88 resultados para Rectangular Pressure Pulse
em Scielo Saúde Pública - SP
Resumo:
OBJECTIVE: To evaluate elastic properties of conduit arteries in asymptomatic patients who have severe chronic aortic regurgitation. METHODS: Twelve healthy volunteers aged 30±1 years (control group) and 14 asymptomatic patients with severe aortic regurgitation aged 29±2 years and left ventricular ejection fraction of 0.61±0.02 (radioisotope ventriculography) were studied. High-resolution ultrasonography was performed to measure the systolic and diastolic diameters of the common carotid artery. Simultaneous measurement of blood pressure enabled the calculation of arterial compliance and distensibility. RESULTS: No differences were observed between patients with aortic regurgitation and the control group concerning age, sex, body surface, and mean blood pressure. Pulse pressure was significantly higher in the aortic regurgitation group compared with that in the control group (78±3 versus 48±1mmHg, P<0.01). Arterial compliance and distensibility were significantly greater in the aortic regurgitation group compared with that in the control group (11.0±0.8 versus 8.1±0.7 10-10 N-1 m4, P=0.01 e and 39.3±2.6 versus 31.1±2.0 10-6 N-1 m², P=0.02, respectively). CONCLUSION: Patients with chronic aortic regurgitation have increased arterial distensibility. Greater vascular compliance, to lessen the impact of systolic volume ejected into conduit arteries, represents a compensatory mechanism in left ventricular and arterial system coupling.
Resumo:
The Bartlett-Lewis Rectangular Pulse Modified (BLPRM) model simulates the precipitous slide in the hourly and sub-hourly and has six parameters for each of the twelve months of the year. This study aimed to evaluate the behavior of precipitation series in the duration of 15 min, obtained by simulation using the model BLPRM in situations: (a) where the parameters are estimated from a combination of statistics, creating five different sets; (b) suitability of the model to generate rain. To adjust the parameters were used rain gauge records of Pelotas/RS/Brazil, which statistics were estimated - mean, variance, covariance, autocorrelation coefficient of lag 1, the proportion of dry days in the period considered. The results showed that the parameters related to the time of onset of precipitation (λ) and intensities (μx) were the most stable and the most unstable were ν parameter, related to rain duration. The BLPRM model adequately represented the mean, variance, and proportion of the dry period of the series of precipitation lasting 15 min and, the time dependence of the heights of rain, represented autocorrelation coefficient of the first retardation was statistically less simulated series suitability for the duration of 15 min.
Resumo:
Left ventricular hypertrophy following volume overload is regarded as an example of cardiac remodeling without increased fibrosis accumulation. However, infarction is associated with increased fibrosis within the noninfarcted, hypertrophied myocardium, particularly in the subendocardial regions. It is conceivable to suppose that, as also occurs postinfarction, low coronary driving pressure may also interfere with accumulation of myocardial fibrosis following aortocaval fistula. PURPOSE: To investigate the role of acute hemodynamic changes in subsequent deposition of cardiac fibrosis in response to aortocaval fistula. METHOD: Aortocaval fistula were created in 4 groups of Wistar rats that were followed over 4 and 8 weeks: aortocaval fistula 4 and aortocaval fistula 8 (10 rats each) and their respective controls (sham-operated controls - Sh), Sh4 and Sh8 (8 rats each). Hemodynamic measurements were performed 1 week after surgery. Hypertrophy and fibrosis were quantified by myocyte diameter and collagen volume fraction at the end of follow up. RESULT: Compared with Sh4 and Sh8, pulse pressure, left ventricular end-diastolic pressure, and +dP/dt were higher in aortocaval fistula 4 and aortocaval fistula 8, but -dP/dt was similar. Coronary driving pressure (mm Hg), used as an estimate of perfusion pressure, was lower in aortocaval fistula 8 (52.6 ± 4.1) than in Sh8 (100.8 ± 1.3), but comparable between aortocaval fistula 4 (50.0 ± 8.9) and Sh4 (84.8 ± 2.3). Myocyte diameter was greater in aortocaval fistula 8, whereas interstitial and subendocardial fibrosis were greater in aortocaval fistula 4 and aortocaval fistula 8. Coronary driving pressure correlated inversely and independently with subendocardial fibrosis (r² = .86, P <.001), whereas left ventricular systolic pressure (r² = 0.73, P = .004) and end-diastolic pressure (r² = 0.55, P = 012) correlated positively and independently with interstitial fibrosis. CONCLUSION: Coronary driving pressure falls and ventricular pressures increase early after aortocaval fistula and are associated with subsequent myocardial fibrosis deposition.
Resumo:
Abstract Casual blood pressure measurements have been extensively questioned over the last five decades. A significant percentage of patients have different blood pressure readings when examined in the office or outside it. For this reason, a change in the paradigm of the best manner to assess blood pressure has been observed. The method that has been most widely used is the Ambulatory Blood Pressure Monitoring - ABPM. The method allows recording blood pressure measures in 24 hours and evaluating various parameters such as mean BP, pressure loads, areas under the curve, variations between daytime and nighttime, pulse pressure variability etc. Blood pressure measurements obtained by ABPM are better correlated, for example, with the risks of hypertension. The main indications for ABPM are: suspected white coat hypertension and masked hypertension, evaluation of the efficacy of the antihypertensive therapy in 24 hours, and evaluation of symptoms. There is increasing evidence that the use of ABPM has contributed to the assessment of blood pressure behaviors, establishment of diagnoses, prognosis and the efficacy of antihypertensive therapy. There is no doubt that the study of 24-hour blood pressure behavior and its variations by ABPM has brought more light and less darkness to the field, which justifies the title of this review.
Resumo:
The objective of the present work is the experimental determination of pressure drop coefficients (loss coefficients) for elliptic and circular sections in one, two and three-row arrangements of plate fin and tube heat exchangers. The experiments permitted to correlate the dimensionless loss coefficient with the flow Reynolds number in the rectangular channel formed by the plate fins. The experimental technique consisted of the measurement of the longitudinal pressure distribution along the flow channel, for several values of air mass flow rate. The total number of data runs, each one characterized by the flow Reynolds number, was 216. The present geometry is used in compact heat exchangers for air conditioning systems, heaters, radiators, and others. Also, it is verified the influence of the utilization of elliptic tubes, instead of circular ones, in the pressure drop. The measurements were performed for Reynolds numbers ranging from 200 to 1900.
Resumo:
Pulse Response Based Control (PRBC) is a recently developed minimum time control method for flexible structures. The flexible behavior of the structure is represented through a set of discrete time sequences, which are the responses of the structure due to rectangular force pulses. The rectangular force pulses are given by the actuators that control the structure. The set of pulse responses, desired outputs, and force bounds form a numerical optimization problem. The solution of the optimization problem is a minimum time piecewise constant control sequence for driving the system to a desired final state. The method was developed for driving positive semi-definite systems. In case the system is positive definite, some final states of the system may not be reachable. Necessary conditions for reachability of the final states are derived for systems with a finite number of degrees of freedom. Numerical results are presented that confirm the derived analytical conditions. Numerical simulations of maneuvers of distributed parameter systems have shown a relationship between the error in the estimated minimum control time and sampling interval
Resumo:
This work analyzes an active fuzzy logic control system in a Rijke type pulse combustor. During the system development, a study of the existing types of control for pulse combustion was carried out and a simulation model was implemented to be used with the package Matlab and Simulink. Blocks which were not available in the simulator library were developed. A fuzzy controller was developed and its membership functions and inference rules were established. The obtained simulation showed that fuzzy logic is viable in the control of combustion instabilities. The obtained results indicated that the control system responded to pulses in an efficient and desirable way. It was verified that the system needed approximately 0.2 s to increase the tube internal pressure from 30 to 90 mbar, with an assumed total delay of 2 ms. The effects of delay variation were studied. Convergence was always obtained and general performance was not affected by the delay. The controller sends a pressure signal in phase with the Rijke tube internal pressure signal, through the speakers, when an increase the oscillations pressure amplitude is desired. On the other hand, when a decrease of the tube internal pressure amplitude is desired, the controller sends a signal 180º out of phase.
Resumo:
Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.
Resumo:
Marfan syndrome (MS) is a dominant autosomal disease caused by mutations in chromosome 15, the locus controlling fibrillin 1 synthesis, and may exhibit skeletal, ocular, cardiovascular, and other manifestations. Pulse wave velocity (PWV) is used to measure arterial elasticity and stiffness and is related to the elastic properties of the vascular wall. Since the practice of exercise is limited in MS patients, it was of interest to analyze the acute effect of submaximal exercise on aortic distensibility using PWV and other hemodynamic variables in patients with MS with either mild or no aortic dilatation. PWV and physiological variables were evaluated before and after submaximal exercise in 33 patients with MS and 18 controls. PWV was 8.51 ± 0.58 at rest and 9.10 ± 0.63 m/s at the end of exercise (P = 0.002) in the group with MS and 8.07 ± 0.35 and 8.98 ± 0.56 m/s in the control group, respectively (P = 0.004). Comparative group analysis regarding PWV at rest and at the end of exercise revealed no statistically significant differences. The same was true for the group that used β-blockers and the one that did not. The final heart rate was 10% higher in the control group than in the MS group (P = 0.01). Final systolic arterial pressure was higher in the control group (P = 0.02). PWV in MS patients with mild or no aortic dilatation did not differ from the control group after submaximal effort.
Resumo:
The present study was conducted to obtain reference values for brachial-ankle pulse wave velocity (baPWV) and to evaluate influencing factors of baPWV according to gender. Using automatic devices, baPWV was measured simultaneously in 2095 subjects. A total of 647 healthy subjects, none of whom presented atherosclerotic risk factors, were analyzed in the present study. Two different statistical methods were used to obtain reference values for baPWV according to subject gender and age. The association between baPWV value and gender, as well as other features, were analyzed. For male subjects, multiple stepwise analysis showed that age, systolic blood pressure (SBP), heart rate (HR), and plasma levels of triglycerides (TG) were independent predictors of baPWV. For female subjects, age, SBP, HR, and plasma levels of uric acid (UA) were independent predictors of baPWV. In male subjects, the upper limits of baPWV values were 1497.43/1425.00, 1518.67/1513.25, 1715.97/1726.50, 1925.20/1971.90, and 2310.18/2115.00 cm/s, obtained using two different statistical methods for the age ranges of 30-39, 40-49, 50-59, 60-69, and 70 and older, respectively. For females, the upper limits of baPWV values were 1426.70/1411.13, 1559.15/1498.95, 1733.50/1739.00, 1958.63/1973.78, and 2720.80/2577.00 cm/s for the age ranges of 30-39, 40-49, 50-59, 60-69, and 70 and older, respectively. Aging is the most important influencing factor for baPWV value and its effect is more prominent in females. The reference values of baPWV according to age and gender may be useful for the clinical diagnosis and preventive therapy of cardiovascular diseases.
Resumo:
Accumulating evidence has suggested that high salt and potassium might be associated with vascular function. The aim of this study was to investigate the effect of salt intake and potassium supplementation on brachial-ankle pulse wave velocity (PWV) in Chinese subjects. Forty-nine subjects (28-65 years of age) were selected from a rural community of northern China. All subjects were sequentially maintained on a low-salt diet for 7 days (3.0 g/day NaCl), a high-salt diet for an additional 7 days (18.0 g/day NaCl), and a high-salt diet with potassium supplementation for a final 7 days (18.0 g/day NaCl+4.5 g/day KCl). Brachial-ankle PWV was measured at baseline and on the last day of each intervention. Blood pressure levels were significantly increased from the low-salt to high-salt diet, and decreased from the high-salt diet to high-salt plus potassium supplementation. Baseline brachial-ankle PWV in salt-sensitive subjects was significantly higher than in salt-resistant subjects. There was no significant change in brachial-ankle PWV among the 3 intervention periods in salt-sensitive, salt-resistant, or total subjects. No significant correlations were found between brachial-ankle PWV and 24-h sodium and potassium excretions. Our study indicates that dietary salt intake and potassium supplementation, at least in the short term, had no significant effect on brachial-ankle PWV in Chinese subjects.
Resumo:
The purpose of this study was to evaluate and establish the mean values of IOP in healthy adult sheep using an applanation tonometer. Information on age, sex, and breed was obtained for all animals included in this study. Twenty five healthy sheep (Ovis aries), of the same breed (Texel), male or female, with three years of age, received an ophthalmic examination in both eyes, including pupillary reflexes, Schirmer tear test, slit lamp biomicroscopy, and fluorescein staining. For all ophthalmic testing, animals were gently physically restrained, with no pressure in the jugular area and the eyelids were carefully open. IOP was measured by applanation tonometry (Tonopen XL). The same examiner performed the tonometry; measurements were taken three times for each eye, and their average was recorded as the IOP of the animal. Statistical analysis was performed using paired t-test and values of P < 0.05 were considered significant. The mean intraocular pressure in the whole group of 50 eyes was of 16.36 +/- 2.19 mm Hg. The mean (SD) IOP in the right eye was of 15.96 +/- 2.02 mm Hg, while the mean (SD) IOP in the left eye was of 16.76 +/- 2.32 mm Hg. Significant differences in IOP were not found between right and left eyes. The applanation tonometer was adequate for measuring the intraocular pressure in sheep. Reference data will assist in diagnosing testing for ophthalmic disease in sheep, as¹ well as promote further studies in this area.
Resumo:
^len^lpt^aOBJETIVO: Descrever a prevalência de pressão arterial limítrofe (PAL) e hipertensão (HT) entre adultos jovens e avaliar a associação entre tamanho ao nascer e PAL/HT. MÉTODOS: Dados foram coletados do primeiro estudo brasileiro de coorte de nascimentos em Ribeirão Preto (sudeste do Brasil), iniciado em 1978/79. De 6.827 recém-nascidos de parto único hospitalar, 2.060 foram avaliados aos 23/25 anos. Foram realizadas coleta de sangue, avaliação antropométrica e obtidas informações sobre ocupação, escolaridade, hábitos de vida e doenças crônicas. Pressão arterial (PA) foi classificada em: 1) PAL: PA sistólica (PAS) ≥ 130 e < 140 mm Hg e/ou PA diastólica (PAD) ≥ 85 e < 90 mmHg; 2) HT: PAS ≥ 140 e/ou PAD ≥ 90 mm Hg. Foi aplicado modelo de regressão logística politômica. RESULTADOS: A prevalência de PAL foi de 13,5% (homens 23,2%) e a de HT, 9,5% (homens 17,7%). PAL foi independentemente associada com sexo masculino (RR 8,84; IC95%: 6,09;12,82), comprimento ao nascer ≥ 50 cm (RR 1,97; 1,04; 3,73), índice de massa corporal (IMC) ≥ 30 kg/m² (RR 3,23; 2,02; 5,15) e circunferência de cintura alterada (RR 1,61; 1,13;2,29), enquanto HT associou-se com sexo masculino (RR 15,18; 8,92;25,81), IMC ≥ 30 kg/m² (RR 3,68; 2,23;6,06), circunferência de cintura alterada (RR 2,68; 1,77;4,05) e glicemia elevada (RR 2,55; 1,27;5,10), mas não com comprimento ao nascer. CONCLUSÕES: As prevalências de PAL e HT entre os adultos jovens dessa coorte foram maiores em homens que em mulheres. Maior comprimento ao nascer foi associado com PAL, mas não com HT, enquanto peso ao nascer não foi associado com PAL ou HT. Fatores de risco do adulto explicaram a maioria dos aumentos de PAL ou HT.^les^aOBJETIVO: Describir la prevalencia de presión arterial limítrofe (PAL) e hipertensión (HT) entre adultos jóvenes y evaluar la asociación entre tamaño al nacer y PAL/HT. MÉTODOS: : Los datos fueron colectados en el primer estudio de cohorte de nacimientos brasileño en Ribeirao Preto (sureste de Brasil), iniciado en 1978/79. De 6.827 recién nacidos de parto único hospitalario, 2.060 fueron evaluados a los 23/25 años. Se realizaron colecta de sangre, evaluación antropométrica y obtenidas informaciones sobre ocupación, escolaridad, hábitos de vida y enfermedades crónicas. Presión arterial (PA) fue clasificada en: 1) PAL: PA sistólica (PAS) ≥ 130 y < 140 mm Hg y/o PA diastólica (PAD) ≥ 85 y < 90 mm Hg; 2) HT: PAS ≥ 140 y/o PAD ≥ 90 mm Hg. Se aplicó modelo de regresión logística politómica. RESULTADOS: La prevalencia de PAL fue de 13,5% (hombres 23,2%) y la de HT, 9,5% (hombres 17,7%). PAL fue independientemente asociada con sexo masculino (Riesgo Relativo - RR) 8,84; 95%IC: 6,09;12,82), estatura al nacer ≥ 50 cm (RR 1,97; 1,04; 3,73), índice de masa corporal (IMC) ≥ 30 kg/m2 (RR 3,23; 2,02; 5,15) y circunferencia de cintura alterada (RR 1,61; 1,13;2,29), mientras el HT se asoció con sexo masculino (RR 15,18; 8,92;25,81), IMC ≥ 30 kg/m2 (RR 3,68; 2,23;6,06), circunferencia de cintura alterada (RR 2,68; 1,77;4,05) y glicemia elevada (RR 2,55; 1,27;5,10), pero no con estatura al nacer. CONCLUSIONES: Las prevalencias de PAL y HT entre los adultos jóvenes de la cohorte fueron mayores en hombres que en mujeres. Mayor estatura al nacer fue asociado con PAL, pero no con HT, mientras que el peso al nacer no estuvo asociado con PAL o HT. Factores de riesgo de adulto explicaron la mayoría de los aumentos de PAL o HT.
Resumo:
OBJECTIVE To analyze the factors associated with stiffness of the great arteries in prepubertal children.METHODS This study with convenience sample of 231 schoolchildren aged 9-10 years enrolled in public and private schools in Vitória, ES, Southeastern Brazil, in 2010-2011. Anthropometric and hemodynamic data, blood pressure, and pulse wave velocity in the carotid-femoral segment were obtained. Data on current and previous health conditions were obtained by questionnaire and notes on the child’s health card. Multiple linear regression was applied to identify the partial and total contribution of the factors in determining the pulse wave velocity values.RESULTS Among the students, 50.2% were female and 55.4% were 10 years old. Among those classified in the last tertile of pulse wave velocity, 60.0% were overweight, with higher mean blood pressure, waist circumference, and waist-to-height ratio. Birth weight was not associated with pulse wave velocity. After multiple linear regression analysis, body mass index (BMI) and diastolic blood pressure remained in the model.CONCLUSIONS BMI was the most important factor in determining arterial stiffness in children aged 9-10 years.