29 resultados para NICKEL-TITANIUM INSTRUMENTS
em Scielo Saúde Pública - SP
Resumo:
A spectrophotometric method was proposed for Ni(II) determination in alloys using a dopa-semiquinone (L-1) to form [Ni(II)(L1-)3]1-, ε = 9.3 x 10³ L mol-1 cm-1. The optimal conditions for the determination were: wavelength 590 nm, temperature 25 °C, reaction time 45 min and pH 7.5. The Beer's law was obeyed for nickel from 3.33 x 10-5 to 1.78 x 10-4 mol L-1. The method was applied to complex samples, such as inox, nickel-titanium and cobalt-chromium alloys. A study of the potential interferents revealed that Mn was the major interferent. The limit of detection and quantification were 2.88 x 10-5 mol L-1 and 3.06 x 10-5 mol L-1, respectively.
Resumo:
This work consists in an evaluation of the occurrence of nickel contact dermatitis, its distribution between sexes and in which parts of the body the dermatitis usually occurs. It was accomplished a two year (1994-1995) retrospective study of 404 patch-tested patients which had previous clinical diagnosis of contact dermatitis. The occurrence of nickel sensitisation was 19,8%. 88,8% of these 19,8% were women and the rest, 11,2%, were men. The lesions were present predominantly on hands, forearms, earlobes and feet. The authors comment about possible variations of occurrence of nickel contact dermatitis in rural areas and/or tropical countries
Resumo:
We analyzed 37 patients who underwent segmental wide resection of bone tumors and reconstruction with a modular titanium endoprosthesis at the Orthopaedic Oncology Group, between 1992 and 1998. Twelve patients were male and 25 were female, with a mean age of 30 years (9 - 81). The mean follow-up was 14 months (2 - 48). The diagnoses were: osteosarcoma (14 cases), metastatic carcinoma (10), Ewing's sarcoma (4), giant cell tumor (4), malignant fibrous histiocytoma (3), chondrosarcoma (1), and aneurysmal bone cyst (1). Eleven articulated total knee, 8 partial proximal femur with bipolar acetabulum, 8 partial proximal humerus, 3 total femur, 2 partial proximal tibia, 2 diaphyseal femur, 2 diaphyseal humerus, and 1 total proximal femur with cementless acetabulum endoprosthesis implant procedures were done. The complications related to the procedure included: infection (5 cases), dislocation (3), module loosening (1), and ulnar nerve paresthesia (1). We used the following criteria for the clinical evaluation: presence of pain, range of motion, reconstruction stability, surgical and oncologic complications, and patient acceptance. The results were good in 56.8% of the cases, regular in 32.4% and poor in 10.8%.
Resumo:
The aim of this report is to describe the anatomic-pathologic findings from necropsies of 5 drug addicts with titanium pigment in several organs after chronic intravenous injection of crushed propoxyphene hydrochloride tablets. Samples from liver, spleen, lungs, lymph nodes, and bone marrow were obtained, and after being grossly studied, they were submitted to evaluation using common light and polarized microscopy. In all 5 cases, a pigment with characteristics of titanium dioxide was found within tissue samples of the organs studied. Our findings suggest that research concerning titanium pigment within body tissues should be enhanced, considering the potential contribution of this morphologic data to forensic pathology.
Resumo:
Objective To systematically review the scientific literature on the psychometric properties of international instruments for the assessment of autism spectrum disorder (ASD) in the Brazilian population. Methods A search of bibliographic references was conducted in six electronic databases: PsycINFO, PubMed, IndexPsi, Lilacs, Capes (theses and dissertations) and SciELO. The studies were selected by two independent researchers. Results The procedure identified 11 studies of the Brazilian population that encompassed six ASD assessment tools. Given the information provided, the adaptation of the M-CHAT, a screening instrument, was the best conducted. All steps of the adaptation process were described and the changes made to the final version of the instrument were presented, which was not addressed in other studies. In terms of reliability, all of the instruments that assessed internal consistency showed adequate values. In addition, the ADI-R and the CARS adaptations also satisfactorily contemplated inter-rater reliability and test-retest indices, respectively. Finally, all studies aiming to validate instruments showed evidence of validity and sensitivity, and specificity values above 0.90 were observed in the ASQ, ADI-R and ABC. Conclusion Considering both the psychometric aspects and the copyright information, the screening instrument that currently appears to be best indicated for clinical and research use is the M-CHAT. It was also noticed that there are still no specific ASD diagnostic tools available for use in Brazil. This lack of diagnostic instruments consists in a critical situation for the improvement of clinical practice and the development of research in this area.
Resumo:
Objective This study describes the development of two updating measures of working memory (WM): Letter Updating Test (LUT) and Word Updating Test (WUT). Methods In stage 1, items were created and the instruments were assessed by experts and laymen. In stage 2, tests were given to 15 patients with schizophrenia and 15 paired controls. All were able to understand and respond to the instruments. In stage 3, 141 patients with schizophrenia and 119 healthy controls aged 18 to 60 took part; they were assessed on WM, processing speed (PS) and functional outcome. Results The results showed adequate rates of internal consistency for both measures developed, for both the total sample and each group separately, as well as evidence of convergent validity, discriminant validity and sensitivity to differentiate performance among the groups. Principal component analysis yielded two components, one for updating tests and other for PS measures, indicating factorial validity. Positive and significant, yet low, correlations were found with functionality measures. Conclusion These results provide adequate psychometric parameters for the measures developed, applicable to cognitive research settings in schizophrenia.
Resumo:
This was a systematic review aimed at identifying and characterizing measuring instruments, developed in the context of cardiology, which were adapted into Portuguese language of Brazil. Systematic searches were performed in six databases. Information extracted included cultural adaptation process and measurement properties. To assess the methodological quality of studies, criteria based on international guidelines for cultural adaptation of instruments were used. Among the 114 articles found, 14 were eligible for review. Of these, most evaluated quality of life (35.7%) and health knowledge/learning (28.6%). Most studies followed all stages of the adaptation process recommended in the literature. With respect to measurement properties, internal consistency, verified by Cronbach’s alpha, was the property reported in the majority of the studies, as well as construct and criterion validity. This study is expected to provide to the scientific community a critical evaluation of adapted questionnaires available in the context of cardiology.
Resumo:
Objective To identify the characteristics of managers and their use of management instruments in primary care and to analyze differences in these features among municipalities of different sizes. Method The present cross-sectional descriptive study was conducted at 108 basic health units from 21 municipalities in northern Paraná, Brazil. The data were collected using a semi-structured questionnaire during the second half of 2010. Results Most managers had graduate degrees and were female and nurses. The managers from the small municipalities were younger, their payment was lower, and they had less work experience. The use of management instruments was expressive for both the organization and work management; however, the instruments were used less in the small municipalities. Conclusion The managers were committed to their role; it is recommended that policies and guidance should be formulated at the federal and state levels to support small municipalities.
Resumo:
Objective To analyze the production of scientific knowledge about the use of patients’ classification instruments in care and management practice in Brazil. Method Integrative literature review with databases search in: Latin American and Caribbean Literature on Health Sciences (LILACS), Medical Literature Analysis and Retrieval System on-line (MEDLINE), Cumulative Index to Nursing and Allied Health Literature (CINAHL) and SCOPUS, between January 2002 through December 2013. Results 1,194 studies were found, 31 met the inclusion criteria. We observed a higher number of studies in the category care plans and workload (n=15), followed by the category evaluation of psychometric properties (n=14). Conclusion Brazilian knowledge production has not yet investigated some purposes of using instruments for classifying patients in professional nursing practice. The identification of unexplored areas can guide future research on the topic.
Resumo:
In order to investigate the efficiency of sulfate green rust (GR2) to remove Ni from solution, GR2 samples were synthesized under controlled laboratory conditions. Some GR2 samples were synthesized from Fe(II) and Fe(III) sulfate salts by precipitation. Other samples were prepared by coprecipitation, of Ni(II), Fe(II) and Fe(III) sulfate salts, i.e., in the presence of Ni. In another sample, Ni(II) sulfate salt was added to pre-formed GR2. After an initial X-ray diffraction (XRD) characterization all samples were exposed to ambient air in order to understand the role of Ni in the transformation of the GR2 samples. XRD was repeated after 45 days. The results showed that Nious GR2 prepared by coprecipitation is isomorphous to Ni-free GR2, i.e. Ni is incorporated into the crystalline structure. Fe(II) was not replaced by Ni(II) in the crystalline structure of GR2 formed prior to exposure to solution-phase Ni. This suggests Ni was adsorbed to the GR2 surface. Sulfate green rust is more efficient in removing Ni from the environment by coprecipitation.
Resumo:
Ni(II)-Fe(II)-Fe(III) layered double hydroxides (LDH) or Ni-containing sulfate green rust (GR2) samples were prepared from Ni(II), Fe(II) and Fe(III) sulfate salts and analyzed with X ray diffraction. Nickel is readily incorporated in the GR2 structure and forms a solid solution between GR2 and a Ni(II)-Fe(III) LDH. There is a correlation between the unit cell a-value and the fraction of Ni(II) incorporated into the Ni(II)-GR2 structure. Since there is strong evidence that the divalent/trivalent cation ratio in GR2 is fixed at 2, it is possible in principle to determine the extent of divalent cation substitution for Fe(II) in GR2 from the unit cell a-value. Oxidation forms a mixture of minerals but the LDH structure is retained if at least 20 % of the divalent cations in the initial solution are Ni(II). It appears that Ni(II) is incorporated in a stable LDH structure. This may be important for two reasons, first for understanding the formation of LDHs, which are anion exchangers, in the natural environment. Secondly, this is important for understanding the fate of transition metals in the environment, particularly in the presence of reduced Fe compounds.
Resumo:
Nickel, although essential to plants, may be toxic to plants and animals. It is mainly assimilated by food ingestion. However, information about the average levels of elements (including Ni) in edible vegetables from different regions is still scarce in Brazil. The objectives of this study were to: (a) evaluate and optimize a method for preparation of vegetable tissue samples for Ni determination; (b) optimize the analytical procedures for determination by Flame Atomic Absorption Spectrometry (FAAS) and by Electrothermal Atomic Absorption (ETAAS) in vegetable samples and (c) determine the Ni concentration in vegetables consumed in the cities of Lorena and Taubaté in the Vale do Paraíba, State of São Paulo, Brazil. By means of the analytical technique for determination by ETAAS or FAAS, the results were validated by the test of analyte addition and recovery. The most viable method tested for quantification of this element was HClO4-HNO3 wet digestion. All samples but carrot tissue collected in Lorena contained Ni levels above the permitted by the Brazilian Ministry of Health. The most disturbing results, requiring more detailed studies, were the Ni concentrations measured in carrot samples from Taubaté, where levels were five times higher than permitted by Brazilian regulations.
Resumo:
Nickel is a micronutrient involved in nitrogen metabolism and a constituent of the urease molecule. Plant growth and urease activity were evaluated in lettuce (Lactuca sativa L.) grown in soil-filled pots in a 2 x 8 factorial design with two nitrogen (N) sources and eight Ni rates, with five replications. Nitrogen was applied at 200 mg dm-3 (half the dose incorporated into the soil at seedling transplanting and half top-dressed later) using the sources NH4NO3 (AN) and CO(NH2)2 (Ur). The Ni treatments (0, 2, 4, 8, 12, 16, 24 and 32 mg dm-3) were applied as NiCl2. The shoot dry-matter yield, leaf urease activity, Ni levels in the lettuce leaves and Ni levels extracted from soil with Mehlich-3 (M-3) and DTPA were determined. In the plants supplied with AN, the shoot dry-matter yield was higher than in those supplied with Ur. There was no difference in shoot dry matter in response to soil-applied Ni. The leaf urease activity increased with Ni application, regardless of the N source. The extractions with M-3 and DTPA were efficient to evaluate Ni availability for lettuce in the Red-Yellow Latosol.
Resumo:
There are currently many devices and techniques to quantify trace elements (TEs) in various matrices, but their efficacy is dependent on the digestion methods (DMs) employed in the opening of such matrices which, although "organic", present inorganic components which are difficult to solubilize. This study was carried out to evaluate the recovery of Fe, Zn, Cr, Ni, Cd and Pb contents in samples of composts and cattle, horse, chicken, quail, and swine manures, as well as in sewage sludges and peat. The DMs employed were acid digestion in microwaves with HNO3 (EPA 3051A); nitric-perchloric digestion with HNO3 + HClO4 in a digestion block (NP); dry ashing in a muffle furnace and solubilization of residual ash in nitric acid (MDA); digestion by using aqua regia solution (HCl:HNO3) in the digestion block (AR); and acid digestion with HCl and HNO3 + H2O2 (EPA 3050). The dry ashing method led to the greatest recovery of Cd in organic residues, but the EPA 3050 protocol can be an alternative method for the same purpose. The dry ashing should not be employed to determine the concentration of Cr, Fe, Ni, Pb and Zn in the residues. Higher Cr and Fe contents are recovered when NP and EPA 3050 are employed in the opening of organic matrices. For most of the residues analyzed, AR is the most effective method for recovering Ni. Microwave-assisted digestion methods (EPA3051 and 3050) led to the highest recovery of Pb. The choice of the DM that provides maximum recovery of Zn depends on the organic residue and trace element analyzed.
Resumo:
In comparison with other micronutrients, the levels of nickel (Ni) available in soils and plant tissues are very low, making quantification very difficult. The objective of this paper is to present optimized determination methods of Ni availability in soils by extractants and total content in plant tissues for routine commercial laboratory analyses. Samples of natural and agricultural soils were processed and analyzed by Mehlich-1 extraction and by DTPA. To quantify Ni in the plant tissues, samples were digested with nitric acid in a closed system in a microwave oven. The measurement was performed by inductively coupled plasma/optical emission spectrometry (ICP-OES). There was a positive and significant correlation between the levels of available Ni in the soils subjected to Mehlich-1 and DTPA extraction, while for plant tissue samples the Ni levels recovered were high and similar to the reference materials. The availability of Ni in some of the natural soil and plant tissue samples were lower than the limits of quantification. Concentrations of this micronutrient were higher in the soil samples in which Ni had been applied. Nickel concentration differed in the plant parts analyzed, with highest levels in the grains of soybean. The grain, in comparison with the shoot and leaf concentrations, were better correlated with the soil available levels for both extractants. The methods described in this article were efficient in quantifying Ni and can be used for routine laboratory analysis of soils and plant tissues.