87 resultados para Residual-Based Cointegration Test

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the specificity of a rapid immunochromatographic test that was developed to detect antibodies against the rK39 antigen for the diagnosis of visceral leishmaniasis (VL). This evaluation was performed using sera from patients with a confirmed diagnosis of active cutaneous leishmaniasis. The sera from 272 patients with a confirmed diagnosis of localised cutaneous leishmaniasis (CL) who resided in an area endemic for Leishmania braziliensis in Brazil were obtained before the initiation of antileishmanial treatment. Kalazar Detect(r)(InBios, Seattle, WA) recombinant K39 antigen-based immunochromatographic strips were used according to the manufacturer's instructions. The test results were evaluated independently by two examiners in sequential order. The positive controls for the test included five serum samples from five patients with parasitologically confirmed diagnosis of VL caused by Leishmania infantum in Brazil. Overall, 100% of the samples obtained from patients with CL were negative, confirming the absence of a serological cross-reaction for individuals with cutaneous disease when these patients were evaluated using the rapid test. The lack of a cross-reaction in patients who were infected by parasites of the same genus highlights the specificity of the rK39 antigen for the diagnosis of VL in areas with the sympatric circulation of L. braziliensis and L. infantum.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nonsyndromic oral clefts (NSOC) are the most common craniofacial birth defects in humans. The etiology of NSOC is complex, involving both genetic and environmental factors. Several genes that play a role in cellular proliferation, differentiation, and apoptosis have been associated with clefting. For example, variations in the homeobox gene family member MSX1, including a CA repeat located within its single intron, may play a role in clefting. The aim of this study was to investigate the association between MSX1CA repeat polymorphism and NSOC in a Southern Brazilian population using a case-parent triad design. We studied 182 nuclear families with NSOC recruited from the Hospital de Clínicas de Porto Alegre in Southern Brazil. The polymorphic region was amplified by the polymerase chain reaction and analyzed by using an automated sequencer. Among the 182 families studied, four different alleles were observed, at frequencies of 0.057 (175 bp), 0.169 (173 bp), 0.096 (171 bp) and 0.67 (169 bp). A transmission disequilibrium test with a family-based association test (FBAT) software program was used for analysis. FBAT analysis showed overtransmission of the 169 bp allele in NSOC (P=0.0005). These results suggest that the CA repeat polymorphism of theMSX1 gene may play a role in risk of NSOC in populations from Southern Brazil.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A rapid test based on an immunochromatography assay - Determine™ Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine™ test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine™ is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A ligase chain reaction DNA amplification method for direct detection of Mycobacterium tuberculosis (Abbott LCx MTB) in respiratory specimens was evaluated. Results from LCx MTB Assay were compared with those from acid fast bacilli smear, culture, and final clinical diagnosis for each patient. A total of 297 respiratory specimens (sputum and bronchial lavage) from 193 patients were tested. The sensitivity, specificity, positive predictive value and negative predictive value of LCx vs culture were 92.7%, 93%, 67.8% and 98.7%, respectively. When compared to the clinical final diagnosis, the sensitivity, specificity, PPV and NPV for LCx were 88.9%, 96.8%, 86.5% and 97.4%, respectively. The sensitivity of LCx MTB assay was 75% for smear-negative, culture positive samples. The results indicate that LCx MTB assay is a rapid, simple and valuable technique as a complementary tool for the diagnosis of tuberculosis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A field survey on schistosomiais was carried out in 1998, in the municipality of Pedro de Toledo, a low endemic area in the state of São Paulo, Brazil. According to the parasitologic Kato-Katz method, the prevalence rate was 1.6%, with an infection intensity of 40.9 eggs per gram of stool. By the immunofluorescence test (IFT) for detection of IgG and IgM antibodies in the serum, IgG-IFT and IgM-IFT, respectively, prevalence indices of 33.2% and 33.5% were observed. To assess the impact of the schistosomiasis control program in the area, parasitologic and serologic data obtained in 1998, analyzed according to the age, sex, and residence zone, were compared to previous data obtained in a epidemiologic study carried out in 1980, when prevalence indices were of 22.8% and 55.5%, respectively by Kato-Katz and IgG-IFT. A significant fall of the prevalence was observed, indicating that the control measures were effective. Nonetheless, residual transmission was observed, demonstrating the need for a joint effort to include new approaches for better understanding the real situation and improving the control of the disease in low endemic areas.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Abstract Objective: To evaluate three-dimensional translational setup errors and residual errors in image-guided radiosurgery, comparing frameless and frame-based techniques, using an anthropomorphic phantom. Materials and Methods: We initially used specific phantoms for the calibration and quality control of the image-guided system. For the hidden target test, we used an Alderson Radiation Therapy (ART)-210 anthropomorphic head phantom, into which we inserted four 5mm metal balls to simulate target treatment volumes. Computed tomography images were the taken with the head phantom properly positioned for frameless and frame-based radiosurgery. Results: For the frameless technique, the mean error magnitude was 0.22 ± 0.04 mm for setup errors and 0.14 ± 0.02 mm for residual errors, the combined uncertainty being 0.28 mm and 0.16 mm, respectively. For the frame-based technique, the mean error magnitude was 0.73 ± 0.14 mm for setup errors and 0.31 ± 0.04 mm for residual errors, the combined uncertainty being 1.15 mm and 0.63 mm, respectively. Conclusion: The mean values, standard deviations, and combined uncertainties showed no evidence of a significant differences between the two techniques when the head phantom ART-210 was used.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Two sensitive spectrophotometric methods are described for the determination of lansoprazole (LPZ) in bulk drug and in capsule formulation. The methods are based on the oxidation of lansoprazole by insitu generated bromine followed by determination of unreacted bromine by two different reaction schemes. In one procedure (method A), the residual bromine is treated with excess of iron (II), and the resulting iron (III) is complexed with thiocyanate and measured at 470 nm. The second approach (method B) involves treating the unreacted bromine with a measured excess of iron (II) and remaining iron (II) is complexed with orthophenanthroline at a raised pH, and measured at 510 nm. In both methods, the amount of bromine reacted corresponds to the amount of LPZ. The experimental conditions were optimized. In method A, the absorbance is found to decrease linearly with the concentration of LPZ (r = -0.9986) where as in the method B a linear increase in absorbance occurs (r = 0.9986) The systems obey Beer's law for 0.5-4.0 and 0.5-6.0 µg mL-1 for method A and method B, respectively. The calculated molar absorptivity values are 3.97µ10(4) and 3.07µ10(4) L mol-1cm-1 for method A and method B, respectively, and the corresponding Sandell sensitivity values are 0.0039 and 0.0013 µg cm-2. The limit of detection (LOD) and quantification (LOQ) are also reported for both methods. Intra-day and inter-day precision, and accuracy of the methods were established as per the current ICH guidelines. The methods were successfully applied to the determination of LPZ in capsules and the results tallied well with the label claim and the results were statistically compared with those of a reference method by applying the Student's t-test and F-test. No interference was observed from the concomitant substances normally added to capsules. The accuracy and validity of the methods were further ascertained by performing recovery experiments via standard-addition method.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Two sensitive spectrophotometric methods are described for the determination of simvastatin (SMT) in bulk drug and in tablets. The methods are based on the oxidation of SMT by a measured excess of cerium (IV) in acid medium followed by determination of unreacted oxidant by two different reaction schemes. In one procedure (method A), the residual cerium (IV) is reacted with a fixed concentration of ferroin and the increase in absorbance is measured at 510 nm. The second approach (method B) involves the reduction of the unreacted cerium (IV) with a fixed quantity of iron (II), and the resulting iron (III) is complexed with thiocyanate and the absorbance measured at 470 nm. In both methods, the amount of cerium (IV) reacted corresponds to SMT concentration. The experimental conditions for both methods were optimized. In method A, the absorbance is found to increase linearly with SMT concentration (r = 0.9995) whereas in method B, the same decreased (r = -0.9943). The systems obey Beer's law for 0.6-7.5 and 0.5-5.0 µg mL-1 for method A and method B, respectively. The calculated molar absorptivity values are 2.7 X 10(4) and 1.06 X 10(5) Lmol-1 cm-1, respectively; and the corresponding sandel sensitivity values are 0.0153 and 0.0039µg cm-2, respectively. The limit of detection (LOD) and quantification (LOQ) are reported for both methods. Intra-day and inter-day precision, and accuracy of the methods were established as per the current ICH guidelines. The methods were successfully applied to the determination of SMT in tablets and the results were statistically compared with those of the reference method by applying the Student's t-test and F-test. No interference was observed from the common excipients added to tablets. The accuracy and validity of the methods were further ascertained by performing recovery experiments via standard addition procedure.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coronary artery disease (CAD) is a worldwide leading cause of death. The standard method for evaluating critical partial occlusions is coronary arteriography, a catheterization technique which is invasive, time consuming, and costly. There are noninvasive approaches for the early detection of CAD. The basis for the noninvasive diagnosis of CAD has been laid in a sequential analysis of the risk factors, and the results of the treadmill test and myocardial perfusion scintigraphy (MPS). Many investigators have demonstrated that the diagnostic applications of MPS are appropriate for patients who have an intermediate likelihood of disease. Although this information is useful, it is only partially utilized in clinical practice due to the difficulty to properly classify the patients. Since the seminal work of Lotfi Zadeh, fuzzy logic has been applied in numerous areas. In the present study, we proposed and tested a model to select patients for MPS based on fuzzy sets theory. A group of 1053 patients was used to develop the model and another group of 1045 patients was used to test it. Receiver operating characteristic curves were used to compare the performance of the fuzzy model against expert physician opinions, and showed that the performance of the fuzzy model was equal or superior to that of the physicians. Therefore, we conclude that the fuzzy model could be a useful tool to assist the general practitioner in the selection of patients for MPS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study aimed at developing an Aloe vera-based formula for topical use on horse hoof and evaluating whether the treatment affects hooves growth and balance. Six healthy male horses between the ages of 3 and 17 years (12±5.25) were used, all semi-confined animals for breeding purposes. Before beginning A. vera treatment, animals underwent two trimming procedures with a 45 days-interval. After the second trimming, one of the forelimbs and one of the hindlimbs of 4 horses was weekly treated by topical application of the glycolic extract of A. vera at 20%. The contralateral limb, randomly chosen, received the extract at 50%. The hooves of the other animals were treated with propylene glycol. Treatment was done for 225 days and, during this time, animals underwent periodic trimming. Variables related to growth and balance of the hooves were measured before and after trimming. Data were analyzed using chi-square test and regression analysis at 5% significance. Growth rate of the hooves was not related to treatment. On the other hand, the 50% extract was related to the majority of the hooves in balance (p<0.05). Results suggest that a weekly topical treatment with A. vera glycolic extract does not improve the growth rate of the hooves; however, when applied at a high concentration, it improves their balance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present work was to evaluate 27 progenies of cocoa crosses considering the agronomic traits and select F1 plants within superior crosses. The experiment was installed in March 2005, in the Experimental Station Joaquim Bahiana (ESJOB), in Itajuipe, Bahia. The area of the experiment is of approximately 3 ha, with a total of 3240 plants. Thirteen evaluations of vegetative brooms, five of cushion brooms and 15 of number of pods per plant were accomplished. Thirty pollinations were made for each selected plant to test for self-compatibility. The production, based on the number of pods per plant, and resistance to witches´ broom indicated CEPEC 94 x CCN 10, RB 39 x CCN 51 and CCN 10 x VB 1151 as superior progenies. All selections tested were self-compatible. The analyses of progenies and individual tree data, associated to visual field observations, allowed the selection of 17 plants which were included in a network of regional tests to determine the phenotypic stability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To estimate the prevalence of alcohol abuse/dependence and identify associated factors among demographic, family, socioeconomic and mental health variables. METHODS: A household survey was carried out in the urban area of Campinas, southeastern Brazil, in 2003. A total of 515 subjects, aged 14 years or more were randomly selected using a stratified cluster sample. The Self-Report Questionnaire and the Alcohol Use Disorder Identification Test were used in the interview. Prevalences were calculated, and univariate and multivariate logistic analyses performed by estimating odds ratios and 95% confidence intervals. RESULTS: The estimated prevalence of alcohol abuse/dependence was 13.1% (95% CI: 8.4;19.9) in men and 4.1% (95% CI: 1.9;8.6) in women. In the final multiple logistic regression model, alcohol abuse/dependence was significantly associated with age, income, schooling, religion and illicit drug use. The adjusted odds ratios were significantly higher in following variables: income between 2,501 and 10,000 dollars (OR=10.29); income above 10,000 dollars (OR=10.20); less than 12 years of schooling (OR=13.42); no religion (OR=9.16) or religion other than Evangelical (OR=4.77); and illicit drug use during lifetime (OR=4.47). Alcohol abuse and dependence patterns were different according to age group. CONCLUSIONS: There is a significantly high prevalence of alcohol abuse/dependence in this population. The knowledge of factors associated with alcohol abuse, and differences in consumption patterns should be taken into account in the development of harm reduction strategies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Between October 1988 and April 1989 a cross-sectional survey was carried out in six out of eight blood banks of Goiânia, Central Brazil. Subjects attending for first-time blood donation in the mornings of the study period (n = 1358) were interviewed and screened for T. cruzi infection as a part of a major study among blood donors. Tests to anti-T. cruzi antibodies were performed, simultaneously, by indirect hem agglutination test (IHA) and complement fixation test (CFT). A subject was considered seropositive when any one of the two tests showed a positive result. Information on age, sex, place of birth, migration and socio-economic level was recorded. Results from this survey were compared with seroprevalence rates obtained in previous studies in an attempt to analyse trend of T. cruzi infection in an endemic urban area. The overall seroprevalence of T. cruzi infection among first-time donors was found to be 3.5% (95% confidence interval 2.5%-4.5% ). The seroprevalence rate increased with age up to 45 years and then decreased. Migrants from rural areas had higher seroprevalence rates than subjects from urban counties (1.8%-16.2% vs. 0%-3.6%). A four fold decrease in prevalence rates was observed when these rates were compared with those of fifteen years ago. Two possible hypotheses to explain this difference were suggested: 1. a cohort effect related with the decrease of transmission in rural areas and/or 2. a differential proportion of people of rural origin among blood donors between the two periods. The potential usefulness of blood banks as a source of epidemiological information to monitor trends of T. cruzi infection in an urban adult population was stressed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to validate the 14C-urea breath test for use in diagnosis of Helicobacter pylori infection. Thirty H. pylori positive patients, based on histologic test and thirty H. pylori negative patients by histology and anti-H. pylori IgG entered the study. Fasting patients drank 5 uCi of 14C-urea in 20 ml of water. Breath samples were collected at 0, 5, 10, 15, 20 and 30 min. The difference of cpm values between the two groups was significant at all the time intervals, besides time 0 (p<0.0001). At 20 min, the test gave 100% sensitivity and specificity with a cut-off value of 562 cpm. Females were higher expirers than males (p=0.005). 14C-urea breath test is highly accurate for Helicobacter pylori diagnosis. It is fast, simple and should be the non-invasive test used after treating Helicobacter pylori infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present study ELISA was standardized for the diagnosis of swine cysticercosis based on necropsy parameters and confirmed positive and negative control sera. Serum samples from pigs with other infections were also assayed to determine possible cross-reactions. Four antigens were assayed: from Taenia crassiceps vesicular fluid (VF-Tcra) and crude larvae extract (T-Tcra), and from Taenia solium extracts of scolex (S-Ts) and of larvae (T-Ts). A checkerboard evaluation of antigen, serum and conjugate dilutions, as well as the use of Tween-20 and skim cow milk in wash and blocking solution had a marked effect on improving ELISA performance. All the antigens showed a good performance, but VF-Tcra was the best, with 96.0% and 80.0% sensitivities for cut-offs respectively at 2sd and 3sd, and corresponding specificities of 97.5% and 100.0%. Cross-reactivity was observed only with hydatidosis and ascaridiosis. In view of the high performance observed, the ELISA test should be recommended for the diagnosis of cysticercosis in suspected swine in slaughterhouses and for the screening of cysticercosis in swine production. These results will support integrated measures of cysticercosis control throughout the chain of swine production, effectively contributing to public health.