Resumo:
OBJECTIVE To validate a screening instrument using self-reported assessment of frailty syndrome in older adults.METHODS This cross-sectional study used data from the Saúde, Bem-estar e Envelhecimento study conducted in Sao Paulo, SP, Southeastern Brazil. The sample consisted of 433 older adult individuals (≥ 75 years) assessed in 2009. The self-reported instrument can be applied to older adults or their proxy respondents and consists of dichotomous questions directly related to each component of the frailty phenotype, which is considered the gold standard model: unintentional weight loss, fatigue, low physical activity, decreased physical strength, and decreased walking speed. The same classification proposed in the phenotype was utilized: not frail (no component identified); pre-frail (presence of one or two components), and frail (presence of three or more components). Because this is a screening instrument, “process of frailty” was included as a category (pre-frail and frail). Cronbach’s α was used in psychometric analysis to evaluate the reliability and validity of the criterion, the sensitivity, the specificity, as well as positive and negative predictive values. Factor analysis was used to assess the suitability of the proposed number of components.RESULTS Decreased walking speed and decreased physical strength showed good internal consistency (α = 0.77 and 0.72, respectively); however, low physical activity was less satisfactory (α = 0.63). The sensitivity and specificity for identifying pre-frail individuals were 89.7% and 24.3%, respectively, while those for identifying frail individuals were 63.2% and 71.6%, respectively. In addition, 89.7% of the individuals from both the evaluations were identified in the “process of frailty” category.CONCLUSIONS The self-reported assessment of frailty can identify the syndrome among older adults and can be used as a screening tool. Its advantages include simplicity, rapidity, low cost, and ability to be used by different professionals.
Resumo:
OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.