122 resultados para Rapid diagnostic test

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Rapid diagnostic tests (RDTs) may improve the early detection of visceral leishmaniasis (VL), but their real-world performance requires additional study. Therefore, we evaluated the performance of an rK39-based RDT (Kalazar Detect™) for the detection of VL in an endemic, large urban area. Methods Data were collected from a registry of rK39 RDT performed at 11 emergency care units in Belo Horizonte, Brazil, and from a national database of reportable communicable diseases of the Sistema de Informação de Agravos de Notificação (SINAN). Results The rapid rK39 test was performed in 476 patients, with 114 (23.9%) positive results. The analysis of rK39 RDT performance was based on 381 (80%) cases reported to the SINAN database, of which 145 (38.1%) were confirmed cases. Estimates for sensitivity and specificity were 72.4% (95% CI: 64.6-79%) and 99.6% (95%CI: 97.6-99.9%), respectively. Positive and negative predictive values were estimated at 99.1% (95%CI: 94.9-99.8%) and 85.5% (95%CI: 80.8-89.1%), respectively. In addition, close agreement between the rK39 RDT and indirect immunofluorescence was observed. Conclusions In summary, the rK39 RDT showed a high specificity but only moderate sensitivity. In endemic areas for VL, treatment may be considered in cases with clinical manifestations and a positive rK39 RDT, but those with a negative test should be subjected to further investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article presents an improvement to the Kato-Katz (KK) method, making it faster and more efficient for the visualisation of fertile eggs in stool samples. This modified KK method uses sodium acetate formalin as a fixative and reveals the intensity of infection in less than 1 h, reducing the diagnostic time without increasing the cost. This modified method may contribute to future epidemiological studies in both hospitals and the field due to its rapid and precise diagnostic, which allow for immediate treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A significant number of Brazilian gestational-age women are still not tested for HIV, representing a high risk of transmission to their newborns. The current study sought to identify the number of pregnant women with no previous testing or undocumented for HIV referred to the Gynecology and Obstetrics Department of a Regional Teaching Hospital and included diagnosis of HIV infection determined by a rapid test and perinatal transmission in pregnancy. Medical records of all pregnant women admitted to hospital from January 2001 to December 2005 were reviewed. Pregnant women without HIV results were submitted to a rapid HIV test. Those who tested positive were further tested by ELISA and confirmed by indirect immunofluorescence assay (IIA) or Western blot (WB). The viral load from babies born to HIV-infected mothers was assessed by bDNA. Of the 16,424 pregnant women analyzed (6.6%), 1,089 were undocumented for HIV. Eleven women were positive in rapid testing and 10 were confirmed by ELISA, IIA or WB, with 0.9% seropositivity. Mother/infant pairs received zidovudine monotherapy prophylaxis and infant viral load was lower than 50 copies/mL. A higher number of pregnant women previously tested for HIV during antenatal care was verified, compared to that obtained nationwide.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We compared the diagnostic performance characteristics of newly developed method, the rapid dipstick test, which provides colorimetric determination by developing antibody to the lactate dehydrogenase enzyme of parasites, with conventional standard thick-blood film examination. For the rapid test, OptiMAL commercial kits were used. The results were also evaluated with clinical findings from patients. The parasites were determined by microscopic examination of thick-blood films from 81 patients with vivax malaria from southeastern Anatolia, Turkey. The OptiMAL test results were found to be negative in five patients who were diagnosed clinically and through thick-film testing as having vivax malaria. There was no false positivity observed with the OptiMAL test. We concluded that this rapid malaria test has a lower level of sensitivity than the classical thick-blood-film test for malaria, but that these methods have equal specificity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to evaluate a dot-enzyme-linked immunosorbent assay (dot-ELISA) using excretory-secretory antigens from the larval stages of Toxocara canis for the diagnosis of toxocariasis. A secondary aim was to establish the optimal conditions for its use in an area with a high prevalence of human T. canis infection. The dot-ELISA test was standardised using different concentrations of the antigen fixed on nitrocellulose paper strips and increasing dilutions of the serum and conjugate. Both the dot-ELISA and standard ELISA methods were tested in parallel with the same batch of sera from controls and from individuals living in the problem area. The best results were obtained with 1.33 µg/mL of antigen, dilutions of 1/80 for the samples and controls and a dilution of 1/5,000 for the anti-human IgG-peroxidase conjugate. All steps of the procedure were performed at room temperature. The coincidence between ELISA and dot-ELISA was 85% and the kappa index was 0.72. The dot-ELISA test described here is rapid, easy to perform and does not require expensive equipment. Thus, this test is suitable for the serological diagnosis of human T. canis infection in field surveys and in the primary health care centres of endemic regions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study was carried out to evaluate the Malar-CheckTM Pf test, an immunochromatographic assay that detects Plasmodium falciparum Histidine Rich Protein II, does not require equipment, and is easy and rapid to perform. In dilution assays performed to test sensitivity against known parasite density, Malar-CheckTMwere compared with thick blood smear (TBS), the gold standard for diagnosis. Palo Alto isolate or P. falciparum blood from patients with different parasitemias was used. The average cut-off points for each technique in three independent experiments were 12 and 71 parasites/mm³ (TBS and Malar-CheckTM, respectively). In the field assays, samples were collected from patients with fever who visited endemic regions. Compared to TBS, Malar-CheckTMyielded true-positive results in 38 patients, false-positive results in 3, true-negative results in 23, and false-negative result in 1. Malar-CheckTMperformed with samples from falciparum-infected patients after treatment showed persistence of antigen up to 30 days. Malar-CheckTM should aid the diagnosis of P. falciparum in remote areas and improve routine diagnosis even when microscopy is available. Previous P. falciparum infection, which can determine a false-positive test in cured individuals, should be considered. The prompt results obtained with the Malar-CheckTM for early diagnosis could avoid disease evolution to severe cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is the report of a case of fetal tachyarrhythmia with 1:1 atrioventricular conduction detected by pre-natal echocardiography in a fetus at 25-weeks gestation. Adenosine infusion via cordocentesis was performed as a diagnostic test to differentiate between atrioventricular nodal reentrant supraventricular tachyarrhythmia and atrial flutter. After infusion, transient 2:1 atrioventricular dissociation was obtained and the diagnosis of atrial flutter was made. Transplacental therapy with digoxin and amiodarone was then successfully used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Detection of rotavirus RNA by polyacrylamide gel electrophoresis (PAGE) proved to be a highly sensitive and rapid diagnostic test. A comparison of this assay with immuno-electron microscopy (IEM) and enzyme immunoassay (EIA) in 245 faeces from children with gastroenteritis revealed complete agreement between the three assays in 238 (97.14%) samples. Among 75 samples positive in at least one of the three assays, negative results were observed in 5 (6.48%) by PAGE, in 6 (6.76%) by EIA and in none by IEM. Silver staining greatly increased the sensitivity of the PAGE assay. We conclude that although IEM remains the most sensitive and rapid rotavirus diagnostic assay, the PAGE technique has many advantages in its favour, including the non-requirement of expensive equipment, the use of only chemically defined reagents and the capacity to distinguish virus subgroup and variants and to detect non-crossreactive rotaviruses which are missed in serological assays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In occupational accidents involving health professionals handling potentially contaminated material, the decision to start or to continue prophylactic medication against infection by Human Immunodeficiency Virus (HIV) has been based on the ELISA test applied to a blood sample from the source patient. In order to rationalize the prophylactic use of antiretroviral agents, a rapid serologic diagnostic test of HIV infection was tested by the enzymatic immunoabsorption method (SUDS HIV 1+2, MUREX®) and compared to conventional ELISA (Abbott HIV-1/ HIV-2 3rd Generation plus EIA®). A total of 592 cases of occupational accidents were recorded at the University Hospital of Ribeirão Preto from July 1998 to April 1999. Of these, 109 were simultaneously evaluated by the rapid test and by ELISA HIV. The rapid test was positive in three cases and was confirmed by ELISA and in one the result was inconclusive and later found to be negative by ELISA. In the 106 accidents in which the rapid test was negative no prophylactic medication was instituted, with an estimated reduction in costs of US$ 2,889.35. In addition to this advantage, the good correlation of the rapid test with ELISA, the shorter duration of stress and the absence of exposure of the health worker to the adverse effects of antiretroviral agents suggest the adoption of this test in Programs of Attention to Accidents with Potentially Contaminated Material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the specificity of a rapid immunochromatographic test that was developed to detect antibodies against the rK39 antigen for the diagnosis of visceral leishmaniasis (VL). This evaluation was performed using sera from patients with a confirmed diagnosis of active cutaneous leishmaniasis. The sera from 272 patients with a confirmed diagnosis of localised cutaneous leishmaniasis (CL) who resided in an area endemic for Leishmania braziliensis in Brazil were obtained before the initiation of antileishmanial treatment. Kalazar Detect(r)(InBios, Seattle, WA) recombinant K39 antigen-based immunochromatographic strips were used according to the manufacturer's instructions. The test results were evaluated independently by two examiners in sequential order. The positive controls for the test included five serum samples from five patients with parasitologically confirmed diagnosis of VL caused by Leishmania infantum in Brazil. Overall, 100% of the samples obtained from patients with CL were negative, confirming the absence of a serological cross-reaction for individuals with cutaneous disease when these patients were evaluated using the rapid test. The lack of a cross-reaction in patients who were infected by parasites of the same genus highlights the specificity of the rK39 antigen for the diagnosis of VL in areas with the sympatric circulation of L. braziliensis and L. infantum.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid conglutination test (RCT) with performance comparable to the indirect fluorescent antibody technique (IFAT) was developed to detect antibodies against Babesia bigemina (B. bigemina-RCT). The B. bigemina-RCT is a sensitive, specific, economical, and rapidly performed serological test suitable for field application or minimally equipped laboratories. This test had a sensitivity of 90.9%, and specificity of 97.6%, compared to IFAT, which showed for the same parameters respectively, 98.3% and 99.7%. The early detection of anti- B. bigemina immunoglobulins by RCT in experimental infections was nearly parallel to that of IFAT. Cross reactions were observed with sera from calves experimentally infected with Babesia bovis (1.8%) and with Anaplasma marginale (1.2%). RCT antigen prepared with non parasitized erythrocytes (negative antigen) showed 1.5%, 3.5% and 2.2% of positive reactions with sera from animals experimentally infected with B. bigemina, B. bovis and A. marginale. However, none of the sera from animals of endemic areas for babesia infection resulted in positive reactions with the negative antigen. Considering these results and shelf life over six months, the B. bigemina-RCT could be used for epidemiological surveys and evaluation of control measures against this species of Babesia.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Trypanosoma cruzi infection is often not detected early on or actively diagnosed, partly because most infected individuals are either asymptomatic or oligosymptomatic. Moreover, in most places, neither blood banks nor healthcare units offer diagnostic confirmation or treatment access. By the time patients present clinical manifestations of advanced chronic Chagas disease, specific treatment with current drugs usually has limited effectiveness. Better-quality serological assays are urgently needed, especially rapid diagnostic tests for diagnosis patients in both acute and chronic phases, as well as for confirming that a parasitological cure has been achieved. Some new antigen combinations look promising and it is important to assess which ones are potentially the best, together with their requirements in terms of investigation and development. In August 2007, a group of specialized researchers and healthcare professionals met to discuss the state of Chagas infection diagnosis and to build a consensus for a plan of action to develop efficient, affordable, accessible and easy-to-use diagnostic tests for Chagas disease. This technical report presents the conclusions from that meeting.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Abstract: INTRODUCTION : Molecular analyses are auxiliary tools for detecting Koch's bacilli in clinical specimens from patients with suspected tuberculosis (TB). However, there are still no efficient diagnostic tests that combine high sensitivity and specificity and yield rapid results in the detection of TB. This study evaluated single-tube nested polymerase chain reaction (STNPCR) as a molecular diagnostic test with low risk of cross contamination for detecting Mycobacterium tuberculosis in clinical samples. METHODS: Mycobacterium tuberculosis deoxyribonucleic acid (DNA) was detected in blood and urine samples by STNPCR followed by agarose gel electrophoresis. In this system, reaction tubes were not opened between the two stages of PCR (simple and nested). RESULTS: STNPCR demonstrated good accuracy in clinical samples with no cross contamination between microtubes. Sensitivity in blood and urine, analyzed in parallel, was 35%-62% for pulmonary and 41%-72% for extrapulmonary TB. The specificity of STNPCR was 100% in most analyses, depending on the type of clinical sample (blood or urine) and clinical form of disease (pulmonary or extrapulmonary). CONCLUSIONS: STNPCR was effective in detecting TB, especially the extrapulmonary form for which sensitivity was higher, and had the advantage of less invasive sample collection from patients for whom a spontaneous sputum sample was unavailable. With low risk of cross contamination, the STNPCR can be used as an adjunct to conventional methods for diagnosing TB.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Plasmodium vivax radical cure requires the use of primaquine (PQ), a drug that induces haemolysis in glucose-6-phosphate dehydrogenase deficient (G6PDd) individuals, which further hampers malaria control efforts. The aim of this work was to study the G6PDd prevalence and variants in Latin America (LA) and the Caribbean region. A systematic search of the published literature was undertaken in August 2013. Bibliographies of manuscripts were also searched and additional references were identified. Low prevalence rates of G6PDd were documented in Argentina, Bolivia, Mexico, Peru and Uruguay, but studies from Curaçao, Ecuador, Jamaica, Saint Lucia, Suriname and Trinidad, as well as some surveys carried out in areas of Brazil, Colombia and Cuba, have shown a high prevalence (> 10%) of G6PDd. The G6PD A-202A mutation was the variant most broadly distributed across LA and was identified in 81.1% of the deficient individuals surveyed. G6PDd is a frequent phenomenon in LA, although certain Amerindian populations may not be affected, suggesting that PQ could be safely used in these specific populations. Population-wide use of PQ as part of malaria elimination strategies in LA cannot be supported unless a rapid, accurate and field-deployable G6PDd diagnostic test is made available.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

More precise and rapid diagnostic methods for American cutaneous leishmaniasis (ACL) are necessary because of the growing number of cases observed in Brazil, including the northeastern region of the State of São Paulo. We applied PCR to 54 skin or mucosal biopsies from patients with a clinical and/or laboratory diagnosis of ACL using primers 13A and 13B, with positive results being obtained for 82% of the samples. When the PCR results were compared to those of histopathological leishmania detection, PCR showed superior results with 81.5% sensitivity and 95% CI of 68.0-95.1%. The Montenegro skin test (MST) was positive in 88.7% of patients. Since MST cannot be used as a diagnostic tool in endemic areas, the present results strongly suggest the use of PCR for the etiological confirmation of ACL, with emphasis on the mucosal form.