44 resultados para Radiation dose reduction

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

AbstractObjective:To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters.Materials and Methods:Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A – 551 studies) and three months after (group B – 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDIvol per phase, mean DLP per phase, and mean DLP per scan.Results:A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDIvol per phase, DLP per phase and DLP per scan (p < 0.001).Conclusion:The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. Objectives: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). Methods: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). Results: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. Conclusions: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background:Advantages and disadvantages of ad hoc percutaneous coronary intervention have been described. However little is known about the radiation exposure of that procedure as compared with the staged intervention.Objective:To compare the radiation dose of the ad hoc percutaneous coronary intervention with that of the staged procedureMethods:The dose-area product and total Kerma were measured, and the doses of the diagnostic and therapeutic procedures were added. In addition, total fluoroscopic time and number of acquisitions were evaluated.Results:A total of 568 consecutive patients were treated with ad hoc percutaneous coronary intervention (n = 320) or staged percutaneous coronary intervention (n = 248). On admission, the ad hoc group had less hypertension (74.1% vs 81.9%; p = 0.035), dyslipidemia (57.8% vs. 67.7%; p = 0.02) and three-vessel disease (38.8% vs. 50.4%; p = 0.015). The ad hoc group was exposed to significantly lower radiation doses, even after baseline characteristic adjustment between both groups. The ad hoc group was exposed to a total dose-area product of 119.7 ± 70.7 Gycm2, while the staged group, to 139.2 ± 75.3 Gycm2 (p < 0.001).Conclusion:Ad hoc percutaneous coronary intervention reduced radiation exposure as compared with diagnostic and therapeutic procedures performed at two separate times.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of the present study was to establish the extent of in vitro radioresponse of lymphocytes among 62 healthy adults of both genders and to estimate the distribution of baseline micronuclei and radiosensitivity among individuals of the study population using the cytochalasin block micronucleus test. A younger study group consisted of 10 males (mean age, 22.4 years; range, 21-27) and 12 females (mean age, 24.8 years; range, 20-29), whereas an older study group consisted of 18 males (mean age, 35.1 years; range, 30-44) and 22 females (mean age, 38.5 years; range, 30-48). For evaluation of radiosensitivity blood samples were irradiated in vitro using 60Co g-ray source. The radiation dose employed was 2 Gy, the dose rate 0.45 Gy/min. The study revealed a significant gender effect on baseline micronuclei favoring females (Z = 3.25, P < 0.001), while yields of radiation-induced micronuclei did not differ significantly (Z = 0.56, P < 0.56) between genders. The distribution of baseline micronuclei among the individuals tested followed Poisson distribution in both study groups and in both genders, whereas the distribution of radiosensitivity among individuals of the older study group did not fulfill Poisson expectations (Kolmogorov-Smirnof test, P < 0.01). In contrast to a nonsignificant difference in radiosensitivity between males and females of the same age group (Z = 1.97, P < 0.56), a statistically significant difference in radiosensitivity between younger and older group for both genders was found (Z = 3.03, P < 0.03). Since the individuals tested were healthy, the observed variability in radiation response is considered to be an early effect of ageing.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

According to the International Atomic Energy Agency (IAEA), a relatively significant number of radiological accidents have occurred in recent years mainly because of the practices referred to as potentially high-risk activities, such as radiotherapy, large irradiators and industrial radiography, especially in gammagraphy assays. In some instances, severe injuries have occurred in exposed persons due to high radiation doses. In industrial radiography, 80 cases involving a total of 120 radiation workers, 110 members of the public including 12 deaths have been recorded up to 2014. Radiological accidents in industrial practices in Brazil have mainly resulted in development of cutaneous radiation syndrome (CRS) in hands and fingers. Brazilian data include 5 serious cases related to industrial gammagraphy, affecting 7 radiation workers and 19 members of the public; however, none of them were fatal. Some methods of reconstructive dosimetry have been used to estimate the radiation dose to assist in prescribing medical treatment. The type and development of cutaneous manifestations in the exposed areas of a person is the first achievable gross dose estimation. This review article presents the state-of-the-art reconstructive dosimetry methods enabling estimation of local radiation doses and provides guidelines for medical handling of the exposed individuals. The review also presents the Chilean and Brazilian radiological accident cases to highlight the importance of reconstructive dosimetry.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Biological dosimetry (biodosimetry) is based on the investigation of radiation-induced biological effects (biomarkers), mainly dicentric chromosomes, in order to correlate them with radiation dose. To interpret the dicentric score in terms of absorbed dose, a calibration curve is needed. Each curve should be constructed with respect to basic physical parameters, such as the type of ionizing radiation characterized by low or high linear energy transfer (LET) and dose rate. This study was designed to obtain dose calibration curves by scoring of dicentric chromosomes in peripheral blood lymphocytes irradiated in vitro with a 6 MV electron linear accelerator (Mevatron M, Siemens, USA). Two software programs, CABAS (Chromosomal Aberration Calculation Software) and Dose Estimate, were used to generate the curve. The two software programs are discussed; the results obtained were compared with each other and with other published low LET radiation curves. Both software programs resulted in identical linear and quadratic terms for the curve presented here, which was in good agreement with published curves for similar radiation quality and dose rates.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: Describe implementation of a successful program to reduce doses (cefazolin 2 to 1 g) used for antimicrobial prophylaxis. METHODS: Evaluation of an intervention program to reduce prophylactic antimicrobial doses. The intervention included weekly staff discussions, automatic dispensation of 1g-vial of cefazolin by the pharmacy unless expressly requested by surgeon and increase in post-discharge surveillance as a strategy to reassure surgeons of the safety of the reduction. In the pre and post intervention periods, a prospective study of antimicrobial consumption and surgical site infections were measured. RESULTS: There were 5,164 and 5,204 deliveries in 2001-2002 and 2003-2004, respectively; 1,524 (29.5%) and 1,363 (26%) were cesarean sections. There was a 45% decrease in cefazolin vials used on average per cesarean section (2.29 to 1.25). Patients evaluated increased from 16% to 67% and the SSI rates in both periods were 3.34% to 2.42%, respectively. CONCLUSION: An ample intervention, including administrative and educational measures, led to high compliance with dose reduction and saved more than US$4,000 in cefazolin, considered important because government reimbursement in Brazil for cesarean section is $80.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: Although various studies have been published regarding the treatment of chronic hepatitis C (CHC) with peginterferon (Peg-IFN) and ribavirin, little is known regarding the real impact of gender on the characteristics that influence the effectiveness and safety of antiviral treatment for CHC patients. The objective of this study was to evaluate the influence of gender on HCV treatment outcomes. METHODS: A retrospective analytical study was conducted among selected carriers of CHC genotype 1, who were treated with Peg-IFN α-2b at a dose of 1.5 μg/kg or Peg-IFN α-2a at a dose of 180 μg/week plus a ribavirin dose of 1,000-1,250 mg/day, according to weight, between 2001 and 2007. RESULTS: Among 181 patients undergoing treatment, the mean age was 46.4 ± 11.0 years and 46% were women. At baseline, 32% of the patients had advanced fibrosis (F3-F4 Scheuer), and 83% of the subjects had viral load > 400,000 IU/ml, without significant difference between the genders (p = 0.428 and p = 0.452, respectively). When compared with men, women had higher incidence of many adverse events such as anemia (p < 0.001) and higher need for dose reduction, for both Peg-IFN (p = 0.004) and ribavirin (p = 0.006). However, the rate of sustained virological response (SVR) did not differ between the genders: 45% (female) vs 41% (male); p=0.464. CONCLUSIONS: This study suggests that women and men react differently to combined therapy, especially in relation to the incidence of adverse events and the need for dose modification. Nevertheless, these differences do not influence the SVR rate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We examined the radioprotective effect of aminothiol 2-N-propylamine-cyclo-hexanethiol (20-PRA) on a human leukemic cell line (K562) following various radiation doses (5, 7.5 and 20 Gy) using a source of 60Co g-rays. At 5 Gy and 1 nM 20-PRA, a substantial protective effect (58%) was seen 24 h after irradiation, followed by a decrease at 48 h (11%). At the high radiation dose (20 Gy) a low protective effect was also seen (35%). In addition, the antitumorigenic potential of 10 nM 20-PRA was shown by the inhibition of crown gall formation induced by Agrobacterium tumefaciens. The radioprotective potency of 20-PRA is 105-106 times higher than that of the aminothiol WR-1065 (N-(2-mercaptoethyl)-1,3-diaminopropane) whose protective effect is in the 0.1 to 1.0 mM range.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

AbstractObjective:In the present study, the authors investigated the in vitrobehavior of radio-resistant breast adenocarcinoma (MDA-MB-231) cells line and radiosensitive peripheral blood mononuclear cells (PBMC), as a function of different radiation doses, dose rates and postirradiation time kinetics, with a view to the interest of clinical radiotherapy.Materials and Methods:The cells were irradiated with Co-60, at 2 and 10 Gy and two different exposure rates, 339.56 cGy.min–1 and the other corresponding to one fourth of the standard dose rates, present over a 10-year period of cobalt therapy. Post-irradiation sampling was performed at pre-established kinetics of 24, 48 and 72 hours. The optical density response in viability assay was evaluated and a morphological analysis was performed.Results:Radiosensitive PBMC showed decrease in viability at 2 Gy, and a more significant decrease at 10 Gy for both dose rates. MDAMB- 231 cells presented viability decrease only at higher dose and dose rate. The results showed MDA-MB-231 clone expansion at low dose rate after 48–72 hours post-radiation.Conclusion:Low dose rate shows a possible potential clinical impact involving decrease in management of radio-resistant and radiosensitive tumor cell lines in cobalt therapy for breast cancer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT The objective of this study was to evaluate the effect of growth reducer and nitrogen fertilization on morphological variables, SPAD index, radiation interception, and grain yield of three cultivars of wheat. The experimental design was a randomized block in factorial scheme 3x5x2, with three cultivars (Mestre, Iguaçú and Itaipú), five nitrogen doses (0, 40, 80, 120, 160 Kg ha-1), and application or no application of a growth reducer, with three replications. The following characteristics were evaluated: plant height, SPAD index, leaf area index (LAI), Global Radiation Interception (GRI) and grain yield. The Tukey test (p < 0.05) was used for the comparison between the means of cultivar and growth reducer factors, and for a regression analysis to evaluate N levels. Increasing the dose of nitrogen promotes an increase in LAI of plants of wheat crops differently among cultivars, which leads to a greater degree of global radiation interception. At doses higher or equal to 120 Kg ha-1 of nitrogen, there are significant differences in grain yield between treatments with and without the application of the growth reducer. The significant interaction between growth reducer and nitrogen dose, showed that applications of growth reducer increase the GRI at doses above and below 80 Kg ha-1 of nitrogen. Nitrogen rates of 138 and 109 Kg ha-1 are responsible for maximum grain yields of wheat, which is 4235 and 3787 Kg ha-1 with and without the use of growth reducer, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Decreased responses to hepatitis B vaccine have been associated with some host conditions including obesity. Susceptible non-responders to a primary three-dose vaccine series should be revaccinated. Those who maintain a non-responder condition after revaccination with three vaccine doses are unlikely to develop protection using more doses. This is a description of an obese woman who received six doses of hepatitis B vaccine and persisted as a non-responder. She was submitted to a vertical banded gastroplasty Roux-en-Y gastric bypass Capellas's technique. After weight reduction, she received three additional doses of vaccine and seroconverted. Further studies should help clarify the need to evaluate antibody levels and eventually revaccinate the increasing population of individuals who undergo weight reduction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Forty-two with hepatosplenic patients treated with praziquantel and followed up for 5 years. One half of the patients received a single 30 mg/kg dose and the other half, two doses of 25 mg/kg given 4 hrs apart. According to Hoffman and Kato-Katz stool exams, an 83.3% cure rate, was observed after twelve months. Stool egg counts in cases of incomplete cure were greatly reduced. Liver function, as assessed by serum levels of aspartate aminotransferase, alanine aminotransferase, gamma glutamyltransferase and alkaline phosphatase activities as well as albumin and gamma globulin showed marked improvement after one year. Hepatomegaly was reduced in 81.0% of patients and splenomegaly in 78.8%. Spleen regression was complete in 15.1% of the total, and in 18.5% of those with compensated hepatosplenic disease. As a result of these observations, the authors recomend early treatment with anti-schistosomal medication, either oxamniquine or praziquantel, to halt progression of disease and reduce splenomegaly.