± 0.65, NWR 1K-1C 1.24 ± 0.45, WKY 1.22 ± 0.32, WKY 1K-1C 1.15 ± 0.74). Our results indicate that the increased fibroproliferative response observed in SHR is not related to the hypertensive state but could be associated with the resetting of the carotid smooth muscle cell resting membrane potential to a more depolarized state.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Controversy exists regarding the diagnostic accuracy, optimal technique, and timing of exercise testing after percutaneous coronary intervention. The objectives of the present study were to analyze variables and the power of exercise testing to predict restenosis or a new lesion, 6 months after the procedure. Eight-four coronary multi-artery diseased patients with preserved ventricular function were studied (66 males, mean age of all patients: 59 ± 10 years). All underwent coronary angiography and exercise testing with the Bruce protocol, before and 6 months after percutaneous coronary intervention. The following parameters were measured: heart rate, blood pressure, rate-pressure product (heart rate x systolic blood pressure), presence of angina, maximal ST-segment depression, and exercise duration. On average, 2.33 lesions/patient were treated and restenosis or progression of disease occurred in 46 (55%) patients. Significant increases in systolic blood pressure (P = 0.022), rate-pressure product (P = 0.045) and exercise duration (P = 0.003) were detected after the procedure. Twenty-seven (32%) patients presented angina during the exercise test before the procedure and 16 (19%) after the procedure. The exercise test for the detection of restenosis or new lesion presented 61% sensitivity, 63% specificity, 62% accuracy, and 67 and 57% positive and negative predictive values, respectively. In patients without restenosis, the exercise duration after percutaneous coronary intervention was significantly longer (460 ± 154 vs 381 ± 145 s, P = 0.008). Only the exercise duration permitted us to identify patients with and without restenosis or a new lesion.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This text focuses on the major drivers of Brazilian agricultural cooperation in Africa as conceived and pursued from 2004 to 2014, with emphasis on the impacts of political and economic international changes that took place in that period, and particularly the impacts of the 2008 economic crisis, in framing Brazil's foreign policy and development assistance initiatives. It addresses current international forces and developments at the systemic level, but also analyses recent economic domestic developments, in particular those directly related to Brazilian agriculture and those related to the policy framework of its evolving internationalization. Special attention is paid to the dual dimensions of Brazilian agricultural policy and to its projection in agricultural cooperation as pursed in Africa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The strawberry is as non-climacteric fruit, but has a high post-harvest respiration rate, which leads to a rapid deterioration at room temperature. This study aimed to evaluate the application of biodegradable coating on postharvest conservation of organic strawberries, cv. Camarosa, packed in plastic hinged boxes and stored at 10ºC. The treatments consisted of: a) control; b) 2% cassava starch; c) 1% chitosan; and d) 2% cassava starch + 1% chitosan. Physical and chemical characteristics of fruits were evaluated at 3, 6 and 9 days of storage, and microbiological and sensory analyses were carried out at the end of the storage period. The treatments influenced positively the post-harvest quality of organic strawberries. The coating cassava starch + chitosan provided the best results, with less than 6% of loss in fruit mass, lower counts of yeast and psychrophilic microorganisms and the best appearance according to the sensory analysis.