22 resultados para PERMEATION
em Scielo Saúde Pública - SP
Resumo:
This work discusses sample preparation processes for gas chromatography (GC) based on the technique of extraction through membrane permeation (MPE). The MPE technique may be easily coupled to GC via a relatively simple device, which is a module that holds the membrane and is directly connected to the GC column. The possibility of operational errors due to sample handling is substantially reduced in an MPE-GC system because the sample preparation and the chemical analysis are accomplished as a one-step process. The MPE technique is of relatively wide application as it can be used for aqueous samples, solid samples and gaseous samples. Depending on the type of sample the extraction is performed with the membrane in direct contact with the sample or in contact with its headspace. The MPE-GC technique is very useful in trace analysis, due to the time-dependent enrichment of the analyte. A typical application of MPE-GC is the analysis of VOCs present in water that may be accomplished with detection limits at the low ppb (mugL-1) level.
Resumo:
A sequential system for fractionation by ultrafiltration (SSFU) equipped with advanced membranes filters (molecular size cut-off: 5, 10, 30, 50 and 100 kDalton) of the polyethersulfone type was developed for analytical fractionation of humic substances (HS) extracted from aquatic systems or soils. The device consists of five membrane filters (Sartocon® Micro) operated by a multi-channel peristaltic pump, enabling an easy handling, working in a closed system and with simple collection of the six obtained fractions (F1>100; F2: 100-50; F3: 50-30; F4:30-10; F5: 10-5 and F6 <5 kDalton). Then, the HS sample (250 mL solution 1.0 mg/mL, pH 5.0 to 6.0) to be fractionated is pumped by pump through the series of membrane filters with a tangential flow of 85 mL/min, initial pressure 0.2 to 0.3 bar and permeation flux through the membranes of 0.8 to 1.4 mL/min. The overall time for fractionation and cleaning of the device is about 10 h and 25 mL of each fraction is obtained.
Resumo:
In this work, samples of chitosan obtained in different conditions were characterized by molecular weight distribution, using Gel Permeation Chromatography (GPC), in two different solvents. It was observed that the increase in the number of deacetylation steps promotes a increase in the degree of deacetylation followed by a decrease in the average of molecular weight and polydispersion. The GPC curves obtained for chitosan samples in the two solvents used (CH3COOH 0.30 mol/dm³ - CH3CONa 0.20 mol/dm³ and CH3COOH 0.10 mol/dm³ - NaCl 0.20 mol/dm³) showed small difference in elution volume, but significant changes in the average molecular weight (Mn and Mw) and polydispersion that, in agree with the values of Huggins constant, present evidences of chitosan aggregates formation in the second solvent.
Resumo:
The passive sampling technique has been widely used for many years in the measurement of personal exposure to pollutantes in the workplace. In recent years the technique has been used too for measurements in ambient air. In the specific case of SO2 a variety of passive samplers have been described in the literature. The great number are diffusive samplers and some few are permeation samplers. They are basically of two types: badge and tube-type. However there are more than 10 variations in relation to the sampler dimensions, diffusion barriers and pollutant sorption medium. The technique trend to be very used in the near future with samplers able to reach very low detection limits, proposing a viable option for monitoring specific species at urban, regional and global scales.
Resumo:
This paper describes the analytical methods for determination of total chlorogenic acid (CGA) and their individual isomers. Spectrofotometric methods are adequate for total CGA analysis in green coffee but they can provide inflated results for coffee products. High pressure liquid chromatography (HPLC) with gel permeation column and ultraviolet (UV) monitoring is adequate for the simultaneous analysis of total CGA, alkaloids and sugars in coffee products. HPLC-UV-reversed phase is a simple, rapid and precise method for the determination of the individual isomers of CGA. Gas chromatography (GC) also is applied to the analysis of the individual isomers but phenolic acids need to be derivatized before analysis. Both HPLC- and GC-mass spectrometry provide an unequivocal identification of the individual isomers. The capillary electrophoresis method is simple, rapid and adequate to the simultaneous analysis of polyphenols and xanthines. Advantages and limitations of each method are discussed throughout the text.
Use of thin films obtained by plasma polymerization for grain protection and germination enhancement
Resumo:
In this work, preliminary results of the use of hydrophobic thin films obtained by plasma deposition to protect grains and seeds are presented: grains coated by the films did not present biological degradation when stored in a saturated water vapor environment, but had their germination accelerated in the presence of water. A model that explains the difference of behavior of the films when exposed to water in vapor form or in liquid form, based on the formation of microchannels within the film that lead to water uptake in seeds, is presented. The model was successfully tested using quartz crystal measurements, which showed that the microchannels within the films can favor the adsorption and permeation of water when the films are immersed in water.
Resumo:
Gravimetric and Bailey-Andrew methods are tedious and provide inflated results. Spectrofotometry is adequate for caffeine analysis but is lengthy. Gas chromatography also is applied to the caffeine analysis but derivatization is needed. High performance liquid chromatography with ultraviolet detection (HPLC-UV) and reversed phase is simple and rapid for xanthine multianalysis. In HPLC-UV-gel permeation, organic solvents are not used. HPLC-mass spectrometry provides an unequivocal structural identification of xanthines. Capillary electrophoresis is fast and the solvent consumption is smaller than in HPLC. Chemometric methods offer an effective means for chemical data handling in multivariate analysis. Infrared spectroscopy alone or associated with chemometries could predict the caffeine content in a very accurate form. Electroanalytical methods are considered of low cost and easy application in caffeine analysis.
Resumo:
The aim of this work is the production and characterization of plasma polymerized acetaldehyde thin films. These films show highly polar species, are hydrophilic, organophilic and easily adsorb organic reactants with CO radicals but only allow permeation of reactants with OH radicals. The good step coverage of films deposited on aluminum trenches is useful for sensor development. Films deposited on hydrophobic substrates may result in a discontinued layer, which allows the use of preconcentration in sample pretreatment. Deposition on microchannels showed the possibility of chromatographic columns and/or retention system production to selectively detect or remove organic compounds from gas flows.
Resumo:
The goal of this study was to produce and characterize a new microemulsion gel-like carrier system (MEG) by using the pseudo-ternary phase-diagram concept. The diclofenac diethylamine (DDA) was incorporated in the MEG and its in vitro release and permeation profiles were performed using Franz-type diffusion cells. The results revealed that the commercial DDA emulgel provided significantly higher Kp of DDA (2.2-fold) as compared to the MEG. Similar data were obtained in the permeation studies in which DDA Kp 4.7-fold higher. Therefore, MEG presents higher potential as a topical delivery system for DDA when compared to the commercial DDA emulgel.
Resumo:
Alteration in hydrophilicity feature of chitosan films by hexamethyldisilazane (HMDS) cold-plasma treatment is evaluated. All treated films were colorless and transparent with no apparent textural changes. The effect on surfaces was characterized through contact angle measurements, degree of swelling and water vapor permeation. A significant reduction in all of the hydrophilicity parameters was observed. It is assumed that the HMDS treatment forms nonpolar silicone type structures. The goal is to investigate the formation of a stable hydrophobic barrier in order to increase the chitosan films usefulness in packaging applications.
Resumo:
The exopolysaccharides with characteristics of gel produced by Rhizobium tropici (EPS RT) and Mesorhizobium sp (EPS MR) are acidic heteropolysaccharide composed mainly of glucose and galactose in a molar ratio of 4:1 and 5:1 respectively, with traces of mannose (~ 1%). Chemical analysis showed the presence of uronic acid, pyruvate and acetyl-substituents in the structures of both polymers. Experiments of gel permeation chromatography and polyacrylamide gel electrophoresis showed that EPS RT and EPS MR are homogeneous molecules with low grade of polydispersity. The EPS were characterized using spectroscopic techniques of FT-IR, ¹H and 13C-NMR.
Resumo:
This paper presents a review of different chemical compositions that are used in the production of mixed ionic-electronic conducting membranes with the perovskite structure. In these dense membranes, oxygen from the air is permeated through ionic and electronic processes, and high oxygen permeation fluxes are observed at high temperatures (800-900 ºC). Various membranes were compared for their performance and properties after being synthesized by different methods.
Resumo:
Bionanocomposites derived from poly(L-Lactide) (PLLA) were reinforced with chemically modified cellulose nanocrystals (m-CNCs). The effects of these modified cellulose nanoparticles on the mechanical and hydrolytic degradation behavior of polylactide were studied. The m-CNCs were prepared by a method in which hydrolysis of cellulose chains is performed simultaneously with the esterification of hydroxyl groups to produce modified nanocrystals with ester groups. FTIR, elemental analysis, TEM, XRD and contact angle measurements were used to confirm and characterize the chemical modifications of the m-CNCs. These bionanocomposites gave considerably better mechanical properties than neat PLLA based on an approximately 100% increase in tensile strength. Due to the hydrophobic properties of the esterified nanocrystals incorporated into a polymer matrix, it was also demonstrated that a small amount of m-CNCs could lead to a remarkable decrease in the hydrolytic degradation rate of the biopolymer. In addition, the m-CNCs considerably delay the degradation of the nanocomposite by providing a physical barrier that prevents the permeation of water, which thus hinders the overall absorption of water into the matrix. The results obtained in this study show the nanocrystals can be used to reinforce polylactides and fine-tune their degradation rates in moist or physiological environments.
Resumo:
Appendiceal tumors are rare and usually presented as acute appendicitis. They are incidentally discovered at an emergency surgery, in which case the decision-making is very difficult. The purpose of this report is discuss to the most appropriate management for appendiceal tumors. A retrospective analysis of one case treated at HU-UEL was undertaken and the literature was reviewed. The conclusion is that frozen section should be done whenever the appendiceal findings are atypical. For appendiceal carcinoids greater than 2 cm and adenocarcinomas, a right hemicolectomy is recommended. Appendectomy is apropriate for patients whose carcinoid tumors are 1 cm in diameter or less and for carcinoid tumors between 1 cm and 2 cm without extensive lymphatic permeation and mesenteric invasion. Every case should be searched for synchronous tumors.