2 resultados para Polysulphone dosimeter

em Scielo Saúde Pública - SP


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective The authors have sought to study the calibration of a clinical PKA meter (Diamentor E2) and a calibrator for clinical meters (PDC) in the Laboratory of Ionizing Radiation Metrology at Instituto de Energia e Ambiente - Universidade de São Paulo. Materials and Methods Different qualities of both incident and transmitted beams were utilized in conditions similar to a clinical setting, analyzing the influence from the reference dosimeter, from the distance between meters, from the filtration and from the average beam energy. Calibrations were performed directly against a standard 30 cm3 cylindrical chamber or a parallel-plate monitor chamber, and indirectly against the PDC meter. Results The lowest energy dependence was observed for transmitted beams. The cross calibration between the Diamentor E2 and the PDC meters, and the PDC presented the greatest propagation of uncertainties. Conclusion The calibration coefficient of the PDC meter showed to be more stable with voltage, while the Diamentor E2 calibration coefficient was more variable. On the other hand, the PDC meter presented greater uncertainty in readings (5.0%) than with the use of the monitor chamber (3.5%) as a reference.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

West Indian cherry (Malpighia glabra L.) and pineapple (Ananas comosus (L.) Meer)juice clarification by cross-flow UF, using polysulphone hollow fiber and ceramic tubular membranes with, respectively, nominal molecular weight cut off values of 100kDaltons and average pore diameters of 0.01mm, were studied. The influence of enzymatic treatment using enzyme concentrations of 20, 100 and 300mg/L, a time of 90min and a temperature of 40ºC for depectinization was verified. The juices were then clarified in a laboratory scale filtration unit, with an effective filtration area of 0.12m² for the polysulphone hollow fiber membrane and of 0.005m² for the ceramic tubular membranes. The influence of enzymatic treatment on viscosity, turbidity and total pectin of the juice, before ultrafiltration, is reported. Membrane performance was evaluated in terms of flow rate and clarity of the permeate. The permeate flow rate of depectinized pineapple juice was higher (30 - 60%) for both membranes. Depectinized West Indian cherry juice presented a lower permeate flow rate for the polysulphone hollow fiber membrane. The increase in permeate flow rate, with the use of the 300mg/L and 100mg/L enzyme concentration was not significant, so it is economically advantageous to ultrafilter depectinized juice, treated with an enzyme concentration of 20mg/L.