72 resultados para Refinery effluents
em Scielo Saúde Pública - SP
Resumo:
The employment of local soils for extraction of metallic elements was evaluated through batch tests to treat wastewaters generated in a petroleum refinery plant in southern Brazil. Clay and organic carbon content and clay mineralogy provide these soils, in principle, with moderate metal retention capacity. The following retention order was established: Cr3+ > Pb2+ > Cu2+ > Hg2+ > Cd2+, with total amount of metals retained varying from 36 to 65 meq kg-1. The results show the high efficiency of local soils for extracting metals from liquid effluents through sorption and precipitation processes under acid pH conditions.
Resumo:
This work discusses an analytical procedure for analysis of sulfur compounds in treated petroleum refinery gaseous effluents using a sulfur chemiluminescence detector with dual plasma burner (SCD-DP). Calibration was accomplished by using standards and gaseous streams of known concentration of sulfur compounds. The response factors agree with the calibration table of ASTM standard D 5504 (2008). The detection range for sulfur compounds is in μg m-3. The analytical procedure allowed the construction of a chromatographic chart of sulfur compounds present in several refinery gaseous effluents. SO2 was the most difficult compound to be determined because of its high reactivity.
Resumo:
Three bacterial strains were isolated from the activated sludge system of petroleum refinery wastewater, identified by partial sequencing of 16S rDNA, and classified as Acinetobacter genomospecies 3, Bacillus pumilus, and Bacillus flexus. The degradation efficiency of aromatic hydrocarbons was evaluated by gas chromatography with a flame ionization detector. In a mineral medium containing anthracene and phenanthrene and the consortium of microorganisms, the removal efficiency was 96% and 99%, respectively, after 30 days. The good rate of hydrocarbon degradation proves the operational efficiency of the microbial consortium in treating effluents containing these compounds.
Resumo:
Giardia and Cryptosporidium have caused several outbreaks of gastroenteritis in humans associated with drinking water. Contaminated sewage effluents are recognized as a potential source of waterborne protozoa. Due to the lack of studies about the occurrence of these parasites in sewage samples in Brazil, we compared the efficiency of two procedures for concentrating cysts and oocysts in activated sludge samples of one sewage treatment plant. For this, the samples were submitted to i) concentration by the ether clarification procedure (ECP) and to ii) purification by sucrose flotation method (SFM) and aliquots of the pellets were examined by immunofluorescence. Giardia cysts were present in all samples (100.0%; n = 8) when using ECP and kit 1 reagents, while kit 2 resulted in six positive samples (85.7%; n = 7). As for SFM, cysts were detected in 75.0% and 100.0% of these samples (for kit 1 and 2, respectively). Regarding Cryptosporidium, two samples (25.0%; kit 1 and 28.5% for kit 2) were detected positive by using ECP, while for SFM, only one sample (examined by kit 1) was positive (12.5%). The results of the control trial revealed Giardia and Cryptosporidium recovery efficiency rates for ECP of 54.5% and 9.6%, while SFM was 10.5% and 3.2%, respectively. Considering the high concentration detected, a previous evaluation of the activated sludge before its application in agriculture is recommended and with some improvement, ECP would be an appropriate simple technique for protozoa detection in sewage samples.
Resumo:
The objective of this work was to evaluate the effect of pond management on fish feed, growth, yield, survival, and water and effluent quality, during tambaqui (Colossoma macropomum) juvenile production. Fish were distributed in nine 600 m² earthen ponds, at a density of 8 fish per m²; the rearing period was 60 days. Three different pond management were applied: limed and fertilized (LimFer), limed (Lim), and natural (Nat). Fish were fed with a commercial ration containing 34% crude protein three times daily. There were no significant differences in fish growth or yield. Three main items found in tambaqui stomach were insect, zooplankton and ration, without a significant difference among treatments in proportion. Alkalinity, hardness, and CO2 were greater in LimFer and Lim ponds. Chlorophyll a, transparency, ammonia, nitrite, temperature, and dissolved oxygen of pond water were not significantly different among treatments. Biochemical oxygen demand, total phosphorus, orthophosphate, ammonia, and nitrite were significantly greater in effluents from LimFer ponds. Pond fertilization should be avoided, because growth and yield were similar among the three pond management systems tested; besides, it produces a more impacting effluent.
Resumo:
The contribution of the industrial activities to the environmental contamination phenomena is evident. Great efforts are dedicated to the establishment of methodologies which permits an adequate treatment of the produced effluents, as a manner of minimizing the environmental impact of these wastes. The methodologies based on photocatalytic processes are very promise alternatives, because permits degradation of a great number of chemical substances of high toxic potential, without the use of other chemicals. The present work is an overview about the principal environmental aspects related with the paper and cellulose industry and the main alternatives employed for the reduction of environmental impact produced for its residues. The principal results of the photocatalytic treatment of this kind of effluents using metallic semiconductors is also showed.
Resumo:
Metabolic rates were determined by dissolved oxigen changes in light and dark bottles, filled with river water and after input of mixed effluent concentrations. In another experiment, dissolved inorganic nutrients, chlorophyll-alpha and other physico-chemical parameters were analyzed. Water column showed higher decomposition than production rates. Waste inputs increased primary production rates, but in higher concentrations forced the system to heterotrophy. The natural richness of macrophytes and macroalgae could be limiting the phytoplanktonic production by phosphorus assimilation. Observation of the nitrogenated inorganic nutrients suggest that the natural pelagic system is directed to nitrification. Mixed waste input inverted this trend, toward denitrification.
Resumo:
The toxic character of organochloride compounds, their habitual presence in many industrial effluents, and mainly the low efficiency of the current remediation processes, are important aspects that have been promoted to study new degrading technologies. Among the great number of new physical and chemical alternatives, the photochemical and electrochemical processes have been played an important role, mainly due to their high degradation capacity through relatively low-cost procedures. In these contexts biological processes, the use of white-rot fungi, or even ligninolytic enzymes produced from them, are also very promising alternatives. However, the necessity of long reaction time and the high cost of the enzyme production process are some of the drawbacks that difficult the definitive consolidation of these processes.
Resumo:
Textile effluents, when not correctly treated, cause a high impact to the environment. The main recalcitrant compounds present in textile effluent are represented by the synthetic dyes, used during the fibber dying process. Among others, the azo dyes are considered the most harmful due to its mutagenic and carcinogenic character. In the present work we reported a revision study on the new tendencies for remediation of textile effluents, mainly to degrade the recalcitrant compounds. For this purpose, chemical, physical, photochemical, biological and combined processes were investigated.
Resumo:
Fluoride concentration was determined in rainwater, ground water and soil in the zone of fertilizer industry in the city of Rio Grande. In contaminated rainwater fluorine concentration was registered up to the value of 4,4 mg.L-1. Fluorine concentration in the shallow ground water in general reflects its distribution in the atmosphere, but cannot be used as marker of atmosphere contamination in the urban area due to dissolving influence of residential effluents. The 0,01% HCl extracts from the set of surface soil samples demonstrates fluoride distribution in the zone of influence of industrial emissions, which coincides to the numerical simulation of fluorides dispersion in the air.
Resumo:
Organic compounds responsible for the color of wastewaters are usually refractory to biological digestion. In this paper the photo-assisted electrolysis process is used for color removal from three of the most colored wastewaters, which are daily generated in large amounts: the E1 bleach Kraft mill effluent, a textile reactive dye effluent and a landfill leachate. Electrolysis was carried out at 26,5 mA cm-2 in a flow reactor in which the anode surface was illuminated by a 400 W high pressure Hg bulb. In all experiments 70-75% of color reduction was observed which was also followed by a net organic load oxidation.
Resumo:
The abatement of recalcitrant lignin macromolecules from effluents of pulp and paper industry was investigated by combined process. Flocculation and coagulation with aluminum sulfate and natural polyelectrolytes extracted from cactus Cereus peruvianus were used in the first step. After separation of solid residues by filtration, the photochemical methods using TiO2 as catalyst were employed for photocatalytic degradation of lignin compounds from solution. The abatement of lignin compounds after flocculation and coagulation was 46%, and after the overall process, the pollutants reduction observed were 66%. The remaining organic compounds may be removed by any biological treatment.
Resumo:
Coal ashes produced in coal-fired power plant could be converted into zeolites and can be used as low-cost adsorbents for the treatment of effluents contaminated with high levels of toxic metals. The capacity of synthetic zeolites for the removal of cadmium, zinc and copper ions from aqueous solutions has been investigated under different operating conditions. Zeolite from bottom chimney showed higher removal efficiency for metals ions than zeolite from feed hopper and mixing mill. The results indicated that the treated bottom ash could be applied in environmental technology as an immobilizer of pollutants.
Resumo:
A system for disposal and recovery of the main effluents and chemical waist from isotope separation plants and enriched compounds-15N and 34S production has been carried out at the Stable Isotope Laboratory (LIE) of the CENA/USP. Around four hundred thousand liters of effluents has been recovered yearly. Among the recovered chemical wastes, the more relevant are: ammonia; brome; ammonium and sodium sulfate; sodium hydroxide; sulfur dioxide; and hydrochloric acid. Chemical wastes containg recoverable heavy metals (Ag, Cr and Cu) and solvents (methanol, ethanol and acetone) are processed and recovered. Gaseous emissions, mainly H2S are used for recovery of heavy metals solutions. The minimization of the residues waters, as well the reduction of electric energy consume was established using a water deionization system. A cost/effect balance of the process is reported.
Resumo:
Heavy-metal concentration in sediment is an important parameter for identifying pollution sources and assessing pollution levels in aquatic ecosystems. In this context, the present study aimed at determining concentrations of heavy metals in sediments from the Vitória estuarine system, Brazil. Twenty nine stations were surveyed to assess the spatial distribution of heavy metals. The metals for silt-clay fractions (<63 µm) were analyzed through atomic absorption spectrometry. A discriminant analysis segregated the stations in four groups representing four areas within the estuarine system. The Espírito Santo Bay showed the lowest metal concentrations, while the Vitória harbor canal showed the highest. We concluded that concentrations of heavy metals reflect natural conditions and the contribution of human activities from sewage and industrial effluents. It was not possible to directly associate metal concentrations to specific pollution sources.