21 resultados para Reconstructive dosimetry

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

According to the International Atomic Energy Agency (IAEA), a relatively significant number of radiological accidents have occurred in recent years mainly because of the practices referred to as potentially high-risk activities, such as radiotherapy, large irradiators and industrial radiography, especially in gammagraphy assays. In some instances, severe injuries have occurred in exposed persons due to high radiation doses. In industrial radiography, 80 cases involving a total of 120 radiation workers, 110 members of the public including 12 deaths have been recorded up to 2014. Radiological accidents in industrial practices in Brazil have mainly resulted in development of cutaneous radiation syndrome (CRS) in hands and fingers. Brazilian data include 5 serious cases related to industrial gammagraphy, affecting 7 radiation workers and 19 members of the public; however, none of them were fatal. Some methods of reconstructive dosimetry have been used to estimate the radiation dose to assist in prescribing medical treatment. The type and development of cutaneous manifestations in the exposed areas of a person is the first achievable gross dose estimation. This review article presents the state-of-the-art reconstructive dosimetry methods enabling estimation of local radiation doses and provides guidelines for medical handling of the exposed individuals. The review also presents the Chilean and Brazilian radiological accident cases to highlight the importance of reconstructive dosimetry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To study whether endarterectomy is feasible in all patients with aortofemoral atherosclerotic obstruction, considering early and late results. METHODS: A clinical, prospective, and descriptive study carried out in a university hospital. Inclusion criteria were atherosclerotic aortofemoral obstructive disease, clinical status compatible with major surgery, and absence of prior restorative procedure. Exclusion criteria were aneurysm, inflammatory arterial disease, and prior restorative procedure found during surgery. Eighty patients entered the protocol, but 9 were excluded (11.2%). Seventy-one patients, mean age of 57.3 years, underwent endarterectomy. Operative indications were intermittent claudication and critical ischemia. A ring-stripper endarterectomy technique was employed in all patients. Results were related to age, gender, symptoms, presence of diabetes mellitus, extension of endarterectomy, and extent of obstructive disease. Chi square or Fisher exact tests were used when appropriate, and the Wilkoxon (Gehan) test was used to compare survival curves. RESULTS: Sixty-eight (100%) endarterectomies were patent at discharge. The mortality rate was 4.2%. The amputation rate (4.3%) was higher in diabetic patients and when there was associated femoropopliteal obstruction. The 5-year survival rate was 83.3%, and late deaths were mostly cardiovascular. Diabetes mellitus, age above 65 years, and associated femoropopliteal obstruction lowered the survival rate. The 5-year patency rate was 87.0%. Critical ischemia and less extensive endarterectomies were associated with a lower patency rate. There were no anastomotic aneurysms or deep infections. CONCLUSIONS: Aortofemoral thromboendarterectomy is feasible in 90% of patients, early mortality rate is low, diabetic patients and those with associated femoropopliteal obstructive disease have a higher mortality rate, amputation rate is low, late deaths are mostly cardiovascular, and late patency rate is high, and even higher in the intermittent claudication group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to evaluate the degree of metastatic bone pain palliation and medullar toxicity associated with samarium-153-EDTMP treatment. METHODS: Seventy-three patients with metastatic bone pain having previously undergone therapy with samarium-153-EDTMP (1 mCi/kg) were retrospectively evaluated. Routine follow-up included pain evaluation and blood counts for 2 months after treatment. Pain was evaluated using a subjective scale (from 0 to 10) before and for 8 weeks after the treatment. Blood counts were obtained before treatment and once a week for 2 months during follow-up. Dosimetry, based upon the urinary excretion of the isotope, was estimated in 41 individuals, and the resulting radiation absorbed doses were correlated with hematological data. RESULTS: Reduction in pain scores of 75% to 100% was obtained in 36 patients (49%), with a decrease of 50% to 75%, 25% to 50%, and 0% to 25% in, respectively, 20 (27%), 10 (14%), and 7 (10%) patients. There was no significant relationship between the pain response and location of the primary tumor (breast or prostate cancer). Mild to moderate myelosuppression was noted in 75.3% of patients, usually with hematological recovery at 8 weeks. The mean bone marrow dose was 347 ± 65 cGy, and only a weak correlation was found between absorbed dose and myelosuppression (Pearson coefficient = .4). CONCLUSIONS: Samarium-153-EDTMP is a valuable method for metastatic bone pain palliation. A mild to moderate and transitory myelosuppression is the main toxicity observed after samarium therapy, showing a weak correlation with dosimetric measures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Left ventricular aneurysm is a complication of myocardial infarction that can best be treated by reconstructive surgeries that can restore ventricular geometry. We analyzed immediate results in a group of consecutive patients who underwent surgical correction of left ventricular aneurysms. METHODS: From January '90 to August '99, 94 patients - mean age 58.4 (ranging from 36 to 73 years), 65 (69.1%) males and 9 ( 30.8%) females - were operated upon. Pre-operative ejection fraction ranged from 0.22 to 0.58 (mean = 0.52), and the aneurysm was located in the antero-lateral area in 90.4% of the cases. Functional class III and IV (NYHA) was present in 82 (87.2%) patients, and 12 (12.7%) were in functional class I and II. Congestive heart failure was the most frequent cause (77.6%), occurring in isolation in 24.4% or associated with coronary artery diseases in 53.2%. RESULTS: Short-term follow-up showed a 7.4% mortality, and low cardiac output was the main cause of death. Coming off pump was uneventful in 73 patients (77.6%), with a 3.2% mortality and with the use of inotropics in 20 (21.3%). One patient (1%) did not come off the pump. CONCLUSION: Surgical correction was adequate in the immediate follow-up of operated patients, and mortality was higher in patients with higher functional class.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze late clinical evolution after surgical treatment of children, with reparative and reconstructive techniques without annular support. METHODS: We evaluated 21 patients operated upon between 1975 and 1998. Age 4.67±3.44 years; 47.6% girls; mitral insufficiency 57.1% (12 cases), stenosis 28.6% (6 cases), and double lesion 14.3% (3 cases). The perfusion 43.10±9.50min, and ischemia time were 29.40±10.50min. The average clinical follow-up in mitral insufficiency was 41.52±53.61 months. In the stenosis group (4 patients) was 46.39±32.02 months, and in the double lesion group (3 patients), 39.41±37.5 months. The echocardiographic follow-up was in mitral insufficiency 37.17±39.51 months, stenosis 42.61±30.59 months, and in the double lesion 39.41±37.51 months. RESULTS: Operative mortality was 9.5% (2 cases). No late deaths occurred. In the group with mitral insufficiency, 10 (83.3%) patients were asymptomatic (p=0.04). The majorit y with mild reflux (p=0.002). In the follow-up of the stenosis group, all were in functional class I (NYHA); and the mean transvalve gradient varied between 8 and 12mmHg, average of 10.7mmHg. In the double lesion group, 1 patient was reoperated at 43 months. No endocarditis or thromboembolism were reported. CONCLUSION: Mitral stenosis repair has worse late results, related to the valve abnormalities and associated lesions. The correction of mitral insufficiency without annular support showed good long-term results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to determine approaches that would improve the quality of ancient DNA (aDNA) present in coprolites to enhance the possibility of success in retrieving specific sequence targets. We worked with coprolites from South American archaeological sites in Brazil and Chile dating up to 7,000 years ago. Using established protocols for aDNA extraction we obtained samples showing high degradation as usually happens with this kind of material. The reconstructive polymerization pretreatment was essential to overcome the DNA degradation and the serial dilutions helped with to prevent polymerase chain reaction (PCR) inhibitors. Moreover, the random amplified polymorphic DNA-PCR has been shown to be a reliable technique for further experiments to recover specific aDNA sequences.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective The present study was aimed at estimating the doses received by physicians and patients during cerebral angiography procedures in a public hospital of Recife, PE, Brazil. Materials and Methods The study sample included 158 adult patients, and during the procedures the following parameters were evaluated: exposure parameters (kV, mAs), number of acquired images, reference air kerma value (Ka,r) and air kerma-area product (PKA). Additionally, the physicians involved in the procedures were evaluated as for absorbed dose in the eyes, thyroid, chest, hands and feet. Results The results demonstrated that the doses to the patients' eyes region were relatively close to the threshold for cataract occurrence. As regards the physicians, the average effective dose was 2.6 µSv, and the highest effective dose recorded was 16 µSv. Conclusion Depending on the number of procedures, the doses received by the physicians may exceed the annual dose limit for the crystalline lenses (20 mSv) established by national and international standards. It is important to note that the high doses received by the physicians are due to the lack of radiation protection equipment and accessories, such as leaded curtains, screens and protective goggles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective The authors have sought to study the calibration of a clinical PKA meter (Diamentor E2) and a calibrator for clinical meters (PDC) in the Laboratory of Ionizing Radiation Metrology at Instituto de Energia e Ambiente - Universidade de São Paulo. Materials and Methods Different qualities of both incident and transmitted beams were utilized in conditions similar to a clinical setting, analyzing the influence from the reference dosimeter, from the distance between meters, from the filtration and from the average beam energy. Calibrations were performed directly against a standard 30 cm3 cylindrical chamber or a parallel-plate monitor chamber, and indirectly against the PDC meter. Results The lowest energy dependence was observed for transmitted beams. The cross calibration between the Diamentor E2 and the PDC meters, and the PDC presented the greatest propagation of uncertainties. Conclusion The calibration coefficient of the PDC meter showed to be more stable with voltage, while the Diamentor E2 calibration coefficient was more variable. On the other hand, the PDC meter presented greater uncertainty in readings (5.0%) than with the use of the monitor chamber (3.5%) as a reference.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Objective: To estimate the entrance surface air kerma (Ka,e) and air kerma in the region of radiosensitive organs in radiographs of pediatric paranasal sinuses. Materials and Methods: Patient data and irradiation parameters were collected in examinations of the paranasal sinuses in children from 0 to 15 years of age at two children's hospitals in the city of Recife, PE, Brazil. We estimated the Ka,e using the X-ray tube outputs and selected parameters. To estimate the air kerma values in the regions of the eyes and thyroid, we used thermoluminescent dosimeters. Results: The Ka,e values ranged from 0.065 to 1.446 mGy in cavum radiographs, from 0.104 to 7.298 mGy in Caldwell views, and from 0.113 to 7.824 mGy in Waters views. Air kerma values in the region of the eyes ranged from 0.001 to 0.968 mGy in cavum radiographs and from 0.011 to 0.422 mGy in Caldwell and Waters views . In the thyroid region, air kerma values ranged from 0.005 to 0.932 mGy in cavum radiographs and from 0.002 to 0.972 mGy in Caldwell and Waters views. Conclusion: The radiation levels used at the institutions under study were higher than those recommended in international protocols. We recommend that interventions be initiated in order to reduce patient exposure to radiation and therefore the risks associated with radiological examination of the paranasal sinuses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR) 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since 2000, spore dosimetry and spectral photometry have been performed in parallel at the Southern Space Observatory, São Martinho da Serra (Southern Brazil). A comparative study involving data from Punta Arenas - Chile (53.2º S), São Martinho da Serra (29.5º S), Padang - Indonesia (0.9ºS), Brussels - Belgium (50.9º N) and Kiyotake - Japan (31.9º N) from 2000 to 2006 is presented. The Spore Inactivation Doses presented the higher values in summer (973 ± 73 for Punta Arenas and 4,369 ± 202 for São Martinho da Serra, as well 1,402 ± 170 and 3,400 ± 1,674 for Brussels and Kiyotake, respectively). The simplicity, robustness and high resistance of bacterial spores makes the biosensor an potential biological tool for UV-B monitoring.