46 resultados para POSITIONED FLAP
em Scielo Saúde Pública - SP
Resumo:
The autors present a case of bilateral vulvar defects after abrasion of malignant skin neoplasm, reconstructed with a gluteal-fold perforator flap, resulting in a successful outcome.
Resumo:
The authors detail the experimental development of a technique for the reconstruction of the ureter using a tubular shape, muscle flap of the abdominal wall. the preliminary results indicate the feasibility of this surgical technique.
Resumo:
Referimo-nos ao caso de um paciente masculino de setenta e cinco anos de idade, com um carcinoma espinocelular (SCC), que se originou na parte exterior da orelha direita há quatro anos. Sofreu uma remoção cirúrgica da parte lesionada combinada com dissecção modificada do pescoço e reconstrução com o uso de retalho peitoral maior. Além disso, teve radioterapia com 6000 rads na região temporal direita. Há dois meses o paciente mostrou urna recorrência expansiva no que diz respeito ao músculo temporal e ao osso, o osso litóide, os músculos masseter e os músculos pterigóideos, a parte direita da mandíbula, a glândula da parótida com o nervo facial, e o bulbo superior da veia jugular interna. Sofreu uma remoção cirúrgica da lesão afetada até as extremidades saudáveis e reconstrução estética e funcional com a utilização combinada de uma prótese de metal fixa do côndilo e da mandíbula direita e o uso de músculo-cutâneo trapezious flap. Apresentamos o relato de um caso sobre as opções de reconstrução que nós temos em nossos dias para proporcionar qualidade de vida a doentes que sofrem de cancro.
Resumo:
When the electrostatic spraying is used correctly, it provides advantages over conventional systems, however many factors can affect the system efficiency. Therefore, the objective of this study was to evaluate the charge/mass ratio (Q/M) at different spraying distances (0, 1, 2, 3, 4 and 5 m), and the liquid deposition efficiency on the target. Evaluating the Q/M ratio the Faraday cage method was used and to evaluate the liquid deposition efficiency the artificial targets were positioned longitudinally and transversely to the spray jet. It was found that the spraying distance affects the Q/M ratio, consequently, the liquid deposition efficiency. For the closest distance to the target the Q/M ratio was 4.11 mC kg-1, and at distances of 1, 2, 3, 4 and 5 m, the ratio decreased to 1.38, 0.64, 0.31, 0.17 and 0.005 mC kg-1, respectively. For the liquid deposition, the electrostatic system was affected by the target orientation and spraying distance. The target transversely to the jet of liquid did not improve the liquid deposition, but longitudinally increased the deposition up to 3 meters of distance.
Resumo:
Aedes aegypti is an important vector in Brazil being the main vector of the dengue-fever. This paper employs survival curves to describe the time in days from larvae to adult forms of Aedes aegypti raised, individually and collectively, and compares it during winter and spring when positioned inside and outside a laboratory. The study was conducted in São Vicente, a coastal city in Southeastern Brazil. The lowest water temperature in winter and in spring was 20 °C and the highest was 26 °C in spring. Higher and more stable temperatures were measured in the intra compared to the peri in both seasons. Consequently, larvae positioned in the intra resulted in the lowest median time to develop in the individual and collective experiment (nine and ten days, respectively). At least 25% of the larvae positioned in the intra in the individual experiment in the spring took only seven days to reach adulthood. Sex ratios and the median time development by sex did not show significant differences. These results indicate that efforts to control Aedes aegypti must be continuous and directed mainly to prevent the intra-domiciliary sites that can be infested in a week in order to reduce the human-vector contact.
Resumo:
IntroductionInfections caused by methicillin-resistant Staphylococcus aureus (MRSA) have become common in hospitals and the community environment, and this wide resistance has limited patient treatment. Clindamycin (CL) represents an important alternative therapy for infections caused by S. aureus. Antimicrobial susceptibility testing using standard methods may not detect inducible CL resistance. This study was performed to detect the phenotypes of resistance to macrolides-lincosamides-streptogramin B (MLSB) antibiotics, including CL, in clinical samples of S. aureusfrom patients at a tertiary hospital in Santa Maria, State of Rio Grande do Sul, Brazil.MethodsOne hundred and forty clinical isolates were submitted to the disk diffusion induction test (D-test) with an erythromycin (ER) disk positioned at a distance of 20mm from a CL disk. The results were interpreted according to the recommendations of the Clinical and Laboratory Standards Institute (CLSI).ResultsIn this study, 29 (20.7%) of the 140 S. aureus samples were resistant to methicillin (MRSA), and 111 (79.3%) were susceptible to methicillin (MSSA). The constitutive resistance phenotype (cMLSB) was observed in 20 (14.3%) MRSA samples and in 5 (3.6%) MSSA samples, whereas the inducible resistance phenotype (iMLSB) was observed in 3 (2.1%) MRSA samples and in 8 (5.8%) MSSA samples.ConclusionsThe D-test is essential for detecting the iMLSBphenotype because the early identification of this phenotype allows clinicians to choose an appropriate treatment for patients. Furthermore, this test is simple, easy to perform and inexpensive.
Resumo:
The authors analysed a series of 22 patients undergoing surgical correction of congenital hand syndactyly by the rectangular flap technique. Using our evaluation method, we found that good functional and aesthetic results were obtained in 77.3% of the patients, with a complication rate of 13.6%. We concluded that the rectangular flap technique has a simple design, is easily reproducible by in-training staff, has good results, and can be applied on the majority of the syndactyly cases.
Resumo:
The rejection of allotransplantation of epigastric microsurgical flaps and the effect of immunosuppression have been studied in 58 rats. Three sets of experiments were planned: (1) Wistar Furth isogenic donors and receptors (control set); (2) Brown Norway donors and Wistar Furth receptors (rejection set); and (3) Brown Norway donors and Wistar Furth immunosuppressed receptors (cyclosporin A set). Cyclosporin A (10 mg/kg/d) treated rats had a transplantation survival rate of up to 30 days: 83.3% among isogenic animals and 60% among allogeneic. There was 100% rejection by the 9th day after the transplantation in allogeneic non-immunosuppressed rats. Biopsies embedded with historesin were taken from the flap and normal contralateral skin (used as control) on the 3rd, 7th, 15th, and 30th days after the surgery. A quantitative study of infiltrating lymphocytes in the flaps, with and without cyclosporin A, was done by evaluating the local inflammatory infiltrate. A significant increase in the number of lymphocytes among the rejection and immunosuppressed groups was seen, as compared to the isogenic set. Local lymphocytosis in allogeneic non-immunosuppressed transplantations reached its highest level on the 3rd day after surgery, before gross findings of rejection, which could only be seen by naked eye on the 5th or 6th day. Therefore, we conclude that cyclosporin A is effective in preserving allogenic transplantation in rats. Biopsies of transplanted areas may contribute to earlier diagnosis of the need for immunosuppressive therapy.
Resumo:
Treatment of arterial traumatic intimal lesions is controversial due to its unknown natural history. Current therapeutical options include arterial reconstruction and clinical observation. The idea of using stents to correct intimal flaps is based on their use to correct dissections, flaps, and arterial irregularities after angioplasty. We report the successful treatment of a traumatic intimal flap of the superficial femoral artery, caused by gunshot trauma, with a Palmaz stent in the acute period. One year after the operation, a duplex scan revealed normal flow in the artery and complete exclusion of the intimal flap; distal pulses were palpable, and the patient was completely asymptomatic.
Resumo:
INTRODUCTION: Tissue expanders have been of great value in plastic surgery. Tissue expansion was developed for a specific indication; however, within a very short time, the concept of tissue expansion found wide applicability. From 1990 to 1999, 315 expanders in 164 patients were utilized. A retrospective analysis of complications and prognostic factors for complications were done. METHODS: The indications for tissue expansion were burns (50%), trauma (32%), and sequelae of previous surgery (8.8%). The expanders were inserted most frequently in the scalp, trunk and neck. RESULTS: There were 22.2% of complications and the most common were expander exposure (50%), infection (24%) and bad function of the expander (12.8%). The present study revealed an increased rate of minor complications in the group of 0 to 10 years of age and an increased rate of major complications for face and neck expansions compared to trunk expansion. There were no increased complication rates for the other age and anatomic site groups, previous expansion, concomitant expansion and type of expander used. CONCLUSIONS: The outcomes from tissue expansion procedures done in our hospital are similar to those reported in the literature. Tissue expansion is a good and safe technique.
Resumo:
Treatment of wounds using conventional methods is frequently limited by inadequate local wound conditions, or by a poor systemic clinical situation. Vacuum system may promote faster granulation tissue formation, remove excessive exudate, increase blood flow in the wound, and attract the borders of the wound to the center, reducing its dimension. We present 3 cases of patients with difficult wounds, due to bad local conditions, or poor clinical situation, in whom we used a vacuum system to prepare the wound for the surgical closure. One patient had a pressure ulcer, another had a diabetic foot ulcer, and the third one had an open foot stump. In the 3 cases a significant improvement of the wound conditions was achieved after 7 to 8 days, allowing successful surgical treatment with flap or skin grafts.
Resumo:
The patient is a 54-year-old asymptomatic male with a tumor in the right atrium that was diagnosed on transesophageal echocardiography and confirmed as a lipoma of the right atrium on computerized tomography. The patient underwent surgical repair with extracorporeal circulation. The tumor was resected, and its base of implantation in the atrium was repaired with a flap of bovine pericardium. The diagnosis of lipoma was confirmed on histopathological examination. Locating of the tumor with the aid of transesophageal echocardiography was very useful in the strategy of cannulation of the venae cava for installation of the circuit of extracorporeal circulation. The patient had a good postoperative evolution.
Resumo:
Congenital supravalvular mitral stenosis is a rare malformation characterized by the presence of a shelf-like fibrous membrane, with 1 or 2 small orifices, covering and obstructing the mitral valve. The membrane is positioned closely to the mitral valve (and sometimes it is attached to it); therefore, a preoperative diagnosis is inevitably difficult, even with the use of biplane echocardiography. Two patients with supravalvular mitral stenosis aged 3 years and 3 months are described. In 1 patient, a preoperative diagnosis was made, and both successfully underwent correction.
Resumo:
É relatado o caso de um paciente do sexo masculino com idade de 71 anos, dando entrada no pronto-atendimento com palidez cutaneomucosa, acompanhada de hipertensão arterial sistêmica e dor torácica. Na investigação diagnóstica não foi evidenciada alteração compatível com isquemia miocárdica aguda. A radiografia de tórax evidenciava alargamento importante do mediastino. Ao ecocardiograma, a aorta ascendente media 47 mm, no nível do tronco pulmonar. Um dia após o eco, o paciente foi submetido a exame de ressonância magnética (RNM), quando se evidenciou aorta ascendente de 62 mm, sem evidenciar fluxo em falsa luz ou "flap" intimal, mas mostrando hematoma intramural da aorta ascendente, estendendo-se da raiz da aorta até um terço proximal do arco aórtico. Procedeu-se a correção cirúrgica, sendo realizada substituição da aorta ascendente e parte do arco aórtico (hemiarco), com preservação da valva aórtica pela suspensão das comissuras. Paciente evolui bem sem intercorrência, recebendo alta no nono dia de pós-operatório. Enfatizamos nesse relato de caso a semelhança do quadro clínico do hematoma intramural da aorta com o quadro de dissecção da aorta, a importância de se estabelecer diagnóstico correto e o melhor tratamento.
Resumo:
In order to evaluate the efficiency of different mammalian survey methods, we compared traditional sampling techniques (use of camera-traps on roads and artificial trails, track censuses, and direct field visualization) with an alternative sampling design (camera-traps positioned in natural areas such as natural trails and shelters). We conducted the study in a deciduous Atlantic-Forest park in southern Brazil, and additionally compared our results with a previous intensive study carried out in the same area. Our considerably smaller sampling effort (example: 336 trap.day for our camera-traps versus 2,154 trap.day for the earlier study) registered the presence of 85% of the local known species, with camera-traps being 68% efficient. Moreover, shelter camera-traps revealed a different species composition regarding most of other sampling methods. This sampling strategy involving natural forest sites was therefore able to effectively optimize the chances of evaluating species composition in a shorter period, especially with respect to lower-density and cryptic species, as well as to detect species that avoid open, disturbed sites such as roads and man-made forest trails.