25 resultados para Quasi-analytical algorithms
em Scielo Saúde Pública - SP
Resumo:
This paper describes the study population and the study design of the phase III field trial of the SPf66 vaccine in Brazil. Assessment of validity and precision principles necessary for the appropriate evaluation of the protective effect of the vaccine are discussed, as well as the results of the preliminary analyses of the gathered data. The analytical approach for the estimation of the protective effect of the vaccine is presented. This paper provides the conceptual framework for future publications.
Resumo:
The Fuenzalida-Palacios rabies vaccine has been used in South America for rabies post-exposure prophylaxis. To determine the frequency of adverse reactions associated with this vaccine compared to a control group a quasi-experimental study was carried out in Uberlândia, Brazil, from May 1997 to April 1998. Victims of bites or other injuries by dogs or other mammals and who received or not post-exposure prophylaxis with Fuenzalida-Palacios rabies vaccine were compared as to the occurrence of a list of signs and symptoms. Out of 2,440 victims of bites and other injuries from dogs and other mammals 2,114 participated in the study; 1,004 of them provided follow-up information within 10 to 15 days. Headache and pain at the injection sites were the most commonly found symptoms (125/1,000). No neuroparalytic event was detected. Patients who were given Fuenzalida-Palacios rabies vaccine and those who were not had similar incidences of symptoms (risk ratios close to 1). Regarding the occurrence of adverse reactions, Fuenzalida-Palacios rabies vaccine is a valid alternative for rabies post-exposure prophylaxis.
Resumo:
INTRODUCTION: Rotavirus is the main etiologic agent of acute infectious diarrhea in children worldwide. Considering that a rotavirus vaccine (G1P8, strain RIX4414) was added to the Brazilian vaccination schedule in 2006, we aimed to study its effectiveness and safety regarding intestinal intussusception. METHODS: A quasi-experimental trial was performed in which the primary outcome was the number of hospitalizations that were presumably due to acute infectious diarrhea per 100,000 children at risk (0-4 years old). The secondary outcomes included mortality due to acute infectious diarrhea and the intestinal intussusception rates in children in the same age range. We analyzed three scenarios: Health Division XIII of the State of São Paulo (DRS XIII) from 2002 to 2008, the State of São Paulo, and Brazil from 2002 to 2012. RESULTS: The averages of the hospitalization rates for 100,000 children in the pre- and post-vaccination periods were 1,413 and 959, respectively, for DRS XIII (RR=0.67), 312 and 249, respectively, for the State of São Paulo (RR=0.79), and 718 and 576, respectively, for Brazil (RR=0.8). The mortality rate per 100,000 children in the pre- and post-vaccination periods was 2.0 and 1.3, respectively, for DRS XIII (RR=0.66), 5.5 and 2.5, respectively, for the State of São Paulo (RR=0.47), and 15.0 and 8.0, respectively, for Brazil (RR=0.53). The average annual rates of intussusception for 100,000 children in DRS XIII were 28.0 and 22.0 (RR=0.77) in the pre- and post-vaccination periods, respectively. CONCLUSIONS: A monovalent rotavirus vaccine was demonstrated to be effective in preventing the hospitalizations and deaths of children that were presumably due to acute infectious diarrhea, without increasing the risk of intestinal intussusception.
Resumo:
Patulin is a mycotoxin produced by several fungal species of the genera Penicillium and Aspergillus, found on several fruit species and, remarkably, in apples and apple products. Patulin has a broad spectrum of toxicity, including carcinogenicity and teratogenicity in animals. Due to the stability of the molecule, considerable amounts of patulin still remain in apple products after processing. This paper reviews different analytical methods for patulin determination and methods to reduce levels of patulin in apple products as well.
Resumo:
Vancomycin is a glycopeptide antibiotic employed in the treatment of infections caused by certain methicillin-resistant staphylococci. It is indicated also for patients allergic to penicillin or when there is no response to penicillins or cephalosporins. The adequate vancomycin concentration levels in blood serum lies between 5 and 10 mg/L. Higher values are toxic, causing mainly nephrotoxicity and ototoxicity. Various analytical methods are described in the literature: spectrophotometric, immunologic, biologic and chromatographic methods. This paper reviews the main analytical methods for vancomycin determination in biological fluids and in pharmaceutical preparations.
Resumo:
Sweet, sour and bitter tasting fruits, vegetables and medicinal plants are an important component of human diet. The role of chromium and zinc in carbohydrate metabolism for control of diabetes is highlighted in selected commodities. Average levels of chromium and zinc in sweet taste were 0.69 ± 0.48 mg kg-1 and 4.81 ± 4.31 mg kg-1 respectively with correlation of 0.545, while in sour taste the values were 22.5 ± 22.0 mg kg-1 and 24.5 ± 11.8 mg kg-1 respectively with the correlation of 0.239 and in bitter taste, 0.61 ± 0.33 mg kg-1 and 4.70 ± 3.54 mg kg-1 respectively with correlation of 0.343. Overall, sour tasting commodities were found higher in levels of chromium and zinc and are recommended as food supplement for diabeties. None of these species contain metals above the toxic level.
Resumo:
Few articles deal with lead and strontium isotopic analysis of water samples. The aim of this study was to define the chemical procedures for Pb and Sr isotopic analyses of groundwater samples from an urban sedimentary aquifer. Thirty lead and fourteen strontium isotopic analyses were performed to test different analytical procedures. Pb and Sr isotopic ratios as well as Sr concentration did not vary using different chemical procedures. However, the Pb concentrations were very dependent on the different procedures. Therefore, the choice of the best analytical procedure was based on the Pb results, which indicated a higher reproducibility from samples that had been filtered and acidified before the evaporation, had their residues totally dissolved, and were purified by ion chromatography using the Biorad® column. Our results showed no changes in Pb ratios with the storage time.
Resumo:
This work describes a validation of an analytical procedure for the analysis of petroleum hydrocarbons in marine sediment samples. The proposed protocol is able to measure n-alkanes and polycyclic aromatic hydrocarbons (PAH) in samples at concentrations as low as 30 ng/g, with a precision better than 15% for most of analytes. The extraction efficiency of fortified sediments varied from 65.1 to 105.6% and 59.7 to 97.8%, for n-alkanes and PAH in the ranges: C16 - C32 and fluoranthene - benzo(a)pyrene, respectively. The analytical protocol was applied to determine petroleum hydrocarbons in sediments collected from a marine coastal zone.
Resumo:
Axis of quinary symmetry occur in molecular symmetry, as in the case of fullerenes, and in crystalline symmetry, in the quasicrystals. Minerals with pentagonal faces do not have this element of symmetry, as the pyrite (FeS2) which shows a ridge that is different from the other ones, in any face of the crystal. The purpose of this paper is to demonstrate conceptual differences between pyritohedron and regular pentagonal dodecahedron symmetries, discussing students' difficulties to identify them. Also is proposed a didactic experiment with spatial models of the above-mentioned forms and the demonstration of its symmetries in clinographic projections.
Resumo:
To assess topical delivery studies of glycoalkaloids, an analytical method by HPLC-UV was developed and validated for the determination of solasonine (SN) and solamargine (SM) in different skin layers, as well as in a topical formulation. The method was linear within the ranges 0.86 to 990.00 µg/mL for SN and 1.74 to 1000.00 µg/mL for SM (r = 0.9996). Moreover, the recoveries for both glycoalkaloids were higher than 88.94 and 93.23% from skin samples and topical formulation, respectively. The method developed is reliable and suitable for topical delivery skin studies and for determining the content of SN and SM in topical formulations.
Resumo:
We developed a simple, rapid, and solventless method for analyzing trihalomethanes in beer samples using headspace solid-phase microextraction. The effects of varying experimental parameters, such as extraction temperature and time, addition of sodium chloride, and agitation speed, on extraction yield were studied using a univariate experimental design. Limits of detection between 0.22 and 0.46 µg L- 1 and wide linear ranges were achieved for trihalomethanes. We measured the trihalomethane recoveries and precision (as the standard deviation of repeat measurements) and demonstrated the applicability of the proposed method by analyzing 32 beer samples.
Resumo:
In general, laboratory activities are costly in terms of time, space, and money. As such, the ability to provide realistically simulated laboratory data that enables students to practice data analysis techniques as a complementary activity would be expected to reduce these costs while opening up very interesting possibilities. In the present work, a novel methodology is presented for design of analytical chemistry instrumental analysis exercises that can be automatically personalized for each student and the results evaluated immediately. The proposed system provides each student with a different set of experimental data generated randomly while satisfying a set of constraints, rather than using data obtained from actual laboratory work. This allows the instructor to provide students with a set of practical problems to complement their regular laboratory work along with the corresponding feedback provided by the system's automatic evaluation process. To this end, the Goodle Grading Management System (GMS), an innovative web-based educational tool for automating the collection and assessment of practical exercises for engineering and scientific courses, was developed. The proposed methodology takes full advantage of the Goodle GMS fusion code architecture. The design of a particular exercise is provided ad hoc by the instructor and requires basic Matlab knowledge. The system has been employed with satisfactory results in several university courses. To demonstrate the automatic evaluation process, three exercises are presented in detail. The first exercise involves a linear regression analysis of data and the calculation of the quality parameters of an instrumental analysis method. The second and third exercises address two different comparison tests, a comparison test of the mean and a t-paired test.
Resumo:
The microencapsulation of palm oil may be a mechanism for protecting and promoting the controlled release of its bioactive compounds. To optimize the microencapsulation process, it is necessary to accurately quantify the palm oil present both external and internal to the microcapsules. In this study, we developed and validated a spectrophotometric method to determine the microencapsulation efficiency of palm oil by complex coacervation. We used gelatin and gum arabic (1:1) as wall material in a 5% concentration (w/v) and palm oil in the same concentration. The coacervates were obtained at pH 4.0 ± 0.01, decanted for 24 h, frozen (−40 ºC), and lyophilized for 72 h. Morphological analyzes were then performed. We standardized the extraction of the external palm oil through five successive washes with an organic solvent. We then explored the best method for rupturing the microcapsules. After successive extractions with hexane, we determined the amount of palm oil contained in the microcapsules using a spectrophotometer. The proposed method was shown to be of low cost, fast, and easy to implement. In addition, in the validation step, we confirmed the method to be safe and reliable, as it proved to be specific, accurate, precise, and robust.
Resumo:
The possibility of using thiocyanate to determine iron(II) and/or iron(III) in water-acetone mixture has been re-examined as part of a systematic and comparative study involving metallic complexes of pseudohalide ligands. Some parameters that affect the complete oxidation of the ferrous cations, their subsequent complexation and the system stability have been studied to optimize the experimental conditions. Our results show the viability and potentiality of this simply methodology as an alternative analytical procedure to determine iron cations with high sensitivity, precision and accuracy. Studies on the calibration, stability, precision, and effect of various different ions have been carried out by using absorbance values measured at 480 nm. The analytical curve for the total iron determination obeys Beer's law (r = 0.9993), showing a higher sensitivity (molar absorptivity of 2.10x10(4) L cm-1 mol-1) when compared with other traditional systems (ligands) or even with the "similar" azide ion [1.53x10(4) L cm-1 mol-1, for iron-III/azide complexes, in 70% (v/v) tetrahydrofuran/water, at 396 nm]. Under such optimized experimental conditions, it is possible to determine iron in the concentration range from 0.5 to 2 ppm (15-65% T for older equipments, quartz cells of 1.00 cm). Analytical applications have been tested for some different materials (iron ores), also including pharmaceutical products for anemia, and results were compared with atomic absorption determinations. Very good agreement was obtained with these two different techniques, showing the potential of the present experimental conditions for the total iron spectrophotometric determinations (errors < 5%). The possibility of iron speciation was made evident by using another specific and auxiliary method for iron(II) or (III).
Resumo:
A sensitive and alternative method for the spectrophotometric determination of chromium(III) based on the formation of chromium(III)/azide complexes was established by investigating a new band in the ultraviolet region. The best experimental conditions for the analytical determination of this metallic ion were: ligand and perchloric acid analytical concentration = 493 and 12.0 mmol L-1, respectively; aqueous medium; T = 25.0 ºC; contact time = 1 hour. The maximum molar absorptivity coefficient occurred at 287 nm (average 1.481 ± 0.008 ´ 10(4) L mol-1 cm-1), leading to the determination of metal ion concentrations one hundred times lower than the ones formerly determined in the visible region. The system obeys Beer's Law and is suitable for chromium determination in the 0.702-2.81 mg L-1 concentration range (15-65% T, 1.00 cm-width quartz cells). Analytical applications of the current method were tested with a nutritional supplement containing chromium. Results were compared with those obtained with atomic absorption spectrometry.