3 resultados para Poultney, Evan.

em Scielo Saúde Pública - SP


Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the aim to evaluate the circulating cathodic antigen (CCA) levels in relation to the different clinical phases of Schistosoma sp. infection a sandwich ELISA using monoclonal antibody 5H11 was performed. The sera of three groups of 25 Brazilian patients with acute, intestinal and hepatosplenic forms of S. mansoni infection were tested and compared to a non-infected control group. Patients and control groups were matched for age and sex and the number of eggs per gram of feces was equally distributed among the three patient groups. Sensitivity of 100%, 72%, 52% of the assay was observed for the intestinal, hepatosplenic and acute toxemic groups respectively. The specificity was 100%. Intestinal and hepatosplenic groups presented CCA levels significantly higher in comparison to those observed for acute patients (F-ratio = 2,524; p = 0.000 and F-ratio = 6,314; p = 0.015 respectively). There was no significant difference of CCA serum levels between hepatosplenic and intestinal groups (F-ratio = 1,026; p = 0.316).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For the past ten years, we have been exploring the relationship between schistosomiasis and human immunodeficiency virus (HIV-1) and how coinfection with both agents may affect the pathology and progression of each infection. To date, given the systems we have examined, the effects of HIV-1 on schistosomiasis have been more profound than the effects of schistosomiasis on HIV-1 progression. Additional key questions with important public health implications remain unanswered, but hopefully not unanswerable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: O objetivo deste trabalho foi obter a distribuição da dose absorvida no ar numa sala de mamografia durante a simulação de um exame mamográfico, visando a reavaliar a necessidade do uso de barreiras de proteção radiológica nessas salas e a exposição das pacientes. MATERIAIS E MÉTODOS: Os dados da dose absorvida no ar foram coletados mediante simulação de exame mamográfico de um simulador de mama de BR12, em um equipamento Senograph 600T-Senix HF. Para tal, 158 pastilhas de CaSO4 foram distribuídas em malhas retangulares em torno do bucky, em três alturas distintas. RESULTADOS: O valor mais elevado da dose absorvida no ar, registrado no ponto central da superfície do simulador, centralizado no feixe primário, foi de 8,33 mGy, enquanto o menor valor registrado, devido exclusivamente ao espalhamento, foi de 0,008 mGy. CONCLUSÃO: Estes resultados indicam que o uso de blindagem adicional nas salas de mamografia pode não ser necessário na incidência crânio-caudal, desde que as distâncias consideradas neste trabalho sejam observadas. No entanto, eles enfatizam a necessidade de proteção da paciente.