3 resultados para POLYGON

em Scielo Saúde Pública - SP


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Forest cover of the Maringá municipality, located in northern Parana State, was mapped in this study. Mapping was carried out by using high-resolution HRC sensor imagery and medium resolution CCD sensor imagery from the CBERS satellite. Images were georeferenced and forest vegetation patches (TOFs - trees outside forests) were classified using two methods of digital classification: reflectance-based or the digital number of each pixel, and object-oriented. The areas of each polygon were calculated, which allowed each polygon to be segregated into size classes. Thematic maps were built from the resulting polygon size classes and summary statistics generated from each size class for each area. It was found that most forest fragments in Maringá were smaller than 500 m². There was also a difference of 58.44% in the amount of vegetation between the high-resolution imagery and medium resolution imagery due to the distinct spatial resolution of the sensors. It was concluded that high-resolution geotechnology is essential to provide reliable information on urban greens and forest cover under highly human-perturbed landscapes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To analyze if the distribution of specialized care services for HIV/AIDS is associated with AIDS rates. METHODS Ecological study, for which the distribution of 10 specialized care services in the Ceara state, Northeastern Brazil, was obtained, and the mean rates of the disease were estimated per mesoregion. We evaluated 7,896 individuals who had been diagnosed with AIDS, were aged 13 years or older, lived in Ceara, and had been informed of their condition between 2001 and 2011. Maps were constructed to verify the relationship between the distribution of AIDS cases and institutionalized support networks in the 2001-2006 and 2007-2011 periods. BoxMap and LisaMap were used for data analysis. The Voronoi diagram was applied for the distribution of the studied services. RESULTS Specialized care services concentrated in AIDS clusters in the metropolitan area. The Noroeste Cearense and west of the Sertoes Cearenses had high AIDS rates, but a low number of specialized care services over time. Two of these services were implemented where clusters of the disease exist in the second period. The application of the Voronoi diagram showed that the specialized care services located outside the metropolitan area covered a large territory. We identified one polygon that had no services. CONCLUSIONS The scenario of AIDS cases spread away from major urban areas demands the creation of social support services in areas other than the capital and the metropolitan area of the state; this can reduce access barriers to these institutions. It is necessary to create specialized care services for HIV/AIDS in the Noroeste Cearense and north of Jaguaribe.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, the morphological characteristics of cocoa beverage powder granules under minimal, average, and maximal process conditions of a steam agglomerator were studied. a stereoscopic microscope coupled to a digital camera was used for the morphological analysis. The images were analyzed to obtain shape and size descriptors. aiming to evaluate the descriptors, 150 particles were analyzed. The results showed that there was no difference between the shape descriptors - compacity, circularity, roughness, and aspect ratio - in the operating conditions evaluated. It was observed that the cocoa beverage powder granules are elongated in shape. The size descriptors, area, perimeter, perimeter of convex bounding polygon, minimal and maximal Feret diameter, were different in the process conditions for the granules of size above 600 μm. as for the minimal process conditions, especially due to low solid feed rates, there is an increase in the size descriptor values. In addition, under the minimum process conditions, in which there is low solid feed rate (400g/min) for a steam pressure of 1.0 bar, it was obtained a good granular condition with retention of 81.1% of granules on sieves with aperture size between 300 and 1190 μm.