27 resultados para POLY(DIMETHYLSILOXANE) MICROFLUIDIC DEVICES
em Scielo Saúde Pública - SP
Resumo:
The amazing world of micro total analysis systems has provided a true revolution in analytical chemistry in recent years. The application of the microfluidic devices for chemical and biochemical processing has attracted considerable interest due to its advantages such as reduced sample and reagent consumption, processing time, energy, waste, cost, and portability. The aim of the present report is to disseminate the state of the art related to the miniaturization science in Analytical Chemistry. Historical progress, microfabrication technologies, required instrumentation and applications of the mTAS are presented in the current article, with special attention to the Brazilian contributions.
Resumo:
C18 chemically bonded sorbents have been the main materials used in solid phase extraction (SPE). However, due their high hydrophobicity some hydrophobic solutes are strongly retained leading to the consumption of larger quantities of organic solvent for efficient recoveries. This work presents a sorbent with lower hydrophobicity but similar selectivity to the C18 sorbent, prepared by thermal immobilization of poly(dimethylsiloxane-co-alkylmethylsiloxane) (PDAS) on silica. PDAS has organic chains with methyl groups alternating with octadecyl or hexadecyl groups in its monomeric unities. For the Si(PDAS) sorbent presented, the polymeric layer was physically adsorbed on the silica surface with 12% carbon load. Although the coating of silica with the polymeric layer was incomplete, the PDAS provided better protection for the silica surface groups, promoting mostly hydrophobic interactions between analytes and the sorbent. Sorption isotherm studies revealed that the retention of hydrophobic solutes on Si(PDAS) was less intense than on conventional sorbents, confirming the lower hydrophobicity of the lab-made sorbent. Additional advantages of Si(PDAS) include simplicity and low cost of preparation, making this material a potential sorbent for the analysis of highly hydrophobic solutes.
Resumo:
Successful vaccine application means maximum protection with minimal number of administrations. A rational development of vaccines involves studies of the nature of the antigen as well as of the adjuvant to be used to improve the immune responses. This has provided the impetus for studies to design the degradable devices and for different approaches to antigen delivery by different routes of administration. The development of controlled release systems based on polymeric devices that permit a sustained or pulsed release of encapsulated antigens has attracted much interest. Polymeric delivery systems consist of polymers that release their content continuously in a controlled manner over a period of time. The development of a biocompatible delivery system for parenteral administration offers several advantages in terms of immunoadjuvanticity over other compounds. It was found that, in contrast to other carriers, microspheres are more stable, thus permitting administration by the oral or parenteral route. In the present study, we describe the main characteristics and potentialities of this new immunoadjuvant for oral and parenteral administration.
Resumo:
OBJECTIVE To analyze whether sociodemographic, occupational, and health-related data are associated with the use of hearing protection devices at work, according to gender. METHODS A cross-sectional study was conducted in 2006, using a random sample of 2,429 workers, aged between 18 and 65 years old, from residential sub-areas in Salvador, BA, Northeastern Brazil. Questionnaires were used to obtain sociodemographic, occupational, and health-related data. Workers who reported that they worked in places where they needed to shout in order to be heard were considered to be exposed to noise. Exposed workers were asked whether they used hearing protection devices, and if so, how frequently. Analyses were conducted according to gender, with estimates made about prevalence of the use of hearing protection devices, prevalence ratios, and their respective 95% confidence intervals. RESULTS Twelve percent (12.3%) of study subjects reported that they were exposed to noise while working. Prevalence of the use of hearing protection devices was 59.3% for men and 21.4% for women. Men from higher socioeconomic levels (PR = 1.47; 95%CI 1.14;1.90) and who had previous audiometric tests (PR = 1.47; 95%CI 1.15;1.88) were more likely to use hearing protection devices. For women, greater perceived safety was associated with the use of protection devices (PR = 2.92; 95%CI 1.34;6.34). This perception was specifically related to the presence of supervisors committed to safety (PR = 2.09; 95%CI 1.04;4.21), the existence of clear rules to prevent workplace injuries (PR = 2.81; 95%CI 1.41;5.59), and whether they were informed about workplace safety (PR = 2.42; 95%CI 1.23;4.76). CONCLUSIONS There is a gender bias regarding the use of hearing protection devices that is less favorable to women. The use of such devices among women is positively influenced by their perception of a safe workplace, suggesting that gender should be considered as a factor in hearing conservation programs.
Resumo:
PURPOSE: Infection is the leading complication of long-term central venous catheters, and its incidence may vary according to catheter type. The objective of this study was to compare the frequency and probability of infection between two types of long-term intravenous devices. METHODS: Retrospective study in 96 onco-hematology patients with partially implanted catheters (n = 55) or completely implanted ones (n = 42). Demographic data and catheter care were similar in both groups. Infection incidence and infection-free survival were used for the comparison of the two devices. RESULTS: In a median follow-up time of 210 days, the catheter-related infection incidence was 0.2102/100 catheter-days for the partially implanted devices and 0.0045/100 catheter-days for the completely implanted devices; the infection incidence rate was 46.7 (CI 95% = 6.2 to 348.8). The 1-year first infection-free survival ratio was 45% versus 97%, and the 1-year removal due to infection-free survival ratio was 42% versus 97% for partially and totally implanted catheters, respectively (P <.001 for both comparisons). CONCLUSION: In the present study, the infection risk was lower in completely implanted devices than in partially implanted ones.
Resumo:
OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.
Resumo:
OBJECTIVE: To study the mechanism by which poly-L-arginine mediates endothelium-dependent relaxation. METHODS: Vascular segments with and without endothelium were suspended in organ chambers filled with control solution maintained at 37ºC and bubbled with 95% O2 / 5% CO2. Used drugs: indomethacin, acetycholine, EGTA, glybenclamide, ouabain, poly-L-arginine, methylene blue, N G-nitro-L-arginine, and verapamil and N G-monomethyl-L-arginine. Prostaglandin F2á and potassium chloride were used to contract the vascular rings. RESULTS: Poly-L-arginine (10-11 to 10-7 M) induced concentration-dependent relaxation in coronary artery segments with endothelium. The relaxation to poly-L-arginine was attenuated by ouabain, but was unaffected by glybenclamide. L-NOARG and oxyhemoglobin caused attenuation, but did not abolish this relaxation. Also, the relaxations was unaffected by methylene blue, verapamil, or the presence of a calcium-free bathing medium. The endothelium-dependent to poly-L-arginine relaxation was abolished only in vessels contracted with potassium chloride (40 mM) in the presence of L-NOARG and indomethacin. CONCLUSION: These experiments indicate that poly-L-arginine induces relaxation independent of nitric oxide.
Resumo:
The great expansion in the number of genome sequencing projects has revealed the importance of computational methods to speed up the characterization of unknown genes. These studies have been improved by the use of three dimensional information from the predicted proteins generated by molecular modeling techniques. In this work, we disclose the structure-function relationship of a gene product from Leishmania amazonensis by applying molecular modeling and bioinformatics techniques. The analyzed sequence encodes a 159 aminoacids polypeptide (estimated 18 kDa) and was denoted LaPABP for its high homology with poly-A binding proteins from trypanosomatids. The domain structure, clustering analysis and a three dimensional model of LaPABP, basically obtained by homology modeling on the structure of the human poly-A binding protein, are described. Based on the analysis of the electrostatic potential mapped on the model's surface and conservation of intramolecular contacts responsible for folding stabilization we hypothesize that this protein may have less avidity to RNA than it's L. major counterpart but still account for a significant functional activity in the parasite. The model obtained will help in the design of mutagenesis experiments aimed to elucidate the mechanism of gene expression in trypanosomatids and serve as a starting point for its exploration as a potential source of targets for a rational chemotherapy.
Resumo:
Recent work has demonstrated that hyperglycemia-induced overproduction of superoxide by the mitochondrial electron-transport chain triggers several pathways of injury [(protein kinase C (PKC), hexosamine and polyol pathway fluxes, advanced glycation end product formation (AGE)] involved in the pathogenesis of diabetic complications by inhibiting glyceraldehyde-3-phosphate dehydrogenase (GAPDH) activity. Increased oxidative and nitrosative stress activates the nuclear enzyme, poly(ADP-ribose) polymerase-1 (PARP). PARP activation, on one hand, depletes its substrate, NAD+, slowing the rate of glycolysis, electron transport and ATP formation. On the other hand, PARP activation results in inhibition of GAPDH by poly-ADP-ribosylation. These processes result in acute endothelial dysfunction in diabetic blood vessels, which importantly contributes to the development of various diabetic complications. Accordingly, hyperglycemia-induced activation of PKC and AGE formation are prevented by inhibition of PARP activity. Furthermore, inhibition of PARP protects against diabetic cardiovascular dysfunction in rodent models of cardiomyopathy, nephropathy, neuropathy, and retinopathy. PARP activation is also present in microvasculature of human diabetic subjects. The present review focuses on the role of PARP in diabetic complications and emphasizes the therapeutic potential of PARP inhibition in the prevention or reversal of diabetic complications.
Resumo:
We have been able to label the excretory system of cercariae and all forms of schistosomula, immature and adult worms with the highly fluorescent dye resorufin. We have shown that the accumulation of the resorufin into the excretory tubules and collecting ducts of the male adult worm depends on the presence of extracellular calcium and phosphate ions. In the adult male worms, praziquantel (PZQ) prevents this accumulation in RPMI medium and disperses resorufin from tubules which have been prelabelled. Female worms and all other developmental stages are much less affected either by the presence of calcium and phosphate ions, or the disruption caused by PZQ. The male can inhibit the excretory system in paired female. Fluorescent PZQ localises in the posterior gut (intestine) region of the male adult worm, but not in the excretory system, except for the anionic carboxy fluorescein derivative of PZQ, which may be excreted by this route. All stages of the parasite can recover from damage by PZQ treatment in vitro. The excretory system is highly sensitive to damage to the surface membrane and may be involved in vesicle movement and damage repair processes. In vivo the adult parasite does not recover from PZQ treatment, but what is inhibiting recovery is unknown, but likely to be related to immune effector molecules.
Resumo:
AbstractOBJECTIVETo analyze the care implemented by the nursing team to promote the safety of adult patients and prevention of skin and mucosal lesions associated with the presence of lower airways invasive devices.METHODStudy with qualitative and quantitative approach, descriptive and exploratory type, whose investigative scenarios were adult inpatient units of a hospital in the West Frontier of Rio Grande do Sul. The study subjects consisted of nurses, nursing technicians and nursing assistants.RESULTSA total of 118 professionals were interviewed. We highlight the observed specific care with endotracheal tube and tracheostomy, management and assessment of the cuff and the criteria used to secretion aspiration.CONCLUSIONThere is a superficial nursing work in the patient direct care and a differentiation in relation to the perception of nurse technicians, especially those working in the intensive care unit, who presented major property and view of the patient's clinical status.
Resumo:
A study is presented of the formation and optical properties of polymeric heterostructures from poly(p-phenylene vinylene) (PPV) and poly(o-methoxyaniline) (POMA) produced via the self-assembly technique. POMA layers were obtained in a non self-limiting process from its emeraldine salt, semiconducting form in HCl solution. Thermal conversion of PPV was performed at low temperatures with the substitution of the counter-ion Cl in the PPV precursor by a long sulfonic chain, the dodecylbenzenesulfonate (DBS) ion. The optical properties of PPV films converted in this way are not affected by POMA, which can be used as transparent electrode of PPV luminescent devices.
Resumo:
An aliphatic-aromatic copolyester of poly(ethylene terephthalate), PET, and poly(ethylene adipate), PEA, PET-co-PEA, was synthesized by the high temperature melt reaction of post-consumer PET and PEA. As observed by NMR spectroscopy, the reaction yielded random copolyesters in a few minutes through ester-interchange reactions, even without added catalyst. The copolyesters obtained in the presence of a catalyst presented higher intrinsic viscosity than that obtained without the addition of catalyst, due to simultaneous polycondensation and ester-interchange reactions. The structure of the aliphatic-aromatic copolyesters obtained in different PET/PEA ratio is random as observed by NMR analysis.
Resumo:
Here we present an overview of electroluminescent devices that use conjugated polymers as the active media. The principal components of the devices are described and we show some examples of conjugated polymers and copolymers usually employed in polymeric light emitting devices (PLED). Some aspects of the photo and electroluminescence properties as well as of the energy transfer processes are discussed. As an example, we present some of the photophysical properties of poly(fluorene)s, a class of conjugated polymers with blue emission.
Resumo:
Water-in-crude oil emulsions are formed during petroleum production and asphaltenes play an important role in their stabilization. Demulsifiers are added to destabilize such emulsions,however the demulsification mechanism is not completely known. In this paper, the performances of commercial poly(ethylene oxide-b-propylene oxide) demulsifiers were studied using synthetic water-in-oil emulsions and model-systems (asphaltenes in organic solvent). No change in the asphaltene aggregate size induced by the demulsifier was observed. The demulsification performance decreased as the asphaltene aggregate size increased, so it can be suggested that the demulsification mechanism is correlated to the voids between the aggregates adsorbed on the water droplets surface.