5 resultados para NONLINEAR-OPTICAL RESPONSES
em Scielo Saúde Pública - SP
Resumo:
We describe the preparation and some optical properties of high refractive index TeO2-PbO-TiO2 glass system. Highly homogeneous glasses were obtained by agitating the mixture during the melting process in an alumina crucible. The characterization was done by X-ray diffraction, Raman scattering, light absorption and linear refractive index measurements. The results show a change in the glass structure as the PbO content increases: the TeO4 trigonal bipyramids characteristics of TeO2 glasses transform into TeO3 trigonal pyramids. However, the measured refractive indices are almost independent of the glass composition. We show that third-order nonlinear optical susceptibilities calculated from the measured refractive indices using Lines' theoretical model are also independent of the glass composition.
Resumo:
In this second part it will be discussed some photonic applications of glassy and glass ceramic thin films which can be used as planar waveguides. Some photonic applications require certain specifications of glass, which can be quantified by studying the nonlinear optical properties of the materials. Therefore, a brief introduction of these phenomena is discussed, as well as the use of femtosecond lasers to manipulate the composition or for the preparation of waveguides into glasses. Finally, the article will address a brief introduction on microstructured optical fibers and commercial application prospects for these devices.
Resumo:
The immune response expressed by IgG antibodies in BALB/c mice experimentally infected with Toxocara canis, was studied with the aim of verifying the possible in vivo cross-reactivity between antigens of T. canis and other parasites (Ascaris suum, Taenia crassiceps, Schistosoma mansoni, Strongyloides venezuelensis and Toxoplasma gondii). Experiments included three groups of mice: one infected only by T. canis, another with one of the other species of parasites and a third concomitantly infected with T. canis and the other species in question. Animals were bled by orbital plexus at 23, 38 and 70 days post infection (p.i.). Sera were analyzed for anti-Toxocara antibodies by ELISA and Immunoblotting, using excretion-secretion antigens (ES), obtained from culture of third-stage larvae of T. canis. For all experiments a control group comprised by ten non-infected mice was used. Only in the case of A. suum infection, in these experimental conditions, the occurrence of cross-reactivity with T. canis was observed. However, in the case of co-infection of T. canis - S. mansoni, T. canis - S. venezuelensis and T. canis - T. crassiceps the production of anti-Toxocara antibodies was found at levels significantly lower than those found in mice infected with T. canis only. Co-infection with S. mansoni or S. venezuelensis showed lower mortality rates compared to what occurred in the animals with single infections. Results obtained in mice infected with T. canis and T. gondii showed significant differences between the mean levels of the optical densities of animals infected with T. canis and concomitantly infected with the protozoan only in the 23rd day p.i.
Resumo:
We have studied the cardiac chronotropic responses to the Valsalva maneuver and to dynamic exercise of twenty chronic chagasic patients with normal left ventricular function and no segmental wall abnormalities by two-dimensional echocardiogram. The absolute increase in heart rate of the patients (Δ = 21.5 ± 10 bpm, M±SD) during the maneuver was significantly diminished when compared to controls (Δ = 31.30 ± 70, M±SD, p = 0.03). The minimum heart rate (58.24 ± 8.90 vs. 62.80 ± 10, p = 0.68) and the absolute decrease in heart rate at the end of the maneuver (Δ = 38.30 ± 13 vs. Δ = 31.47 ± 17, p = 0.10) were not different from controls. The initial heart rate acceleration during dynamic exercise (Δ = 12 ± 7.55 vs. Δ = 19 ± 7.27, M±SD, p = 0.01) was also diminished, but the heart rate recovery during the first ten seconds was more prominent in the sero-positive patients (Median: 14, Interquartile range: (9.75-17.50 vs. 5(0-8.75, p = 0.001). The serum levels of muscarinic cardiac auto-antibodies were significantly higher in the chagasic patients (Median: 34.58, Interquartile Range: 17-46.5, Optical Density) than in controls (Median: 0, Interquartile Range: 0-22.25, p = 0.001) and correlated significantly and directly (r = 0.68, p = 0.002) with early heart rate recovery during dynamic exercise. The results of this investigation indirectly suggest that, the cardiac muscarinic auto-antibodies may have positive agonist effects on parasympathetic heart rate control of chagasic patients.
Resumo:
An optical chemical sensor for the determination of nitrite based on incorporating methyltrioctylammonium chloride as an anionic exchanger on the triacetylcellulose polymer has been reported. The response of the sensor is based on the redox reaction between nitrite in aqueous solution and iodide adsorbed on sensing membrane using anion exchange phenomena. The sensing membrane reversibly responses to nitrite ion over the range of 6.52×10-6 - 8.70×10-5 mol L-1 with a detection limit of 6.05×10-7 mol L-1 (0.03 µg mL-1) and response time of 6 min. The relative standard deviation for eight replicate measurements of 8.70×10-6 and 4.34×10-5 mol L-1 of nitrite was 4.4 and 2.5 %, respectively. The sensor was successfully applied for determination of nitrite in food, saliva and water samples.